Table 4-31. IDSDM Status

IDSDM - Mirror

SD1 Card

SD2 Card

vFlash SD Card

Mode

 

 

 

 

 

 

 

Enabled

Active

Active

Inactive

Disabled

Active

Inactive

Active

 

 

 

 

Using iDRAC you can view the status, health, and availability of IDSDM.

The SD card redundancy status and failure events are logged to SEL, displayed on LCD, and PET alerts are generated if alerts are enabled.

Viewing Internal Dual SD Module Status Using GUI

1Log in to the iDRAC Web GUI.

2Click Removable Flash Media. The Removable vFlash Media page is displayed. This page displays the following two sections:

Internal Dual SD Module — Displayed only if IDSDM is in redundant mode. The Redundancy Status is displayed as Full. If this section is not present, then the card is in the non-redundant mode state. The valid Redundancy Status indications are:

Full — SD card 1 and 2 are functioning properly.

Lost — Either one of the SD card or both the SD cards are not functioning properly.

Internal SD Module Status — Displays the SD card state for SD1, SD2, and vFlash cards with the following information:

Status:

— Indicates that the card is ok.

— Indicates that the card is offline or write-protected.

— Indicates that an alert is issued.

Location — Location of the SD cards.

Online Status — SD1, SD2, and vFlash cards can be in one of the states listed in Table 4-32.

Configuring the iDRAC6 Using the Web Interface

85

Page 85
Image 85
Dell IDRAC6 manual Viewing Internal Dual SD Module Status Using GUI