Crown Audio 140MPA operation manual Troubleshooting, Vice Center for servicing

Page 14

Commercial Audio Series Mixer-Amplifiers

4 Troubleshooting

CONDITION: No power to the mixer-amplifier.

POSSIBLE REASON:

• The mixer-amplifier’s Power switch is off.

• The mixer-amplifier is not plugged into the power receptacle.

• The mixer-amplifier’s high-voltage power sup- ply circuit breaker has tripped. Verify that the AC mains voltage is correct, then press the Reset button on the back panel.

CONDITION: Distorted sound.

POSSIBLE REASON:

• Input signal level is too high. Turn down your input volume controls. NOTE: Your mixer- amplifier should never be operated at a level which causes the Clip LEDS to illuminate con- stantly.

• Master volume level is too high. Turn it down to about 3/4 of maximum level.

 

CONDITION: No sound.

 

POSSIBLE REASON:

 

• The amplifier is in “fault” mode. A Fault status

[NO GRAPHIC IS NEEDED

can be triggered when one of the amplifier’s

protection circuits is activated. First disconnect

HERE]

your speakers from the affected channel(s) one

 

by one to determine if one of the loads is

 

shorted. If an amplifier channel has a thermal

 

fault, there will be no indication on the front

 

panel, but the amp will recover after cooling. If

 

operation does not return to normal after

 

restarting your amp, press the Reset button on

 

the back of the unit. If that does not work, return

 

the unit to Crown or an authorized Crown Ser-

 

vice Center for servicing.

• No input signal.

• Input signal level is very low.

KEY

LED OFF

LED ON

page 14

Operation Manual

Image 14
Contents Commercial Audio Series Some models may be exported under the name AmcronImportant Safety Instructions Use only with a cart, stand, tripod, bracket, orCrown International, Inc Safety StandardDeclaration of Conformity European Representative’s Name and AddressTable of Contents Features WelcomePower Switch Pushbutton on-off switch Front Panel Controls and IndicatorsPower Indicator Blue LED indicates power on Input 4 Section Back Panel Controls, Connectors and Indica- torsAC Power Inlet Detachable IEC Priority Section Input 3 SectionHow to Attach Rack Ears SetupInstallation Locate the two rack ears and two rack-ear screws suppliedChoose Input Wire and Connectors Mic/Line Connectors Amp Input Connectors41-60 ft Choose Output Wire and Connectors26-40 ft Music-On-Hold ConnectionsLink In/Out Switch Wire Your SystemPhantom Power How to link another mixer to the 140MPARemote Volume Control 12 Wiring a 1-VCAP Level Control to the Output VCA ConnectorPriority Ducking Powering UpOperation Music-On-HoldVice Center for servicing TroubleshootingNo input signal Input signal level is very low Specifications KHz with 0.5% THDService Warranty 12/01Worldwide Except USA & Canada Fax Mo/day/yrThis page Intentionally Left Blank ‰ Personal/Consumer ‰ Business/Corporate ModelIndividual or Business Name Phone # Fax # Commercial Audio Series Mixer-Amplifiers Commercial Audio Series Mixer-Amplifiers