Do Not use worn, bare, frayed or otherwise damaged electrical cord sets with the generator. Using a defective cord set may result in electrical shock or damage to equipment and/or property.

Operate unit only on level surfaces and where it will not be exposed to excessive moisture, dirt, dust or corrosive vapors.

Gasoline is highly FLAMMABLE and its vapors are EXPLOSIVE. Do Not permit smoking, open flames, sparks or heat in the vicinity while handling gasoline. Avoid spilling gasoline on a hot engine. Comply with all laws regulating storage and handling of gasoline.

Do Not overfill the fuel tank. Always allow room for fuel expansion. If tank is overfilled, fuel can overflow onto a hot engine and cause FIRE or EXPLOSION.

Never store a generator with fuel in the tank where gasoline vapors might reach an open flame, spark or pilot light (as on a furnace, water heater, clothes dryer). FIRE or an EXPLOSION may result.

Generator exhaust gases contain DEADLY carbon monoxide gas. This dangerous gas, if breathed in sufficient concentrations, can cause unconsciousness or even death. Operate this equipment only in the open air where adequate ventilation is available.

The unit requires an adequate flow of cooling air for its continued proper operation. Never operate the unit inside any room or enclosure where the free flow of cooling air into and out of the unit might be obstructed. Allow at least 2 feet of clearance on all sides of generator or you could damage the unit. Read “Cold Weather Operation” on page 7.

Never start or stop the engine-generator with electrical loads connected to receptacles with the connected devices turned ON. Start the engine and let it stabilize before connecting any electrical loads. Disconnect all electrical loads before shutting down the generator.

Do Not insert any object through cooling slots of the engine-generator. You could damage the unit or injure yourself.

Never operate the generator:

in rain; in any enclosed compartment; when connected electrical devices overheat; if electrical output is lost; if engine or generator sparks; if flame or smoke is observed while unit is running; if unit vibrates excessively.

GROUNDING THE

GENERATOR

The National Electrical Code requires that the frame and external electrically conductive parts of this generator be properly connected to an approved earth ground. Local electrical codes may also require proper grounding of the unit. For that purpose, a GROUNDING WING NUT is provided on the generator end (Figure 1).

Figure 1 — Grounding Wing Nut

Grounding Wing Nut

Generally, connecting a No. 12 AWG (American Wire Gauge) stranded copper wire to the grounding wing nut and to an earth-driven copper or brass grounding rod (electrode) provides adequate protection against electrical shock. Be careful to keep the grounding wire attached after connecting the stranded copper wire. However, local codes may vary widely. Consult with a local electrician for grounding requirements in your area.

Properly grounding the generator helps prevent electrical shock if a ground fault condition exists in the generator or in connected electrical devices. Proper grounding also helps dissipate static electricity, which often builds up in ungrounded devices.

3

Image 3
Contents SVP5000 Equipment Description Safety RulesNever operate the generator Grounding GeneratorKnow Your Generator To fill your engine with oil Before Starting the EngineAdd Oil Add GasolineStarting the Engine Connecting Electrical LoadsStopping the Engine Cold Weather OperationVolt AC, 30 Amp Locking Receptacle ReceptaclesVolt AC, 20 Amp Duplex Receptacles 120/240 Volt AC, 20 Amp Locking ReceptacleProfessional/Contractor Uses DON’T Overload the GeneratorRecreational/Home Uses WattsSpecifications General Maintenance RecommendationsStorage Instructions Troubleshooting Electrical Schematic Wiring Diagram Exploded View Generator Parts List Generator Accessories Not IllustratedQty Description For Portable Generators Limited Warranty