AK Series w/K60 Control Owners Manual | page 3 |
|
|
SECTION 5: TROUBLE SHOOTING GUIDE
The troubleshooting guide is meant as a general aid only. There are no user serviceable parts in the generator. All repairs should be performed by a qualified service person. For additional assistance or the factory authorized service person nearest you call: AMEREC's Service Department at
SYMPTOMS | PROBABLE CAUSES | ACTION TO BE TAKEN | |
|
|
| |
Control won't turn "ON". | Improper power supplied (no power). | 1. a. Make sure circuit breaker is "ON". | |
(Control light off). | or | b. Using a voltmeter, check the voltage across the two fuses on the "PCA" | |
| Control improperly connected. |
| printed circuit assembly. Voltage should be 208V / 240V. |
| or | c. Check fuses, if the fuse(s) are blown, replace with Buss# | |
| Control cable is faulty. |
| MDL 15/100 or equivalent fuse. If the fuse blows again - call AMEREC's |
| or |
| Service Department. |
| Contol is faulty. | 2. Check control(s) installed per Section | |
|
| ||
|
|
| SERVICE INSTRUCTIONS. |
|
| 3. Replace control cable - call AMEREC's Service Department. | |
|
| 4. Replace the control - Call AMEREC's Service Department. | |
|
|
|
|
Control "OFF". | Generator is faulty. | 1. | Turn off the circuit breaker. |
Unit still makes steam. |
| 2. | Call AMEREC's Service Department. |
|
| ||
|
|
|
|
Water runs out of steam head. | Generator is faulty. | 1. | Turn off the circuit breaker. |
|
| 2. | Turn off the water. |
|
| 3. | Call AMEREC's Service Department. |
|
|
|
|
Steam room too hot or cold. | Temperature adjustment needs setting. | 1. | See Section 3, "Temperature Adjustment". |
|
| 2. | Call AMEREC's Service Department. |
|
|
| |
Control "ON". | Temperature sensor not connected. | 1. Check that the sensor cable is connected to J4 on the PCA printed circuit | |
K60 Control displays "E001". |
| assembly. | |
|
| 2. Check the cable connection to the temperature sensor. | |
|
| 3. Replace sensor and/or cable - call AMEREC's Service Department. | |
|
|
| |
Control "ON". | Temperature sensor. | 1. Check sensor cable for damage from nail/staple puncture. | |
K60 Control displays "E002". | or |
|
|
| cable shorted. | 2. Check sensor cable ends for frayed/exposed wire strands. | |
|
| 3. Replace sensor and/or cable - call AMEREC's Service Department. | |
|
|
| |
Control "ON". | Steambath temperature over 132 º. | 1. If bath is too hot, shut off circuit breaker and call AMEREC's Service Department. | |
K60 Control displays ">>>º". | or |
|
|
| Sensor/cable is faulty. | 2. | Treat as "E002" fault above. |
|
|
|
|
Control won't turn "OFF". | Control is faulty. | 1. | Replace the control - call AMEREC's Service Department. |
(Control light on). |
|
|
|
|
|
|
|
Control "ON". (Control light on) | Unit has not filled completely. | 1. | Wait at least 10 minutes after turning on the control. |
Unit won't steam. | or |
|
|
Note: Time/Temp properly. | Generator is faulty. | 2. | Call AMEREC's Service Department. |
|
|
| |
displayed on K60. |
|
|
|
|
|
| |
Unable to adjust Time or Temp | Control is faulty. | 1. Replace control - call AMEREC's Service Department. | |
setting with K60. | or |
|
|
| Generator is faulty. | 2. Replace PCA - call AMEREC's Service Department. | |
|
|
|
|
Sudden increases in rate water | Foaming contaminants in the water | 1. | Flush tank 3 times. See Section 4. |
sputters out of steam head. | supply. |
|
|
|
|
|
|