Armstrong World Industries ACUM210, ACUM84, ACUM140, ACUM185, ACUM65, ACUM110 Introduction, General

Page 5

Page 5

1. INTRODUCTION

This manual provides general safety information for installing, operating and maintenance of Armstrong Power equipments. The purchaser should comply with the instructions and information in this manual, and is strongly ad- vised that all personnel to be associated with the equipment supplied should be made familiar with the information contained herein.

It is essential that the personnel engaged in the installation, commissioning and maintenance of this equipment are both competent and experienced in these fields, and that they comply with the relevant statutory requirements and regulations, including he provisions of the Health and Safety act 1974, and any such modifications and amendments which may subsequently become a legal requirement.

The equipment supplied by Armstrong Power should be installed by, or under the supervision of, competent person- nel in accordance with good engineering practice, established codes of practice, those statutory requirements appli- cable to the installation site, the IEE regulations as applicable and, where the appropriate, in accordance with any instructions specifically advised by the company.

You are requested, in accordance with the needs of safe operation and the provisions of the act, to take such steps as are necessary to ensure that the appropriate information on the proper use and handling of our equipment is made available by yourself to all those concerned. Similarly, this information must be available to anyone who may purchase, or otherwise acquire from your self, such products for use in their own premises.

2. GENERAL

The generating set is designed to be safe when used in the correct manner. The following safety precautions, if fol- lowed will minimize the possibility of accidents. Before performing any procedure or operating technique, it is up to the user to ensure that it’s safe. The generating set should only be operated by personnel who are authorized and trained.

Warning:

Read and understand all safety precautions, and warnings before operating the generating set.

Failure to follow the instructions, procedures and safety precautions in this manual may increase the possibility of accidents and injuries.

Never start the generating set unless it is safe to do so.

Do not attempt to operate the generating set with a know unsafe condition.

If the generating set is unsafe, fit danger notices and disconnect the battery negative (-) lead so that it cannot be started until the condition is corrected.

Disconnect the battery negative (-)lead prior to attempting any repairs or cleaning inside the enclosure, if equipped.

Appropriate firefighting equipment is to hand.

The metal work on every part of the generating set must be connected by means of an earth continuity conduc- tor to an effective earth point.

Care must be taken to avoid spillage from the batteries.

No loose items or combustible material should be left on or against any part of the generator.

Do not risk injury by coming into contact with moving parts of the plant, or by allowing anything to be draw in by the cooling fan or intake system.

Install and operate this generating set only in full compliance with relevant National, local or federal codes, standards or other requirements.

AR-EXP-CUMMINS-07-00

OWNERS MANUAL

Image 5
Contents Cummins Series AR-EXP-CUMMINS-07-00 Warranty Certificate AR-EXP-CUMMINS-07-00 General IntroductionFire and Explosion INSTALLATION, Handling and TowingChemical MechanicalElectrical NoiseWhat to do First AID for Electric ShockCall BlowSpecial Considerations for Battery Generating SET Installation Mounting LocationGROUND/FLOOR Loading Ventilation Outdoor Installations AIR Cooled Units Electrical System Connecting the GeneratorGeneral Electrical System General Rules for Exhaust SystemFuel System Installation Checklist Battery InstallationLocation Electrical ConnectionsAR-EXP-CUMMINS-07-00 Generating SET Operation Maintenance Electrical Checks PRE-OPERATION CheckGenerator Tests Under Load ShockChecking Automatic Operation GeneratorInstallation and Application ACUM84 ACUM110 ACUM140 ACUM185 ACUM210 Shutdowns Automatic Mode of OperationTerminal Description Settings Fixed SettingsInstruments Reading Maintenance ScheduleEngine Checks During Operation Radiator Cooling water CoolantEvery 250 Hours or 3 Months Maintenance Check 1 Daily or Refueling Maintenance Check4Every 500 Hours or 6 Months Maintenance Every 2000 Hours or 2 Years Maintenance CheckAPI CG-4/SH, API CD, API Acea E-1 CUMMINS/FLEETGUARD Filter SpecificationsNot OK OBSOLETE. do not Maintennce of Bearings AlternatorInspection and Maintenace Intervals USE of Potentiometers Voltag Regulator

ACUM210, ACUM110, ACUM65, ACUM185, ACUM140 specifications

Armstrong World Industries has established itself as a leader in the design and manufacture of innovative ceiling and wall solutions. Among their notable acoustic ceiling offerings are the ACUM84, ACUM210, ACUM65, ACUM140, and ACUM185 tiles. Each of these products is engineered with distinct features and technologies aimed at enhancing acoustic performance, durability, and aesthetics in various commercial spaces.

The ACUM84 is designed for spaces that prioritize sound absorption and overall acoustic quality. It utilizes advanced sound-dampening technology, making it suitable for environments such as offices, schools, and healthcare facilities. This tile achieves a high Noise Reduction Coefficient (NRC), effectively minimizing sound reverberation, which is essential for maintaining concentration in busy settings.

Similarly, the ACUM210 offers enhanced acoustic properties but with a focus on durability. This tile is constructed with a robust material that is resistant to impact and moisture, making it an excellent choice for high-traffic areas. The fabric-like texture not only adds aesthetic value but also improves its sound-absorbing capabilities, contributing to a quieter environment.

For those seeking a versatile solution, the ACUM65 is an ideal option. This tile is lightweight yet durable, making installation straightforward. Its ecological design ensures minimal environmental impact while providing superior acoustic performance. The ACUM65 is particularly well-suited for retail spaces, where customer experience can be significantly enhanced by better sound control.

ACUM140 is engineered for flexibility and design versatility. With a range of finishes and colors, it allows architects and designers to incorporate acoustic solutions that harmonize with the overall aesthetic of the space. Its high NRC rating ensures a calm auditory environment, making it an excellent fit for restaurants and auditoriums.

Lastly, the ACUM185 combines aesthetics with functionality, offering a sleek design while maintaining outstanding sound absorption capabilities. It meets the demands of contemporary styling without compromising performance. This tile is particularly favored in corporate environments where aesthetics play a crucial role in branding and employee satisfaction.

In conclusion, Armstrong's ACUM product line, including ACUM84, ACUM210, ACUM65, ACUM140, and ACUM185, showcases technologies and characteristics that cater to a variety of applications. With a strong focus on acoustic management, durability, and design versatility, Armstrong continues to provide innovative solutions tailored to the needs of modern commercial spaces.