NOTE: SOL can be enabled or disabled for each individual user.

At the command prompt, type the following command and press <Enter>:

racadm config -g cfgUserAdmin -o cfgUserAdminSolEnable -i <id> 2

where <id> is the user’s unique ID.

4Configure IPMI Serial.

aChange the IPMI serial connection mode to the appropriate setting.

At the command prompt, type the following command and press <Enter>:

racadm config -g cfgSerial -o cfgSerialConsoleEnable 0

bSet the IPMI Serial baud rate.

Open a command prompt, type the following command, and press <Enter>:

racadm config -g cfgIpmiSerial -o cfgIpmiSerialBaudRate <baud_rate>

where <baud_rate> is 9600, 19200, 57600, or 115200 bps. For example:

racadm config -g cfgIpmiSerial -o cfgIpmiSerialBaudRate 57600

cEnable the IPMI serial hardware flow control.

At the command prompt, type the following command and press <Enter>:

racadm config -g cfgIpmiSerial -o cfgIpmiSerialFlowControl 1

252

Configuring Intelligent Platform Management Interface

Page 252
Image 252
Dell IDRAC6 manual 252