Generac 101 9-3 operating instructions Before Starting the Engine, Add Fuel, Add Engine Oil

Page 8

7500EXL Extended Life Generator

BEFORE STARTING THE ENGINE

Add Fuel

NOTE: This gasoline engine is certified to operate on

gasoline. Exhaust Emission Control System: EM (Engine Modifications).

Add Engine Oil

• Place generator on a level surface.

CAUTION

Any attempt to crank or start the engine before it has been properly filled with the recommended oil will result in equipment failure.

Refer to engine manual for oil fill information.

Damage to equipment resulting from failure to follow this instruction will void warranty.

Refer to engine operator’s manual and follow oil recommendations and instructions.

NOTE: Check oil often during engine break–in. Refer to engine operator’s manual for recommendations.

NOTE: The generator assembly rotates on a prelubricated and sealed ball bearing that requires no additional lubrication for the life of the bearing.

WARNING

Fuel and its vapors are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

WHEN ADDING FUEL

Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

Fill fuel tank outdoors.

DO NOT overfill tank. Allow space for fuel expansion.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

DO NOT light a cigarette or smoke.

1.Use clean, fresh, regular UNLEADED fuel with a minimum of 85 octane. DO NOT use fuel which contains Methanol. DO NOT mix oil with fuel.

2.Clean area around fuel fill cap, remove cap.

3.Slowly add regular unleaded fuel to fuel tank. Be careful not to overfill. Allow at least 1.5" of tank space for fuel expansion (Figure 3).

Figure 3 - Fuel Expansion

 

AirSpace

Tank

 

 

 

Fuel

 

1.5”

 

 

 

 

4.

Install fuel cap and wipe up any spilled fuel.

 

8

Image 8
Contents Operator’s Manual Call Generac Generator Helpline 1-800-270-1408 M-F8-5 CTEquipment Description Table of ContentsSafety Rules Generator produces powerful voltage Unintentional sparking can result in fire or electric shock Know Your Generator Assembly Carton ContentsInstall Wheel Kit Unpack the GeneratorCheck Battery / Attach Negative Battery Wire To installAdd Engine Oil Before Starting the EngineAdd Fuel Using the Generator Connecting to a Building’s Electrical SystemSystem Ground Generator LocationConnecting Electrical Loads Operating the GeneratorStarting the Engine Do not Overload the GENERATOR. See Don’t Overload GeneratorCharging a Battery Stopping the EngineOperating Automatic Idle Control To recharge 12 Volt batteries, proceed as followsHow to Use the Battery Charger Cold Weather OperationCreating a Temporary Shelter Creating a Permanent ShelterGenerator Adapter Cord SET ReceptaclesVolt DC, 10 Amp Receptacle Volt AC, 20 Amp, Duplex Receptacle120/240 Volt AC, 30 Amp, Locking Receptacle 120/240 Volt AC, 50 Amp ReceptaclePower Management Dont Overload GeneratorCapacity ExampleSpecifications General Maintenance RecommendationsStorage Generator StorageEngine Storage Other Storage TipsTroubleshooting About your equipment warranty Effective November 1

101 9-3 specifications

The Generac 101 9-3 is a cutting-edge power generation solution designed to meet the diverse needs of both residential and commercial users. Renowned for its robust construction and innovative technologies, this unit stands out in the competitive market of backup generators.

At the heart of the Generac 101 9-3 is its powerful engine, capable of delivering reliable performance in any situation. This generator boasts a high-output capacity, ensuring that it can handle multiple appliances simultaneously during outages. It is particularly well-suited for larger homes and businesses that depend on a steady power supply for critical operations.

One of the main features of the Generac 101 9-3 is its automatic transfer switch (ATS). This technology allows the generator to detect power outages and switch on automatically, ensuring minimal disruption. The ATS guarantees that the transition from grid power to generator power is seamless and instantaneous, providing peace of mind for users.

The unit also showcases a user-friendly control panel with intuitive interfaces, making it easy to monitor performance and adjust settings. Generac has integrated advanced monitoring capabilities, allowing users to track fuel levels, power output, and maintenance schedules. This feature enhances the convenience of ownership and prolongs the lifespan of the generator.

Another remarkable characteristic of the Generac 101 9-3 is its emissions control technology. Designed to meet stringent environmental regulations, this generator operates efficiently while minimizing its carbon footprint. The low-emission engine is a testament to Generac’s commitment to sustainable energy solutions.

In terms of durability, the Generac 101 9-3 is built to withstand harsh weather conditions. Housed in a weatherproof enclosure, it is protected from rain, snow, and extreme temperatures, ensuring reliability in any climate. Its heavy-duty construction provides the longevity needed for prolonged use, making it a worthwhile investment.

Additionally, the Generac 101 9-3 is designed with serviceability in mind. It comes equipped with easily accessible components, simplifying maintenance and repair tasks. This thoughtful design feature helps reduce downtime and keeps the generator running at peak performance.

In conclusion, the Generac 101 9-3 is a high-performance generator that combines power, efficiency, and durability. Its automatic transfer switch, advanced monitoring, emissions control technology, and user-friendly design make it an excellent choice for anyone in need of a reliable power backup solution. Whether for home or business use, the Generac 101 9-3 stands ready to deliver dependable energy when it’s needed most.