Figure 11 - Checking the Oil

Changing/Adding Oil

The oil level in this generator should be checked before each use. (See Figure 10.) When the oil level is low, add oil until the level is sufficient to operate this generator.

The oil capacity for this Model GEN2000LP 2000 Surge Watts / 1350 Running Watts Portable LP Generator engine is 14 fluid oz.

To drain the oil from this generator:

The oil should be changed after the first 20 hours of operation. The oil should then be changed every 6months, or for every 100 hours of use time, or when it has become contaminated with water and/or dirt.

1.Place a bucket underneath this generator to catch oil as it drains.

2.Using a 10 mm hex wrench, unscrew the oil drain plug located on the crankcase underneath the oil filler/dipstick cap as illustrated in Figure 12.

3.Allow all the oil to drain from this generator.

4.Replace the oil drain plug and tighten with a 10 mm hex wrench.

NOTE: Never dispose of used motor oil in the trash, down a drain or on the ground. Put oil in a sealed container and contact your local recycling center or auto garage to arrange oil disposal.

To add oil to the engine crankcase:

1.Confirm that this generator is on a level surface.

2.Unscrew the oil filler/dipstick cap from the engine as illustrated in Figure 11 above.

3.Using a funnel, add high detergent motor oil to fill the engine crankcase to the correct quantity. SAE10W-30 oil is recommended for general use. When the engine crankcase is full, the oil level should reach the lower lip of the oil filling opening as shown in Figure 13.

Model GEN2000LP Oil Capacity

14 oz

Model GEN2000LP Oil Type Recommended

High Detergent Motor Oil, SAE10W-30

Figure 12 - Draining Oil

Figure 13 - Adding Oil

GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Manual

20

Image 20
Contents GEN2000LP Features This Engine Meets U.S. EPA Emission Standards Under 40 CFRTable of Contents Recognize Safety SYMBOLS, Words and Labels Important Safety Instructions Legal RequirementsPage Page Page Package Contents Generator Components Page Using this Generator for the First-Time Preparing the Generator for USEConnect Propane Gas Supply Source Pre-Operation Check ListGround the Generator Subsequent Use of this GeneratorStarting the Generator StepUsing the Generator AC UsageSome Notes about Power Cords Stopping the Generator DC UsageMAINTENANCE/CARE Recommended Maintenance ScheduleCleaning the Generator Checking the Oil LevelChanging/Adding Oil Checking the OilAir Filter Maintenance Spark Plug MaintenanceSTORAGE/TRANSPORT Procedures Troubleshooting Specifications AC OutputParts Diagram Parts Diagram