BATTERY INSTALLATION

Minimum recommended battery size is a BCI Group 26 with a minimum of 550 CCA (Cold Cranking Amps). Place the battery in the battery rack as shown and secure using the holddown hardware provided.

Once the battery has been placed and tied down with the battery hold down bar, connect the leads to the respective battery post. Always connect the (red) positive cable first and the negative (black) cable last. When disconnecting remove negative cable first and then positive lead last.

Note: The battery charger will automatically charge

the battery to keep a full charge. This charger is connected to your normal electrical supply to keep your battery charged while the generator is idle.

The charger is not intended to recharge a battery which has become completely discharged.

When replacing batteries, use the same number and the following type batteries: BCI Group 26 vented battery.

The nominal voltage rating of the battery supply is 12 volts.

BATTERY SAFETY INSTRUCTIONS

Servicing of batteries are to be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.

WARNING

Lead-acid batteries present a risk of fire because they generate hydrogen gas. The following procedures are to be followed:

Do not smoke when near batteries.

Do not cause flame or spark in battery area.

Discharge static electricity from body before touching batteries by first touching a grounded metal surface.

Do not dispose of batteries in a fire. The battery is capable of exploding.

Do not open or mutilate the battery or batteries. Released electrolyte has been known to be harmful to the skin and eyes and to be toxic.

WARNING

The electrolyte is a dilute sulfuric acid that is harmful to the skin and eyes. It is electrically conductive and corrosive. The following procedures are to be observed.

Wear full eye protection and protective clothing.

Where electrolyte contacts the skin, wash it off immediately with water.

Where electrolyte contacts the eyes, flush thoroughly and immediately with water and seek medical attention.

Spilled electrolyte is to be washed down with and acid neutralizing agent. A common practice is to use a solution of one pound (500 grams) bicarbonate of soda to one gallon (4 liters) of water. The bicarbonate of soda solution is to be added until the evidence of reaction (foaming) has ceased. The resulting liquid is to be flushed with water and the area dried.

CAUTION

A battery presents a risk of electrical shock and a high short circuit current. The following precautions are to be observed when working on batteries:

Remove watches, rings or other metal objects.

Use tools with insulated handles.

Wear rubber gloves.

Do not lay tools or metal parts on top of batteries.

Disconnect charging source prior to connecting or disconnecting battery terminals.

Determine if the battery is inadvertently grounded. When inadvertently grounded, remove source of ground. Contact with any part of a grounded battery is capable of resulting in electrical shock. The risk of such shock is reduced when such grounds are removed during installation and maintenance.

Failure to connect and disconnect in the proper sequence can cause equipment damage. Ensure there is a clean tight fit from the cables to the post.

12

Image 12
Contents English Francais EspañolTable of Contents General Safety Guidelines General Safety Guidelines Introduction Unpacking Instructions Risk of Electrocution AND/OR InjuryRisk of Injury and Being Crushed Generator Specifications Engine SpecificationsFuel Specifications DimensionsInstallation Drawings Installation Location and Generator PlacementLocation and Generator Placement Wiring Installation DetailCarburetor Adjustments Natural GAS NG SettingsFuel Selection Fuel RequirementsAutomatic Transfer Switch Battery Installation Battery Safety InstructionsLubrication and Cooling Initial Start UP of UnitPrestart Checks Initial Test of the SystemGenerator Control Panel Features Display Mode Alternate Display ModeMenu Mode Generator Control Panel OperationGenerator Control Panel Features Alarms Generator Control Panel Features PRE-ALARMS25KW Wiring Diagram CP500 Controller 25KW Wiring Diagram CP1000 Controller Engine Maintenance Generator MaintenanceTroubleshooting Symptom Possible Cause Corrective ActionCoverage Maintenance LOG Parts Drawing Exhaust System Parts Drawing Enclosure Parts Drawing Cooling System Parts Drawing Door Assembly X 1/2 NPT 064-0069 Parts Drawing Generator Parts Drawing 25KW Breakdown Article Pièce N 061-0188 Parts Drawing Battery Hold Down

PM402511 specifications

The Coleman PM402511 is an innovative and versatile portable generator designed to meet the power demands of outdoor adventures, home backup, and job sites. Renowned for its reliability and efficiency, the PM402511 is an ideal solution for users seeking convenience in a compact form.

One of the standout features of the Coleman PM402511 is its impressive 4000 watts of starting power and 3500 watts of running power. This capacity makes it suitable for powering essential appliances, tools, and devices. Whether you need to keep your refrigerator running during a power outage or power up your tools on a construction site, this generator provides a dependable energy source.

The PM402511 is equipped with an advanced inverter technology that produces clean and stable energy. This feature is especially vital for powering sensitive electronics like laptops and smartphones, as it minimizes the risk of damaging fluctuations in voltage. With its ability to deliver pure sine wave power, users can operate their devices with confidence.

Another significant characteristic of the Coleman PM402511 is its lightweight and compact design. Weighing only around 50 pounds, it is incredibly portable, allowing users to easily transport it to campsites, tailgating events, or remote job locations. The generator’s foldable handles enhance its portability, making it easy to maneuver and store when not in use.

Fuel efficiency is a crucial aspect of any generator, and the PM402511 excels in this regard. With a runtime of up to 8 hours on a 2.6-gallon fuel tank, it can keep your devices powered without the constant need for refueling. Additionally, its quiet operation makes it a great choice for outdoor environments, ensuring that you can enjoy nature without disturbing the peace.

User-friendly controls and proper safety features further enhance the experience with the Coleman PM402511. It includes multiple outlets, including 120V AC outlets and USB ports, allowing you to charge devices simultaneously. Furthermore, it has built-in safety features such as overload protection and low-oil shutdown, ensuring the generator remains safe during operations.

In summary, the Coleman PM402511 is a powerful, efficient, and portable generator that caters to a variety of power needs. With its advanced inverter technology, excellent fuel efficiency, lightweight construction, and safety features, it stands out as an excellent choice for anyone in need of reliable energy on the go.