Briggs & Stratton 030248-0 manual Storage

Page 19

Storage

The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following guidelines to prepare it for storage.

Generator Storage

Clean the generator as outlined in Cleaning.

Check that cooling air slots and openings on generator are open and unobstructed.

Long Term Storage Instructions

Fuel can become stale when stored over 30 days. Stale fuel causes acid and gum deposits to form in the fuel system or on essential carburetor parts. To keep fuel fresh, use Briggs

&Stratton FRESH START™ fuel stabilizer, available as a liquid additive or a drip concentrate cartridge.

There is no need to drain gasoline from the engine if a fuel stabilizer is added according to instructions. Run the engine for 2 minutes to circulate the stabilizer throughout the fuel system. The engine and fuel can then be stored up to

24 months.

If gasoline in the engine has not been treated with a fuel stabilizer, it must be drained into an approved container. Run the engine until it stops from lack of fuel. The use of a fuel stabilizer in the storage container is recommended to maintain freshness.

WARNING

Fuel and its vapors are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK

Store away from furnaces, stoves, water heaters, clothes dryers or other appliances that have pilot light or other ignition source because they can ignite fuel vapors.

WHEN DRAINING FUEL

Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

Drain fuel tank outdoors.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

DO NOT light a cigarette or smoke.

Change Oil

While engine is still warm, drain oil from crankcase. Refill with recommended grade. See Changing Engine Oil.

Oil Cylinder Bore

Remove spark plug and pour about 1/2 ounce (15 ml) of clean engine oil into the cylinder.

Install spark plug and pull starter handle slowly to distribute oil.

WARNING

Unintentional sparking can result in fire or electric shock.

• NEVER crank engine with spark plug removed.

Other Storage Tips

1.DO NOT store fuel from one season to another unless it has been treated as described in Long Term Storage Instructions.

2.Replace fuel container if it starts to rust. Rust and/or dirt in fuel can cause problems if it’s used with this unit.

3.Cover unit with a suitable protective cover that does not retain moisture.

WARNING

Storage covers can be flammable.

DO NOT place a storage cover over a hot generator.

Let equipment cool for a sufficient time before placing the cover on the equipment.

4.Store generator in clean, dry area.

17

Image 19
Contents Operator’s Manual Date Purchased Where to Find UsGenerator EngineTable of Contents Equipment Description Operator SafetySafety Rules Safety alert symbol is used with a signal wordBroken bones, fractures, bruises, or sprains could result Engine exhaust from this product containsContact with muffler area can result in serious burns When Testing for Engine SparkUnintentional sparking can result in fire or electric shock Unpack Generator AssemblyInstall Wheel Kit Shipment ContentsHigh Altitude Add Engine OilAdd Fuel Fuel must meet these requirementsSpecial Requirements Connecting to a Building’s Electrical SystemSystem Ground Generator LocationItems Not Shown Features and ControlsVolt AC, 20 Amp, Duplex Receptacles Cord Sets and ReceptaclesNema L14-20 120/240 Volt AC, 20 Amp, Locking ReceptacleStarting the Engine OperationStopping the Engine Connecting Electrical LoadsMove fuel valve to Off position Wattage Reference Guide Don’t Overload GeneratorMaintenance Schedule MaintenanceGenerator Maintenance Oil Engine MaintenanceService Spark Arrester Service Air CleanerService Spark Plug Install spark plug and tighten firmlyAir Cooling System Carburetor AdjustmentStorage Troubleshooting Owner’s Warranty Responsibilities Emissions Control System WarrantyWarranties Emission Information MaintenanceClaims and Coverage Exclusions Limited Warranty 800 Product SpecificationsCommon Service Parts AC Load CurrentManual del Operario Fecha de compra Dónde encontrarnosGenerador MotorControles y características Resolución de problemas GarantíasSeguridad de Operario MontajeSímbolos de peligro y sus significados Seguridad de operarioDescripción del equipo Reglas de seguridadCuando Transporte O Repare EL Equipo Cuando Anada Combustible O Vacíe EL DepósitoCuando Ponga EN Funcionamiento EL Equipo Cuando Opere EL EquipoCuando Pruebe LA Bujía DEL Motor Cuando Ajuste O Haga Reparaciones a SU Máquina GeneradorContenido de la caja MontajeDesembalaje del generador Instale el juego de ruedasCuando Anada Combustible Agregar aceite al motorEvite el daño del generador Gran altitudRequisitos especiales Tierra del sistemaConexión al sistema eléctrico de un edificio Ubicación del generadorAmperios, monofásica de 60 Hz Controles y característicasTomas eléctricas dobles de 120 V CA y 20 a Juegos de cordones y enchufes conectores120/240 Voltios AC, 20 Amperios, Receptáculo de Seguridad Tierra VerdeEncienda el motor OperandoGire la válvula de combustible blanca hasta la posición Off Conexión de cargas eléctricasParada del motor El motor podría petardear, incendiarse o dañarseControl de la energía No sobrecargar el generadorCapacidad EjemploPlan de mantenimiento MantenimientoMantenimiento del Generador Adición de Aceite del Motor Mantenimiento del MotorAceite Recomendaciones sobre el aceite Comprobación del Nivel de AceiteLimpie la Pantalla Apagachispas Servicio del depurador de aireLimpia B Servicio del bujíaSistema de refrigeración de aire Limpie e inspeccione el apagachispas de la siguiente maneraAjuste del Carburador Almacenamiento Problemo Causa Accion Resolución de problemasOperaciones de mantenimiento que se enumeran en las GarantíasGarantía del sistema de control de emisiones Responsabilidades de la garantía del propietarioInformación sobre emisiones Garantía Limitada Servicio común despide Especificaciones del productoCorriente Carga de C.A