Table 5-14. racadm Command Options (continued)

Option

Description

 

 

-S

Specifies that RACADM should check for invalid

 

certificate errors. RACADM stops the execution of the

 

command with an error message if it detects an invalid

 

certificate.

 

 

Enabling and Disabling the RACADM Remote Capability

NOTE: It is recommended that you run these commands on your local system.

The RACADM remote capability is enabled by default. If disabled, type the following RACADM command to enable:

racadm config -g cfgRacTuning -o cfgRacTuneRemoteRacadmEnable 1

To disable the remote capability, type:

racadm config -g cfgRacTuning -o cfgRacTuneRemoteRacadmEnable 0

RACADM Subcommands

Table 5-15 provides a description of each RACADM subcommand that you can run in RACADM. For a detailed listing of RACADM subcommands, including syntax and valid entries, see the iDRAC6 Administrator Reference Guide available on the Dell Support website at support.dell.com/manuals.

When entering a RACADM subcommand, prefix the command with racadm, for example:

racadm help