Amerec AK10, AK7, AK5 Steam Generator Overview Celsius and 24 Hour Options, Taking a Steambath

Page 2

AK Series w/K60 Control Owners Manual

page 2

 

 

SECTION 1A: STEAM GENERATOR OVERVIEW

The standard K60 model steam generator control features an adjustable 60 minute time and tem- perature control with digital display. The actual room temperature and time remaining are alter- nately displayed every 5 seconds. The primary control can be mounted either inside or outside

the steam room and an optional secondary control is available to mount in an alternate location. The temperature can be adjusted in a range between 100 degrees and 125 degrees Fahrenheit with an initial default of 120 degrees. Once the set temperature is reached the ''soft

steam'' feature automatically engages cutting steam production back to a single element to provide softer billowing steam during more of the steam bath. If the steam room temperature drops more than 5 degrees both elements will automatically engage.

SECTION 1B: STEAM GENERATOR OVERVIEW - CELSIUS AND 24 HOUR OPTIONS

As an option your K60 control can be ordered with a Celsius and/or 24 hour timer in place of the Fahrenheit and 60 minute standard. The Celsius option's adjustable temperature range is be- tween 38 degrees and 52 degrees Celsius, with

an initial default of 49 degrees. The 24 hour timer option is adjustable in 1 hour increments from 1 to 24 hours. Other features of the K60 control should operate as described in section 2 below with the above noted exceptions.

SECTION 2: OPERATION OF YOUR K60 CONTROL

1.Be sure the power circuit and water supply to the generator are on.

2.Press the ON/OFF button on the control until the temperature is displayed.

3.The generator should produce steam in 5 to 10 minutes and will turn off automatically in 60 minutes or less depending on the set time. The control will alternately display time remaining and the actual temperature at the sensor in your steam room every 5 seconds.

4.To change the time setting press and hold the TIME button on the control. Continuing to hold the button will cause the time to increase in 5 minute increments from the prior setting. At 60 minutes the time setting will scroll backwards to

5minutes. To shut down the generator press the ON/OFF button.

5.To change the preset temperature setting press and hold the TEMP button on the control. While continuing to hold the button, the tempera- ture display will increase in 1 degree increments

from the prior setting to 125 degrees Fahrenheit. At 125 degrees Fahrenheit the temperature set- ting will decrease in 1 degree increment to the lowest setting, 100 degrees Fahrenheit.

6.The TIME and TEMP set points are remem- bered by the K60 for your next bath unless power to the steam generator is lost.

SECTION 3: TAKING A STEAMBATH

1.Wait for the steam room to reach a comfort- able temperature.

2.Remove clothing and jewelry.

3.Enter the steam room and close the door to prevent steam from escaping.

4.Relax and enjoy the warm steam releasing tense muscles and refreshing the entire body.

5.If your steam room has a shower a pleasant experience can be achieved by taking a warm shower with the steam.

6.After a steambath a warm shower will give you a feeling of relaxation and is conducive to a good night’s rest. A cold shower will refresh you and is a good way to start a busy day or prepare you for an evening out.

SECTION 4: MAINTENANCE OF YOUR AK STEAM GENERATOR

The steam generator, steam head, fittings and

Flushing Procedures:

plumbing connections should be inspected regu-

 

 

larly for water leaks and damage. The AK steam

1.

The generator should be cool.

generator is equipped with a manual drain valve

 

 

for flushing sediments from the generator tank.

2.

Press the control ON.

This procedure should be scheduled monthly or

 

 

more often depending on local water conditions

3.

Open the manual drain valve.

and steam bath usage.

 

 

4.The unit will drain without heating the water.

5.Allow the water to run for a full 10 minutes.

6.Push the control OFF. When the water stops flowing out the drain, close the manual drain valve.

4209-24 12-09-02

Image 2
Contents Do not hesitate to call our Service Department at Amerec Steambath GeneratorsSteam Generator Overview Celsius and 24 Hour Options Maintenance of Your AK Steam GeneratorSteam Generator Overview Operation of Your K60 ControlTrouble Shooting Guide Symptoms Probable Causes Action to be Taken3635