Buffalo Tools GEN3250 instruction manual Checking the Oil Level, Changing/Adding Oil

Page 18

Checking the Oil Level

It is important to check the oil level in the engine crankcase before each use to ensure that there is a sufficient quantity.

To check the oil level:

1.Verify that this generator is shut down and on a level surface.

2.Unscrew the oil filler/dipstick cap from the engine.

3.With a dry cloth, wipe the oil off of the dipstick that is located on the inside of the cap.

4.Insert the dipstick as if replacing the cap and then remove again. There should be oil on the dipstick. If there is no oil on the dipstick, or oil is visible only at the very end of the dipstick, add oil until the engine crankcase is filled.

5.Confirm that the oil filler/dipstick cap is properly in place when finished verifying the oil level.

Changing/Adding Oil

The oil level in this generator should be checked before each use. (See Figure 9.) When the oil level is low, add oil until the level is sufficient to operate this generator.

The oil capacity for this Model GEN3250 Portable Generator engine is 20.0 fluid oz. (0.60 L).

To drain the oil from this generator:

The oil should be changed after the first 20 hours of operation. The oil should then be changed every 6months, or for every 100 hours of use time, or when it has become contaminated with water and/or dirt.

1.Place a bucket underneath this generator to catch oil as it drains.

2.Unscrew the oil drain plug located on the crankcase underneath the oil filler/dipstick cap.

3.Allow all the oil to drain from this generator.

4.Replace the oil drain plug and tighten.

NOTE: Never dispose of used motor oil in the trash, down a drain or on the ground. Put oil in a sealed container and contact your local recycling center or auto garage to arrange oil disposal.

To add oil to the engine crankcase:

1.Confirm that this generator is on a level surface.

2.Unscrew the oil filler/dipstick cap from the engine as illustrated in Figure 8 below.

3.Using a funnel, add high detergent motor oil to fill the engine crankcase to the correct quantity. SAE10W-30 oil is recommended for general use. When the engine crankcase is full, the oil level should reach the lower lip of the oil filling opening as shown in Figure 8.

Oil Capacity (fluid oz./L)

20.0 / 0.60

Oil Type Recommended

High Detergent Motor Oil, SAE10W-30

Figure 8 – Adding oil

GEN3250 3250 Surge Watts/2500 Running Watts Portable Generator

18

Image 18
Contents Portable Generator Features Table of Contents Recognize Safety SYMBOLS, Words and Labels Important Safety Instructions Legal RequirementsPage Page Page Package Contents Generator ComponentsUsing this Generator for the First-Time Preparing the Generator for USEAdd Gasoline Subsequent Use of this Generator Verify Oil LevelStarting the Generator Using the Generator AC UsageDo not connect 50Hz or 3-phase loads to this generator Some Notes about Power Cords DC UsageCleaning the Generator MAINTENANCE/CARERecommended Maintenance Schedule Stopping the GeneratorChecking the Oil Level Changing/Adding OilAir Filter Maintenance Spark Plug MaintenanceEmptying the Fuel Tank STORAGE/TRANSPORT Procedures TroubleshootingGovernor Screw Without Using GEN3250 3250 Surge Watts / 2500 Running Watts Parts Diagram GEN3250 3250 Surge Watts / 2500 Running Watts Parts List Page Name Amount