Coleman PM402511 owner manual Generator Control Panel Features Alarms

Page 16

GENERATOR CONTROL PANEL

FEATURES - ALARMS

When the generator control panel senses an abnormal operating condition, an alarm is declared and the generator set is shutdown. All alarm conditions will light a red LED (labeled Alarm) along with displaying the condition on the LCD screen. When an alarm condition occurs, the display indicates the cause of the alarm and the fuel solenoid contact opens which shuts down the engine. Resetting alarms can only be done locally by setting the Auto/Off/Run switch to the OFF position.

OVERCRANK ALARM

During unit start-up the controller performs a cyclic cranking procedure. At that time, the common alarm contacts close and the LCD displays the message OVERCRANK and the current overcrank setting.

OVERSPEED ALARM

If the generator speed exceeds a pre-programmed speed, an overspeed alarm is displayed. At that time, the common alarm contact closes and the LCD displays the message OVERSPEED and the current overspeed setting.

HIGH COOLANT TEMPERATURE ALARM

If the engine coolant temperature exceeds a factory set level an alarm occurs. At that time, the common alarm contact closes and the LCD displays the message HIGH COOLANT TEMP and the current high coolant temperature setting.

WARNING

Hot coolant under pressure in radiator can cause severe burns. Allow radiator to cool completely before removing cap.

Eye protection should be used.

LOW OIL PRESSURE ALARM

If the oil pressure decreases below the low oil pressure alarm setting programmed, an alarm occurs. At that time, the common alarm contact closes and the LCD displays the message LOW OIL PRESSURE and the current low oil pressure alarm setting.

ENGINE SENDER FAULT ALARM

If an engine sender (transducer) fails, an alarm is displayed. At that time, the common alarm contact closes and the LCD displays the message SENDER FAILURE and the failed sender type.

LOW COOLANT LEVEL ALARM

This alarm will shut down the engine when a loss of coolant is detected via an optional low coolant level sensor. At that time, the common alarm contact closed and the LCD displays the message LOW COOLANT LEVEL.

GENERATOR CONTROL PANEL

FEATURES - PRE-ALARMS

All pre-alarm conditions illuminate the red alarm LED with a 50% duty cycle at a frequency of 0.5 hertz and sounding the optional audible alarm at the same rate. The LCD displays all pre-alarms in the following manner: Low Oil Pressure, High Coolant Temperature, and Battery Voltage pre-alarms are shown on the main display with their current values alternately flashing. All other pre-alarms are individually displayed in sequence, using the alternate main display mode, whereby each pre-alarm value is alternately flashed. All pre-alarmed parameters are displayed in this manner before non-pre- alarmed parameters. All pre-alarms are reset by correcting the cause of the pre-alarm. Audible pre-alarms can be reset by the Alarm Silence pushbutton.

HIGH COOLANT TEMPERATURE PRE-ALARM

If engine coolant temperature increases above the high coolant temperature pre-alarm setpoint, a pre-alarm occurs.

LOW COOLANT TEMPERATURE PRE-ALARM

If engine coolant temperature decreases below the low coolant temperature pre-alarm setpoint, a pre-alarm occurs.

WEAK BATTERY PRE-ALARM

If the battery voltage drops below 60% of the nominal voltage for more than 2 seconds during engine cranking,

apre-alarm occurs. The message Weak Battery is displayed in the alternate display mode and is reset by scrolling through the alternate display.

LOW BATTERY VOLTAGE PRE-ALARM

If the battery voltage decreases below the low battery voltage value programmed, a pre-alarm occurs.

BATTERY OVER VOLTAGE PRE-ALARM

If the battery voltage exceeds the battery over voltage value programmed, a pre-alarm occurs.

ENGINE OVERLOAD PRE-ALARM

If the engine load exceeds the engine overload level pre-alarm value programmed, a pre-alarm occurs.

MAINTENANCE PRE-ALARM

When the next scheduled maintenance timer reaches zero hours, a pre-alarm occurs. After the required maintenance is performed, the pre-alarm can be cleared from the front panel. To clear the pre-alarm from the front panel, go to the alternate display mode and scroll to the screen that displays HRS TO NEXT SERVICE. Pressing the Select/Enter button while on this screen will clear the maintenance pre-alarm and reset the maintenance timer back to its programmed starting value.

16

Image 16
Contents English Francais EspañolTable of Contents General Safety Guidelines General Safety Guidelines Risk of Electrocution AND/OR Injury Introduction Unpacking InstructionsRisk of Injury and Being Crushed Generator Specifications Engine SpecificationsFuel Specifications DimensionsInstallation Drawings Installation Location and Generator PlacementLocation and Generator Placement Wiring Installation DetailCarburetor Adjustments Natural GAS NG SettingsFuel Selection Fuel RequirementsAutomatic Transfer Switch Battery Installation Battery Safety InstructionsLubrication and Cooling Initial Start UP of UnitPrestart Checks Initial Test of the SystemGenerator Control Panel Features Display Mode Alternate Display ModeMenu Mode Generator Control Panel OperationGenerator Control Panel Features Alarms Generator Control Panel Features PRE-ALARMS25KW Wiring Diagram CP500 Controller 25KW Wiring Diagram CP1000 Controller Engine Maintenance Generator MaintenanceTroubleshooting Symptom Possible Cause Corrective ActionCoverage Maintenance LOG Parts Drawing Exhaust System Parts Drawing Enclosure Parts Drawing Cooling System Parts Drawing Door Assembly X 1/2 NPT 064-0069 Parts Drawing Generator Parts Drawing 25KW Breakdown Article Pièce N 061-0188 Parts Drawing Battery Hold Down

PM402511 specifications

The Coleman PM402511 is an innovative and versatile portable generator designed to meet the power demands of outdoor adventures, home backup, and job sites. Renowned for its reliability and efficiency, the PM402511 is an ideal solution for users seeking convenience in a compact form.

One of the standout features of the Coleman PM402511 is its impressive 4000 watts of starting power and 3500 watts of running power. This capacity makes it suitable for powering essential appliances, tools, and devices. Whether you need to keep your refrigerator running during a power outage or power up your tools on a construction site, this generator provides a dependable energy source.

The PM402511 is equipped with an advanced inverter technology that produces clean and stable energy. This feature is especially vital for powering sensitive electronics like laptops and smartphones, as it minimizes the risk of damaging fluctuations in voltage. With its ability to deliver pure sine wave power, users can operate their devices with confidence.

Another significant characteristic of the Coleman PM402511 is its lightweight and compact design. Weighing only around 50 pounds, it is incredibly portable, allowing users to easily transport it to campsites, tailgating events, or remote job locations. The generator’s foldable handles enhance its portability, making it easy to maneuver and store when not in use.

Fuel efficiency is a crucial aspect of any generator, and the PM402511 excels in this regard. With a runtime of up to 8 hours on a 2.6-gallon fuel tank, it can keep your devices powered without the constant need for refueling. Additionally, its quiet operation makes it a great choice for outdoor environments, ensuring that you can enjoy nature without disturbing the peace.

User-friendly controls and proper safety features further enhance the experience with the Coleman PM402511. It includes multiple outlets, including 120V AC outlets and USB ports, allowing you to charge devices simultaneously. Furthermore, it has built-in safety features such as overload protection and low-oil shutdown, ensuring the generator remains safe during operations.

In summary, the Coleman PM402511 is a powerful, efficient, and portable generator that caters to a variety of power needs. With its advanced inverter technology, excellent fuel efficiency, lightweight construction, and safety features, it stands out as an excellent choice for anyone in need of reliable energy on the go.