fEnsure that the serial MUX is set correctly in the managed system’s BIOS Setup program.

Restart your system.

During POST, press <F2> to enter the BIOS Setup program.

Navigate to Serial Communication.

In the Serial Connection menu, ensure that External Serial Connector is set to Remote Access Device.

Save and exit the BIOS Setup program.

Restart your system.

If IPMI serial is in terminal mode, you can configure the following additional settings:

Delete control

Echo control

Line edit

New line sequences

Input new line sequences

For more information about these properties, see the IPMI 2.0 specification. For additional information about terminal mode commands, see the Dell OpenManage Baseboard Management Controller Utilities User’s Guide at support.dell.com/manuals.

Configuring iDRAC6 Users

See "Adding and Configuring iDRAC6 Users" on page 129 for detailed information.

Configuring the iDRAC6 Using the Web Interface