Cobra Electronics PI2000 manual Installation Mounting/Cables

Page 7

Installation

Mounting/Cables

 

 

Installation

CAUTION: To avoid fire, do not cover or obstruct ventilation openings. Do not install invert- er in a zero-clearance com- partment. Overheating may result.

WARNING: This unit contains components which can pro- duce arcs or sparks. To prevent fire or explosion, do not install in compartments containing a battery or flammable materi- als, or in a location which requires ignition protected equipment.

Installation

The inverter must be installed in an area that meets all of the following requirements:

A.Dry- Do not place in an area where water can drip or splash on the inverter.

B.Cool- Ambient air temperature should be between 30° F and 105° F (0° C and 40° C). The cooler the better.

C.Ventilate- Allow at least 1 inch (3cm) of clear- ance around the inverter for proper airflow. Make sure that ventilation openings on the ends of the unit are not obstructed.

D.Safe- Do not install the inverter in the same compartment as a battery or in any compart- ment that contains flammable liquids such as gasoline.

E.Close to battery- Install unit as close to bat- tery as possible (without being in the same compartment) to minimize the length of cable required to connect the inverter to the battery. It is better and cheaper to run longer AC wires than longer DC wires (cables).

Mounting

Mount the inverter on a flat surface placing the mounting bracket on the bottom. Mounting hardware should be corrosion resistant and at least #10 or larger. The inverter can be mounted horizontally or vertically.

Cables (included)

Power wire and wiring is very important to the performance of the inverter. Because the inverter has a low voltage, high current input, low resis- tance wiring is essential between the battery and inverter. This is so it can deliver the maximum amount of energy to the load.

Use only copper wire. Aluminum wire has about 1/3 more resistance than copper wire of the same size plus it is difficult to make good, low- resistance connections to aluminum wire.

We recommend two #4 copper cables (90° C insulation rating) as the minimum size for con- nections between the battery and inverter.

Keep the cable length as short as possible, no more than 4 ft. (1.5 meters). This will keep the voltage drop to a minimum.

Mounting

CAUTION: The inverter must only be connected to batteries with a nominal output voltage of 12 volts. It will not work with a 6 volt battery, and will be damaged if it is connected to a 16 volt battery.

WARNING: If you are making a permanent AC connection to the inverter, make sure that the AC wiring steps are performed before any DC wiring is done. (DC hook-up energizes internal components, regardless of the position of the ON/OFF switch). Working on AC connections in such a circumstance may result in an electric shock.

WARNING: 115 Volt AC power is potentially lethal. Do not work on AC wiring when it is connect- ed to the inverter (even if it is switched off) unless the DC power source is physically dis- connected form the inverter. Also, do not work on AC wiring if it is connected to another AC power source such as a genera- tor or the utility line.

8

9

 

 

Image 7
Contents How Your Cobra Power Inverter Works How Your HG PI2000 Power Inverter WorksCustomer Support Controls and IndicatorsContents How to Use Your HG PI2000 Power InverterCobra 2000W Output Waveform IntroductionCheckout Quick Checkout Testing/ConnectionTesting Connection QuickConnection Mounting Installation Mounting/CablesInstallation InstallationGround Wiring Cables Ground WiringGround Wiring Operation DC WiringDC Wiring DC WiringControls and Indicators Operating Limits Controls and Indicators Operating LimitsOperating Limits Input Voltage Maintenance Troubleshooting Guide MaintenanceMaintenance SolutionSpecifications Power Consumption SpecificationsCobra Electronics Corporation Limited Three Year Warranty773 If You Think You Need Service

PI2000 specifications

Cobra Electronics has long been recognized for its innovative approach to communication and navigation solutions, and the PI2000 is a testament to this commitment. The Cobra PI2000 is a high-performance personal locator beacon designed for outdoor enthusiasts and adventurers who seek reliability and peace of mind during their excursions.

One of the standout features of the PI2000 is its advanced GPS technology. The device integrates satellite-based positioning, which allows users to pinpoint their exact location with remarkable accuracy. In emergency situations, this feature is invaluable, as it can significantly shorten response times for rescue operations. The PI2000 transmits critical GPS coordinates to search and rescue teams, ensuring that help can be dispatched without delay.

In addition to its GPS capabilities, the PI2000 is equipped with a powerful 406 MHz beacon, which is internationally recognized as the standard frequency for emergency beacons. This frequency allows the device to send distress signals to the nearest search and rescue authorities. Its 121.5 MHz homing signal aids rescuers in locating the device once the distress signal is received. This dual-frequency capability enhances the likelihood of a quick and efficient rescue in challenging terrain.

The build quality of the Cobra PI2000 is another key characteristic. Engineered to withstand harsh environmental conditions, it is both waterproof and rugged, making it suitable for various outdoor activities, from hiking and camping to boating and skiing. The device's ergonomic design ensures that it can be easily operated, even while wearing gloves, which is essential during emergencies.

Another significant aspect of the PI2000 is its battery life. It utilizes a robust lithium battery, designed to provide extended usage times, which is crucial during prolonged outdoor adventures where recharging may not be feasible. The device also features a low-battery indicator, alerting users when it's time to replace or recharge the battery, further enhancing safety.

User-friendly features such as a simple activation mechanism make the Cobra PI2000 accessible for individuals of all experience levels. A single push of a button can initiate a distress signal, which can especially be vital in high-stress situations.

Overall, the Cobra PI2000 represents a critical piece of equipment for anyone who spends time in remote or risky environments. With its combination of advanced GPS technology, reliable beacon transmission, rugged design, and user-centered features, it stands out as a must-have safety tool for adventurers seeking to explore the great outdoors.