Engine will not start. | Gas is not getting to carburetor. | Make sure gas is getting to the carburetor. |
|
| Remove the carburetor and turn the drain |
|
| screw counter clockwise. Don’t remove |
|
| completely. |
Engine will not start. | Two wires on the back of the switch may be | Make sure two wires on the back of the switch |
| disconnected. | are connected. |
Engine runs but there is no electrical output. | Reset button is "off." | Push reset button to "on." |
| Bad connecting wires/cables. | Try a different extension cord. |
| Bad electrical device connected to generator. | Disconnect device, try connecting another |
|
| device. |
| Generator is overloaded. | Reduce draw on generator to within this |
|
| generator's rated wattage by reducing number |
|
| of connected electrical devices. |
Generator starts but won’t stay running | Choke is in On position, or gas is empty. | Make sure that after it is started, move the |
|
| Choke to the off position. Make sure at least |
|
| one inch of gas is in the tank. |
Generator starts but won’t stay running | Carburetor needs to be reset | Adjust the fuel screw on the carburetor. Turn |
|
| the screw clockwise until it bottoms out, then |
|
| turn it counter clockwise 2 |
|
| resetting the air and gas flow ratio. |
Generator runs but does not support all | Short in one of the connected devices. | Disconnect any faulty or |
connected electrical devices. |
| electrical loads. |
| Air filter is dirty. | Clean or replace air filter. |
|
|
|
If the engine starts and runs, but does not | Governor screw needs adjusting. | Plug in voltmeter on VAC. See what the volts |
produce power, or power is too low. |
| are. The reading should be 110 to 120. If it is |
|
| too high or too low, adjust the governor screw, |
|
| which is located above the pull start (on the red |
|
| metal shroud). WARNING – DO NOT ADJUST |
|
| THE GOVERNOR SCREW WITHOUT USING |
|
| A VOLTMETER. YOU NEED A |
|
| VOLTMENTER. ONLY ATTEMPT THIS IF |
|
| YOU HAVE A VOLTMETER AND ARE |
|
| FAMILIAR WITH USING IT. IT COULD CAUSE |
|
| DAMAGE TO PERSONAL PROPERTY. Turn it |
|
| clockwise to turn volts up and kick the idle up. |
|
| You may have to compensate for the increased |
|
| idle from the governor screw with the idle |
|
| screw. |
GEN3250 3250 Surge Watts/2500 Running Watts Portable Generator | 21 |