Buffalo Tools GEN3250 instruction manual Starting the Generator

Page 13

STARTING THE GENERATOR

STOP!

Before starting this generator, confirm that all the steps in the section titled, “Preparing the Generator for Use,” of this manual have been correctly completed. If unsure about how to perform any of these steps, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time for customer service.

Disconnect all electrical loads from this generator before attempting to start.

To start this generator:

1.Confirm that there are no electrical devices connected to this generator. Connected devices may increase the difficulty in starting the engine.

2.Confirm that this generator is properly grounded. (See “Ground the Generator” section of this manual.)

3.Turn the fuel valve to the “on” position.

4.Move the choke lever to the “closed” position.

5.Set the engine switch to the “on” position.

6.Slowly pull on the recoil starter handle, shown in Figure 4, until a slight resistance is felt. Then pull briskly to start the engine. Gently return the cord into the generator to avoid damage to the starter or housing. Never allow the cord to snap back.

7.If the engine fails to start, repeat step 6. NOTE: After repeated attempts to start the engine, consult the troubleshooting guide before attempting again. If problems persist, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time.

8.Once the engine has started and runs for about a minute, move the choke lever approximately half way towards the “open” position. Wait an additional 30 seconds and then move the choke lever completely over to the “open” position.

9.Allow this generator to run for several minutes before connecting any electrical devices.

Figure 4

The Recoil Start is located on the side of the generator.

GEN3250 3250 Surge Watts/2500 Running Watts Portable Generator

13

Image 13
Contents Portable Generator Features Table of Contents Recognize Safety SYMBOLS, Words and Labels Legal Requirements Important Safety InstructionsPage Page Page Generator Components Package ContentsPreparing the Generator for USE Using this Generator for the First-TimeAdd Gasoline Verify Oil Level Subsequent Use of this GeneratorStarting the Generator AC Usage Using the GeneratorDo not connect 50Hz or 3-phase loads to this generator DC Usage Some Notes about Power CordsRecommended Maintenance Schedule MAINTENANCE/CARECleaning the Generator Stopping the GeneratorChanging/Adding Oil Checking the Oil LevelSpark Plug Maintenance Air Filter MaintenanceEmptying the Fuel Tank Troubleshooting STORAGE/TRANSPORT ProceduresGovernor Screw Without Using GEN3250 3250 Surge Watts / 2500 Running Watts Parts Diagram GEN3250 3250 Surge Watts / 2500 Running Watts Parts List Page Name Amount