Cobra Electronics PI2000 manual Connection

Page 6

Connection

Connection

 

 

Connection

continued

CAUTION: Loosely tightened connectors can cause exces- sive voltage drops and may result in overheated wires and melted insulation.

CAUTION: A reverse polarity connection (positive to nega- tive) will blow the fuse in the inverter and may permanently damage the unit.

CAUTION: Remove any jewel- ry (watch, ring etc.). Be careful not to short circuit the battery with any metallic object (wrench, etc.).

NOTE: If only one power source is used, connect both cables from the negative ter- minal of the inverter to the negative terminal of the power source. Then connect both cables from the positive termi- nals of the inverter to the posi- tive terminal of the power source.

2.Connect both sets of cables to the power input terminals on right side panel of the inverter. The red terminals are positive (+) and the black terminals are negative (-). Insert the bare ends of the cables into the terminals and tighten the screws to clamp the wires safely.

3.Connect each cable from the negative (black) terminal of inverter to the negative terminal of the power source. Make a secure connection.

All power connections to your Cobra inverter must be positive to positive and negative to negative.

4.Connect the cables from the positive (red) ter- minals of the inverter to the positive terminal of the power source. Make a secure connection.

5.If a DC power supply is being used as the power source, switch it On. Turn the ON/OFF switch on the inverter to the On position. Check the meters on the left side panel. The voltage should indicate between 11 and 14 volts, depending on the voltage of the power source.

6.Turn the inverter’s ON/OFF switch to the Off position. The indicator lights may blink and the internal alarm may sound momentarily.

This is normal. Plug the test load into the AC receptacle on the left side panel of the invert- er. Leave the test load switched Off.

7.Switch the inverter’s ON/OFF switch to the On position and turn the test load On. The inverter should supply power to the load.

If it does not, please consult the troubleshoot- ing section in this manual.

Connection

continued

WARNING: You may observe a spark when making the con- nection because current can flow to charge the capacitors in the inverter. Do not make

this connection in the pres- ence of flammable fumes.

Explosion or fire may result.

6

7

 

 

Image 6
Contents How Your HG PI2000 Power Inverter Works How Your Cobra Power Inverter WorksControls and Indicators Customer SupportHow to Use Your HG PI2000 Power Inverter ContentsIntroduction Cobra 2000W Output WaveformQuick Quick Checkout Testing/ConnectionTesting Connection CheckoutConnection Installation Installation Mounting/CablesInstallation MountingCables Ground Wiring Ground WiringGround Wiring DC Wiring DC WiringDC Wiring OperationControls and Indicators Operating Limits Controls and Indicators Operating LimitsOperating Limits Input Voltage Solution Troubleshooting Guide MaintenanceMaintenance MaintenancePower Consumption Specifications SpecificationsLimited Three Year Warranty Cobra Electronics CorporationIf You Think You Need Service 773

PI2000 specifications

Cobra Electronics has long been recognized for its innovative approach to communication and navigation solutions, and the PI2000 is a testament to this commitment. The Cobra PI2000 is a high-performance personal locator beacon designed for outdoor enthusiasts and adventurers who seek reliability and peace of mind during their excursions.

One of the standout features of the PI2000 is its advanced GPS technology. The device integrates satellite-based positioning, which allows users to pinpoint their exact location with remarkable accuracy. In emergency situations, this feature is invaluable, as it can significantly shorten response times for rescue operations. The PI2000 transmits critical GPS coordinates to search and rescue teams, ensuring that help can be dispatched without delay.

In addition to its GPS capabilities, the PI2000 is equipped with a powerful 406 MHz beacon, which is internationally recognized as the standard frequency for emergency beacons. This frequency allows the device to send distress signals to the nearest search and rescue authorities. Its 121.5 MHz homing signal aids rescuers in locating the device once the distress signal is received. This dual-frequency capability enhances the likelihood of a quick and efficient rescue in challenging terrain.

The build quality of the Cobra PI2000 is another key characteristic. Engineered to withstand harsh environmental conditions, it is both waterproof and rugged, making it suitable for various outdoor activities, from hiking and camping to boating and skiing. The device's ergonomic design ensures that it can be easily operated, even while wearing gloves, which is essential during emergencies.

Another significant aspect of the PI2000 is its battery life. It utilizes a robust lithium battery, designed to provide extended usage times, which is crucial during prolonged outdoor adventures where recharging may not be feasible. The device also features a low-battery indicator, alerting users when it's time to replace or recharge the battery, further enhancing safety.

User-friendly features such as a simple activation mechanism make the Cobra PI2000 accessible for individuals of all experience levels. A single push of a button can initiate a distress signal, which can especially be vital in high-stress situations.

Overall, the Cobra PI2000 represents a critical piece of equipment for anyone who spends time in remote or risky environments. With its combination of advanced GPS technology, reliable beacon transmission, rugged design, and user-centered features, it stands out as a must-have safety tool for adventurers seeking to explore the great outdoors.