106 Advanced iDRAC6 Configuration
Configuring Serial and Terminal Modes

Configuring IPMI and iDRAC6 Serial

1
Expand the
System
tree and click
Remote Access
.
2
Click the
Network/Security
tab and then click
Serial
.
3
Configure the IPMI serial settings.
See Table5-8 for description of the IPMI serial settings.
4
Configure the iDRAC6 serial settings.
See Table5-9 for description of the iDRAC6 serial settings.
5
Click
Apply Changes
.
6
Click the appropriate
Serial
page button to continue. See Table5-10 for
description of the serial configuration page settings.
Table 5-7. Management Station COM Port Settings
Setting Description Required Setting
Bits per second 57600
Data bits 8
Parit y None
Stop bits 1
Flow control Hardware
Table 5-8. IPMI Serial Settings
Setting Description
Connection Mode
Settings
• Direct Connect Basic Mode - IPMI Ser ial Basic Mode
• Direct Connect Terminal Mode - IPMI Serial Terminal Mode
Baud Rate
• Sets the data speed rate. Select
9600 bps
,
19.2 kbps
,
57.6kbps
,
or
115.2kbps
.