racadm config -g cfgIpmiSol -o cfgIpmiSolEnable 1

aUpdate the IPMI SOL minimum privilege level.

NOTE: The IPMI SOL minimum privilege level determines the minimum privilege required to activate IPMI SOL. For more information, see the IPMI 2.0 specification.

At the command prompt, type the following command and press <Enter>:

racadm config -g cfgIpmiSol -o cfgIpmiSolMinPrivilege <level>

where <level> is one of the following:

2 (User)

3 (Operator)

4 (Administrator)

For example, to configure the IPMI privileges to 2 (User), type the following command:

racadm config -g cfgIpmiSol -o cfgIpmiSolMinPrivilege 2

bUpdate the IPMI SOL baud rate.

NOTE: To redirect the serial console over LAN, ensure that the SOL baud rate is identical to your managed system’s baud rate.

At the command prompt, type the following command and press <Enter>:

racadm config -g cfgIpmiSol -o cfgIpmiSolBaudRate <baud_rate>

where <baud_rate> is 9600, 19200, 57600, or 115200 bps.

For example:

racadm config -g cfgIpmiSol -o cfgIpmiSolBaudRate 57600

cEnable SOL for an individual user.

Configuring Intelligent Platform Management Interface