The generator covered by this manual produces dangerous electrical voltages and can cause fatal electrical shock. Avoid contact with bare wires, ter- minals, connections, etc., while the unit is running. Ensure all appropriate covers, guards and barriers are in place before operating the generator. If you must work around an operating unit, stand on an insulated, dry surface to reduce shock hazard.

Do not handle any kind of electrical device while standing in water, while barefoot, or while hands or feet are wet. DANGEROUS ELECTRICAL SHOCK MAY RESULT.

During installation onto the vehicle, have the genera- tor properly grounded (bonded) either by solid mounting to the vehicle frame or chassis, or by means of an approved bonding conductor. DO NOT disconnect the bonding conductor, if so equipped. DO NOT reconnect the bonding conductor to any generator part that might be removed or disassem- bled during routine maintenance. If the grounding conductor must be replaced, use only a flexible con- ductor that is of No. 8 American Wire Gauge (AWG) copper wire minimum.

In case of accident caused by electric shock, imme- diately shut down the source of electrical power. If this is not possible, attempt to free the victim from the live conductor. AVOID DIRECT CONTACT WITH THE VICTIM. Use a nonconducting imple- ment, such as a rope or board, to free the victim from the live conductor. If the victim is uncon- scious, apply first aid and get immediate medical help.

Never wear jewelry when working on this equip- ment. Jewelry can conduct electricity resulting in electric shock, or may get caught in moving com- ponents causing injury.

For fire safety, the generator must be installed and maintained properly. Installation always must comply with applicable codes, standards, laws and regulations. Adhere strictly to local, state and national electrical and building codes. Comply with regulations the Occupational Safety and Health Administration (OSHA) has established. Also, ensure that the generator is installed in accordance with the manufacturer’s instructions and recommendations. Following proper installa- tion, do nothing that might alter a safe installation and render the unit in noncompliance with the aforementioned codes, standards, laws and regu- lations.

Keep a fire extinguisher in the vehicle at all times. Extinguishers rated “ABC” by the National Fire Protection Association are appropriate for use on the recreational vehicle generator electrical system. Keep the extinguisher properly charged and be familiar with its use. If you have any question per- taining to fire extinguishers, consult your local fire department.

EXPLOSION HAZARDS

Do not smoke around the generator. Wipe up any fuel or oil spills immediately. Ensure that no com- bustible materials are left in the generator com- partment, or on or near the generator, as FIRE or EXPLOSION may result. Keep the area surround- ing the generator clean and free from debris.

Gasoline is extremely FLAMMABLE and its vapors are EXPLOSIVE. Do not permit smoking, open flame, sparks or any source of heat in the vicinity while handling gasoline. Comply with all laws gov- erning the storage and handling of gasoline.

Generac® Power Systems, Inc. 3

Image 5
Contents Power SYSTEMS, INC Introduction Authorized Service Dealer LocationTable of Contents General Hazards Electrical Hazards Reference Number Identification Generator IdentificationSafety InstallationGenerator Applicability Generator AC Connection SystemFuel Requirements SpecificationsEngine Generator PP50G/PP70GAutomatic Choke Generator Control PanelOptional Remote START/STOP Panel Starting the Generator Before Starting the EngineProtection Systems Stopping the GeneratorOvervoltage Protection Additional Information1 25-HOUR BREAK-IN Period 2 25-HOUR CHECK-UPChanging the Engine OIL AND/OR OIL Filter Checking the Engine OIL LevelClean AIR Intake Screen Maintaining the Engine AIR CleanerCleaning the Foam Precleaner Checking the Engine Spark PlugBattery Maintenance Cleaning the GeneratorSpark Arrestor Muffler WeeklyRemoval from Service OUT of Service ProcedureDrive Belt Exercising the GeneratorWattage Reference Guide Return to ServicePrimepact 50 and 70 50Hz Recreational Vehicle Generators Part General Hazards Electrical Hazards Equipment Description Purpose and Scope ManualGenerator Engine Operating Speed Standards BookletsPrimePact 50 Generator Location Location and SupportGenerator Support Suspended MountingGenerator Restraint Generator CompartmentsCompartment Construction Compartment SizeSound Insulating Materials AcousticsTypical Noise Abatement Compartment Floor CutoutsCooling AIR Inlet Openings Cooling and Ventilating AIRGenerator Airflow Compensating for Restrictions Testing the InstallationGasoline Fuel System Fuel Tank Flexible Fuel Line Exhaust SystemGenerator Fuel Supply Line Rigid Fuel LinesElectrical Connections Exhaust System SafetyMufflers and Spark Arrestors Type of Exhaust SystemPower Supply Cord Isolating Different Power SourcesGround Fault Circuit Inter Rupters Generator AC Connections18 Transfer Switch Isolation Method Recommended Battery Optional AccessoriesBattery Cables Battery Cable ConnectionsTesting Under Load Post Installation TestsBefore Initial START-UP Initial StartInstallation Checklist Problem Cause Correction Troubleshooting GuideElectrical Data Electrical Data Exploded Views and Parts Lists QTY Description Exploded Views and Parts Lists Lower Bearing Carrier Exploded Views and Parts Lists Bevelled Washer Exploded Views and Parts Lists Cylinder Assembly Exploded Views and Parts Lists Carburetor Assemby PURCHASER’S/OWNER’S Warranty Responsibilities Your Warranty Rights and ObligationsMANUFACTURER’S Emission Control System Warranty Coverage Emission Related Parts Include the Following Emission Control System WarrantyRevised 10/05/01

00784-2, 09290-4 specifications

Generac is a prominent name in the power equipment industry, known for its reliable backup generators and innovative solutions. Among its impressive lineup are models like the Generac 00784-2 and the 09290-4, both designed to provide dependable performance for a variety of applications.

The Generac 00784-2 is a versatile portable inverter generator that stands out for its quiet operation and efficient power output. With a peak wattage of 3,300 watts and a running wattage of 2,600 watts, this generator is perfect for camping trips, tailgating, or as a backup power source during emergencies. One of the defining features of the 00784-2 is its TruePower Technology, which produces clean and stable power suitable for sensitive electronics such as laptops and smartphones. Additionally, its economy mode helps optimize fuel efficiency, allowing users to extend runtime while minimizing noise levels.

Weighing only 46 pounds, the 00784-2 is designed for mobility. Its compact design and integrated handle make transport and storage a breeze. The generator also features a built-in fuel gauge, enabling users to easily monitor fuel levels, and its easily accessible control panel allows for user-friendly operation.

On the other hand, the Generac 09290-4 is a powerful stationary generator aimed at providing robust backup power for homes and small businesses. With a 10,000-watt output, the 09290-4 can seamlessly power essential appliances during power outages, ensuring comfort and safety. This model features an automatic transfer switch, which detects power outages and automatically switches to generator power, providing peace of mind for users.

One of the unique aspects of the 09290-4 is its low oil level shutdown feature that protects the engine from damage, prolonging its lifespan. It is also equipped with Generac's G-Force engine, known for its durability and performance. The model is designed for easy maintenance, featuring accessible parts and a user-friendly maintenance schedule.

Both Generac models incorporate advanced safety features, such as circuit breakers and alert systems, ensuring safe operation. In summary, the Generac 00784-2 and the 09290-4 exemplify the brand's commitment to quality and innovation, offering reliable power solutions tailored to meet a variety of needs, whether for outdoor adventures or home backup.