Connect electrical devices to this generator according to the following procedure:

1.Allow the engine to run for several minutes after it has been started.

2.Confirm that the electrical device is switched off prior to plugging it into this generator.

Connect only electrical devices that are in good working order. Faulty devices or power cords present the risk of electrical shock. Immediately turn off and disconnect any device that commences to operate abnormally, sluggish or abruptly stops. Determine if the problem was the device or the rated load capacity of this generator has been exceeded.

NOTE: Plug appliances into the correct outlet. Connect standard 120 Volt, single phase, 60 Hz loads to the 120 Volt outlet. See Figure 8 for an illustration of these outlets.

Even though this Model GEN2000LP Portable LP Generator has an overall rated wattage of 2000, do not attempt to draw more than 1350 Watts (20 A) from any ONE of the 120 Volt outlets. Draws higher than 1350 Watts (20 A) will damage this generator and void the warranty.

3.Make sure AC Reset button is pressed in.

4.Turn on the connected electrical devices beginning with the device with the highest rated wattage requirement and then each additional device with the next lower rated wattage requirement.

Do not connect 50Hz or 3-phase loads to this generator.

Figure 8 - Outlets Available on this Generator.

SOME NOTES ABOUT POWER CORDS

Long or thin cords can require more wattage from a generator to power an electrical device. Figure 9 shows the recommended cords according to the power requirement of the electrical device. When using cords that exceed these specifications, allow for the electrical device to have a slightly higher rated wattage requirement.

GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Manual

17

Image 17
Contents GEN2000LP This Engine Meets U.S. EPA Emission Standards Under 40 CFR FeaturesTable of Contents Recognize Safety SYMBOLS, Words and Labels Legal Requirements Important Safety InstructionsPage Page Page Package Contents Generator Components Page Preparing the Generator for USE Using this Generator for the First-TimePre-Operation Check List Connect Propane Gas Supply SourceSubsequent Use of this Generator Ground the GeneratorStep Starting the GeneratorAC Usage Using the GeneratorSome Notes about Power Cords DC Usage Stopping the GeneratorRecommended Maintenance Schedule MAINTENANCE/CARECleaning the Generator Checking the Oil LevelChecking the Oil Changing/Adding OilSpark Plug Maintenance Air Filter MaintenanceSTORAGE/TRANSPORT Procedures Troubleshooting AC Output SpecificationsParts Diagram Parts Diagram