Generac 97193 manual Cold Weather Operation, Stopping the Engine

Page 7

Generac Portable Products SVP5000 Generator

Stopping the Engine

Unplug all electrical loads from generator panel receptacles. Never start or stop engine with electrical devices plugged in and turned on.

For a more permanent shelter, build a structure that will enclose three sides and the top of the generator:

Make sure entire muffler-side of generator is exposed. A typical shelter is shown in Figure 6.

Let engine run at no-load for several minutes to stabilize the internal temperatures of engine and generator.

Move engine control switch to the “Off” position.

Close the fuel shut–off valve.

COLD WEATHER

OPERATION

Under certain weather conditions (temperatures below 40°F [4°C] and a high dew point), your Generac generator may experience icing of the carburetor and/or the crankcase breather system.

In an emergency, use the original shipping box as a temporary shelter:

Cut off all flaps.

Cut out one of the long sides of the box to expose exhaust side of unit. Ensure a minimum of two feet clearance between open side of box and nearest object.

Cut appropriate slots to access receptacles of unit. You may also need to cut a clearance slot for the handle.

Start unit, then place box over it.

IMPORTANT: Remove shelter when temperature is above 40°F [4°C].

Figure 6 — Typical Cold Weather Temporary Shelter

Wind

Ensure a minimum of two feet clearance between open side of box and nearest object.

Face exposed end away from wind and elements.

Enclosure should hold enough heat created by the generator to prevent icing problems.

CAUTION! Never run unit indoors; Do Not enclose generator any more than shown. Remove shelter when temperatures are above 40°F [4°C].

7

Image 7
Contents SVP5000 Equipment Description Safety RulesNever operate the generator Grounding GeneratorKnow Your Generator To fill your engine with oil Before Starting the EngineAdd Oil Add GasolineStarting the Engine Connecting Electrical LoadsStopping the Engine Cold Weather OperationVolt AC, 30 Amp Locking Receptacle ReceptaclesVolt AC, 20 Amp Duplex Receptacles 120/240 Volt AC, 20 Amp Locking ReceptacleProfessional/Contractor Uses DON’T Overload the GeneratorRecreational/Home Uses WattsGeneral Maintenance Recommendations SpecificationsStorage Instructions Troubleshooting Electrical Schematic Wiring Diagram Exploded View Generator Accessories Not Illustrated Parts List GeneratorQty Description For Portable Generators Limited Warranty