Generac ASPAS1CCL015 Panel Back & Bottom, Screw Hhtt M5-0.8 X 12 BP, Panel LH Side, Holder Fuse

Page 35

Section 9 - Exploded Views and Parts

Carrier Liquid-cooled 15 kW Generators

Control Panel — Drawing No. 0F5240

ITEM

PART NO.

QTY.

DESCRIPTION

ITEM

PART NO.

QTY.

DESCRIPTION

1

0D9322

1

PANEL BACK & BOTTOM

30

0C2267

14

SCREW HHTT M5-0.8 X 12 BP

2

0D9332

1

PANEL LH SIDE

31

023897

15

WASHER FLAT #10 ZINC

3

0F5246A

1

PANEL FRONT W/SILKSCREEN

32

0C2454

4

SCREW TH-FRM M6-1X16 N WA Z/JS

4

0D9330

1

PANEL RH SIDE C-PANEL SML BRK

33

054199

1

DECAL HIGH VOLTAGE

5

0E3783

1

DECAL WARNING REMOVE FUSE

34

081988

1

DECAL EXERCISE INFO

6

064009

1

LIGHT 12VDC .02A LED RED PILOT

35

0E2514

1

STRAIGHT WIRE CONNECTOR 1 1/2"

7

032300

1

HOLDER FUSE

36

0A1354A

1

REGULATOR - DC ALT

8

022676

1

FUSE 15A X AGC15

37

074908

4

SCREW HHTT M5-0.8 X 10 BP

9

0E4494

1

SWITCH ROC DPDT ON-OFF-ON

38

020911

4

SCREW PPHM M5-0.8 X 30 ZINC

10

082573

1

SWITCH ROCKER DPST 125V SPD

39

051713

5

WASHER FLAT M5

11

083048

1

ASSEMBLY REGULATOR POTTED

40

049226

5

WASHER LOCK M5

12

083264

1

TFMR ASM CMA 240/12V

41

051716

5

NUT HEX M5-0.8 G8 YEL CHR

13

076009A

1

PP LOGIC ASM 50/60HZ

42

036261

4

RIVET POP .125 X .129-.133/#30

14

0E0331A

1

HARN CONTROL PANEL 1.5L MITSU

43

0D9334

1

PANEL, TOP

 

 

 

(NOT SHOWN)

44

061979

1

BUS BAR

15

056739

1

RELAY SOLENOID 12VDC PNL MNT

45

022237

1

WASHER LOCK 3/8

16

049350

1

CIRCT BRK 4 X 1 ETA 46-500-P

46

022241

1

NUT HEX 3/8-16 STEEL

17

047822

1

BLOCK TERM 20A 7 X 6 X 1100V

47

057073

1

JUNCTION BLOCK 3/8-16

18

048766

1

BLOCK TERM 20A 2 X 6 X 1100V

48

055440

1

SCREW HHC M5-0.8 X 25 G8.8

19

057335

1

BLOCK TERM 20A 20 X 6 X 1100V

49

0D8671

1

HINGE CONTINUOUS 1.5L CNTL PNL

20

098647

1

ASSY L.C. ELECT GOV

50

0912970080

1

WIRE ASSEMBLY

21

0E1454

1

DECAL CUST. CONNT. PRE-PACK1.5L

51

049813

1

NUT HEX M6 X 1.0 G8 YEL CHR

22

0E1459

1

DECAL TERMINAL STRIP PRE-PACK

52

033121

1

SCREW HHC #10-32 X 1/2

23

072566

4

NUT SPACER.250 PCB

53

026850

1

WASHER SHAKEPROOF EXT 1/4

24

080882

8

SCREW PPH TAPPING #6 X 5/8 SS

 

 

 

STL

25

0A8955

2

SCREW PHM M6-1.0 X 20MM

54

022158

1

NUT HEX #10-32 STEEL

26

022097

3

WASHER LOCK M6-1/4

55

022152

1

WASHER LOCK #10

27

022473

2

WASHER FLAT 1/4-M6 ZINC

56

0A3968

1

CAPACITOR FILTER ASY

28

0C2212

10

SCREW PHTT M4-0.7 X 16 ZYC

57

0C2323

2

SCREW PHTT #6-32 X 5/8 ZYC

29

023762

2

WASHER SHAKEPROOF EXT #10

 

 

 

 

 

 

 

STL

 

 

 

 

Carrier 33

Image 35
Contents Liquid-cooled, Prepackaged Standby Generators Your Carrier Dealer is ‹ Operation and Maintenance‹ HOW to Obtain Service IntroductionIntroduction IFC Safety Rules General Hazards ‹ Standards Index Fire HazardsGenerator AC Connection Systems Transfer SwitchGenerator Automatic System OperationGenerator Fuel System ‹ 1.7.1 LOW OIL Pressure Switch‹ 1.7.2 High Coolant Temperature Switch ‹ 1.7.3 LOW Coolant Level SwitchLifting the Generator SpecificationsUnpacking Fuel Consumption Reconfiguring the Fuel SystemTorque Specifications ‹ 1.10.2 Engine Specifications‹ 2.1.1 Nfpa Standards Before InstallationEngine OIL Recommendations Coolant Recommendations‹ 2.1.2 Other Published Standards Generator Mounting SupportBasic Standby Electric System Generator LocationGenerator AC Neutral Connections Transfer Switch Signal ConnectionsEmergency Circuit Isolation Method Total Circuit Isolation Method‹ 2.11.1 Prior to Initial START-UP Battery InstallationPreparation Before START-UP ‹ 2.10.1 Vented BatteriesControl Console Components Weekly Exercise Cycle ‹ 3.1.2 Fault Indicator Lamp‹ 3.1.5 SET Exercise Time Switch Manual Transfer START-UP Automatic OperationChecking Fluid Levels Overload Protection for Engine DC Electrical SystemCooling System ‹ 4.5.1 Check Engine OIL Level ‹ 4.4.2 Battery Fluid ‹ 4.5.7 Inspect Exhaust System‹ 4.5.2 Check Battery ‹ 4.4.3 Engine Coolant‹ 4.5.12 Spark Plugs Miscellaneous Maintenance‹ 4.5.11 Changing the Engine AIR Cleaner ‹ 4.6.1 Cleaning the Generator‹ 4.6.4 Battery Replacement ‹ 4.6.2 Battery‹ 4.6.3 Battery Maintenance Service Maintenance Interval Information Scheduled MaintenanceLevel Maintenance Level Problem Cause Correction Troubleshooting PointsCarrier Liquid-cooled 15 kW Generators Installation Diagram Electrical Data Customer Connection DC-VR To Control Panel Terminal Strip ASM Motor Stepper Housing Governor ConnectorConnector Interface Assembly Cover Connector HousingWasher Flat 5/16 Zinc Base Mounting 1.5L Stnrd & AcstcWasher Shakeproof EXT 5/16 STL Dampener VibrationPanel for Access Roof ACSTC&STND Cmprtmnt 1.5L Assembly BASE-DOOR Ground WireGRD Wire Assy 99HSB Assembly Cover AccessATO Screw Hhtt M5-0.8 X 12 BP Switch ROC Dpdt ON-OFF-ONWire Assembly Panel Back & BottomWaterpump Hardware ENGINE-1.5L Switch OIL PressureARM Adjust Alternator Ground Wire Starter14 21 Guard FAN 1.5L Modine Tank Coolant RecoveryRadiator 1.5L Venturi 1.5L ModineVapor Flange Fuel Inlet Cover AIR CleanerGasket AIR Cleaner Adapter Weldment Mounting BaseOTH Blowgousin re Assy Rotor 20KW Housing BlowerAssy Rotor 10KW Assy Rotor 15KWBattery Post Cover RED+ ASSY,WIRE#16 REDBOOT, Battery Cable BRACKET, Battery Hold DownPIPE,EXHAUST 1.5L STNDRD&ACSTC Manifold Exhaust 1.5LNipple TOE 1.5NPTX5.5 BLK Iron Saddle 2 InchPURCHASER’S/OWNER’S Warranty Responsibilities Your Warranty Rights and ObligationsMANUFACTURER’S Emission Control System Warranty Coverage Emission Related Parts Include the Following Emission Control System WarrantyWarranty Schedule

ASPAS1CCL015 specifications

The Generac ASPAS1CCL015 is a cutting-edge automatic standby generator that provides reliable backup power in the event of an electrical outage. Designed with innovative technology and robust features, it ensures that homes and businesses can maintain essential operations without interruptions, enhancing peace of mind and safety during unforeseen power disruptions.

One of the standout features of the Generac ASPAS1CCL015 is its powerful engine, designed to produce up to 15 kilowatts of electricity. This makes it suitable for a wide range of applications, from residential homes to small commercial establishments. The generator operates on propane or natural gas, providing flexibility in fuel options based on user preferences or availability in their region.

Incorporating advanced technologies, the ASPAS1CCL015 is equipped with an automatic transfer switch (ATS). This feature allows the generator to automatically detect power outages and start up within seconds, ensuring that homes remain powered without a manual start. The ATS also reassesses whether the utility power has restored, allowing for a smooth transition back to grid power when available.

The unit is designed to be both quiet and efficient, featuring a low-emission engine that meets stringent environmental standards. This is an increasingly important consideration for many users concerned about eco-friendliness. Its noise-reduction technology ensures that operation is not disruptive, allowing users to run the generator during night hours without disturbing the peace.

In terms of user-friendly features, the Generac ASPAS1CCL015 is equipped with an intuitive digital control panel. Users can easily monitor the generator's status, run diagnostic checks, and access maintenance reminders. This enhances the overall user experience and promotes proactive care of the equipment.

Durability is another hallmark of the ASPAS1CCL015. Constructed with corrosion-resistant materials, the generator can withstand various weather conditions, making it a reliable option for outdoor settings. Its compact design allows for easy installation, whether in a garage, basement, or an external concrete pad.

Overall, the Generac ASPAS1CCL015 combines reliability, advanced technology, and user-friendly features to deliver a dependable electricity solution. Its capability to seamlessly transition between power sources, coupled with the sustainable operation, positions it as an excellent choice for those looking to safeguard their homes or businesses against power outages.