Generac 00784-2, 09290-4 owner manual General Hazards

Page 20

Safety Rules

PRIMEPACT 50 and 70 (50Hz) Recreational Vehicle Generators

DANGER: For fire safety, installation of a generator into a recreational vehicle must comply strictly with article 551, NFPA 70; ANSI C1-1975; AND, ANSI A119.2-1975/NFPA 501C “Standard for Recreational Vehicles” (Part 3, “Installation of Electrical Systems”). In addition, installation must comply with the manufacturer’s instructions and recommendations.

NOTICE TO INSTALLER

These Installation Instructions have been published by Generac to aid in the installation of the products described in this manual. Generac assumes that installation personnel are familiar with the proce- dures for installing such products, or similar prod- ucts that Generac manufactures. Generac also assumes that personnel have been trained in the rec- ommended installation procedures for these prod- ucts and that such training includes (a) use of com- mon hand tools, (b) use of special Generac tools, and

(c)use of any tools and/or equipment from other sup- pliers.

Generac cannot possibly know of and advise the recreational vehicle trade of all conceivable methods, procedures or techniques by which to perform an installation. Nor can Generac anticipate every possi- ble hazard that might result from each installation method, procedure or technique. Generac has not undertaken any such wide evaluation. Therefore, people who use a method, procedure or technique that Generac does not specifically recommend must first completely satisfy themselves that their safety, the safety of the vehicle's occupants and the product's safety is not endangered by the method, procedure or technique selected.

Information, illustrations, specifications, etc., con- tained in these Installation Instructions are based on the latest information available at the time of publi- cation. Every effort has been expended to be sure that such data is both accurate and current. However, the manufacturer reserves the right to change, alter or otherwise improve this product at any time without prior notice.

Despite the safe design of this generator, operating this equipment imprudently, neglecting its maintenance or being careless can cause possible injury or death. Permit only responsible and capable persons to operate or maintain this equipment.

Potentially lethal voltages are generated by these machines. Ensure all steps are taken to render the machine safe before attempting to work on the generator.

Parts of the generator are rotating and/or hot during operation. Exercise care near running generators.

GENERAL HAZARDS

For safety reasons, Generac recommends that the installation, initial start-up and mainte- nance of this equipment is carried out by a Generac Authorized Service Dealer.

The engine exhaust fumes contain carbon monox- ide, which can be DEADLY. This dangerous gas, if breathed in sufficient concentrations, can cause unconsciousness or even death. This exhaust sys- tem must be installed properly, in strict compli- ance with applicable codes and standards. Following installation, you must do nothing that might render the system unsafe or in noncompli- ance with such codes and standards. The genera- tor compartment must be completely vapor sealed from the vehicle interior. There must be no possi- bility of exhaust fumes entering the vehicle interi- or. Never operate this equipment with a leaking or defective exhaust system.

Keep hands, feet, clothing, etc., away from drive belts, fans, and other moving or hot parts. Never remove any drive belt or fan guard while the unit is operating.

Adequate, unobstructed flow of cooling and venti- lating air is critical to correct generator operation and is required to expel toxic fumes and fuel vapors from the generator compartment. Without sufficient cooling airflow, the engine/generator quickly overheats, which causes serious damage to the generator. Do not alter the installation or per- mit even partial blockage of ventilation provisions, as this can seriously affect safe operation of the generator.

When working on this equipment, remain alert at all times. Never work on the equipment when you are physically or mentally fatigued.

Before performing any maintenance on the genera- tor, disconnect its battery cables to prevent acci- dental start up. Disconnect the cable from the bat- tery post indicated by a NEGATIVE, NEG or (–) first. Reconnect that cable last.

Never use the generator or any of its parts as a step. Stepping on the unit can stress and break parts, and may result in dangerous operating con- ditions from leaking exhaust gases, fuel leakage, oil leakage, etc.

Never insert any tool or other object through open- ings in the generator interior, even if the unit is not running. You might seriously injure yourself or damage the equipment.

18 Generac® Power Systems, Inc.

Image 20
Contents Power SYSTEMS, INC Authorized Service Dealer Location IntroductionTable of Contents General Hazards Electrical Hazards Generator Identification Reference Number IdentificationInstallation SafetyGenerator Applicability Generator AC Connection SystemSpecifications Fuel RequirementsEngine Generator PP50G/PP70GAutomatic Choke Generator Control PanelOptional Remote START/STOP Panel Before Starting the Engine Starting the GeneratorStopping the Generator Protection SystemsAdditional Information Overvoltage Protection1 25-HOUR BREAK-IN Period 2 25-HOUR CHECK-UPChecking the Engine OIL Level Changing the Engine OIL AND/OR OIL FilterMaintaining the Engine AIR Cleaner Clean AIR Intake ScreenCleaning the Foam Precleaner Checking the Engine Spark PlugCleaning the Generator Battery MaintenanceSpark Arrestor Muffler WeeklyOUT of Service Procedure Removal from ServiceDrive Belt Exercising the GeneratorReturn to Service Wattage Reference GuidePrimepact 50 and 70 50Hz Recreational Vehicle Generators Part General Hazards Electrical Hazards Purpose and Scope Manual Equipment DescriptionGenerator Engine Operating Speed Standards BookletsPrimePact 50 Location and Support Generator LocationGenerator Support Suspended MountingGenerator Compartments Generator RestraintCompartment Construction Compartment SizeAcoustics Sound Insulating MaterialsCompartment Floor Cutouts Typical Noise AbatementCooling AIR Inlet Openings Cooling and Ventilating AIRGenerator Airflow Compensating for Restrictions Testing the InstallationGasoline Fuel System Exhaust System Fuel Tank Flexible Fuel LineGenerator Fuel Supply Line Rigid Fuel LinesExhaust System Safety Electrical ConnectionsMufflers and Spark Arrestors Type of Exhaust SystemIsolating Different Power Sources Power Supply CordGround Fault Circuit Inter Rupters Generator AC Connections18 Transfer Switch Isolation Method Optional Accessories Recommended BatteryBattery Cables Battery Cable ConnectionsPost Installation Tests Testing Under LoadBefore Initial START-UP Initial StartInstallation Checklist Troubleshooting Guide Problem Cause CorrectionElectrical Data Electrical Data Exploded Views and Parts Lists QTY Description Exploded Views and Parts Lists Lower Bearing Carrier Exploded Views and Parts Lists Bevelled Washer Exploded Views and Parts Lists Cylinder Assembly Exploded Views and Parts Lists Carburetor Assemby PURCHASER’S/OWNER’S Warranty Responsibilities Your Warranty Rights and ObligationsMANUFACTURER’S Emission Control System Warranty Coverage Emission Control System Warranty Emission Related Parts Include the FollowingRevised 10/05/01

00784-2, 09290-4 specifications

Generac is a prominent name in the power equipment industry, known for its reliable backup generators and innovative solutions. Among its impressive lineup are models like the Generac 00784-2 and the 09290-4, both designed to provide dependable performance for a variety of applications.

The Generac 00784-2 is a versatile portable inverter generator that stands out for its quiet operation and efficient power output. With a peak wattage of 3,300 watts and a running wattage of 2,600 watts, this generator is perfect for camping trips, tailgating, or as a backup power source during emergencies. One of the defining features of the 00784-2 is its TruePower Technology, which produces clean and stable power suitable for sensitive electronics such as laptops and smartphones. Additionally, its economy mode helps optimize fuel efficiency, allowing users to extend runtime while minimizing noise levels.

Weighing only 46 pounds, the 00784-2 is designed for mobility. Its compact design and integrated handle make transport and storage a breeze. The generator also features a built-in fuel gauge, enabling users to easily monitor fuel levels, and its easily accessible control panel allows for user-friendly operation.

On the other hand, the Generac 09290-4 is a powerful stationary generator aimed at providing robust backup power for homes and small businesses. With a 10,000-watt output, the 09290-4 can seamlessly power essential appliances during power outages, ensuring comfort and safety. This model features an automatic transfer switch, which detects power outages and automatically switches to generator power, providing peace of mind for users.

One of the unique aspects of the 09290-4 is its low oil level shutdown feature that protects the engine from damage, prolonging its lifespan. It is also equipped with Generac's G-Force engine, known for its durability and performance. The model is designed for easy maintenance, featuring accessible parts and a user-friendly maintenance schedule.

Both Generac models incorporate advanced safety features, such as circuit breakers and alert systems, ensuring safe operation. In summary, the Generac 00784-2 and the 09290-4 exemplify the brand's commitment to quality and innovation, offering reliable power solutions tailored to meet a variety of needs, whether for outdoor adventures or home backup.