Briggs & Stratton 030248-0 Product Specifications, Common Service Parts, AC Load Current, 800

Page 24

Portable Generator

Product Specifications

Starting Wattage . . . . . . . . . . . . . . . . . . . . . . . .4,800 watts Wattage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3,500 watts

AC Load Current:

at 120 Volts . . . . . . . . . . . . . . . . . . . . . . . . . . .29.1 Amps at 240 Volts . . . . . . . . . . . . . . . . . . . . . . . . . . .14.5 Amps

Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-phase Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . . .60 Hertz Shipping Weight . . . . . . . . . . . . . . . . . . . . . .130 lb (59 kg) Displacement (Model 030348) . . . . . . . . 12.48 ci (206 cc) Displacement (Model 030208) . . . . . . . . 15.22 ci (249 cc) Spark Plug Gap . . . . . . . . . . . . . . . . . . 0.030 in (0.76 mm) Fuel Capacity . . . . . . . . . . . . . . . . . . . 4 U.S. gallons (15 L) Oil Capacity . . . . . . . . . . . . . . . . . . .20 Ounces (0.6 Liters)

Common Service Parts

Air Cleaner . . . . . . . . . . . . . . . . . . . . . . .491588S or 5043D

Resistor Spark Plug . . . . . . . . . . . . . . . . . . . . . . .491055S

Long Life Platinum Spark Plug . . . . . . . . . . . . . . . . .5066D

Engine Oil Bottle . . . . . . . . . . . . . . . . . . . . . . . . . . .100005

Fuel Stabilizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5041D

Spark Arrester . . . . . . . . . . . . . . . . . . . . . . . . . . . .83083GS

Tune Up Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5121A

Power Ratings: The gross power rating for individual gas engine models is labeled in accordance with SAE (Society of Automotive Engineers) code J1940 (Small Engine Power & Torque Rating Procedure), and rating performance has been obtained and corrected in accordance with SAE J1995 (Revision 2002-05). Torque values are derived at 3060 RPM; horsepower values are derived at 3600 RPM. Actual gross engine power will be lower and is affected by, among other things, ambient operating conditions and engine-to-engine variability. Given both the wide array of products on which engines are placed and the variety of environmental issues applicable to operating the equipment, the gas engine will not develop the rated gross power when used in a given piece of power equipment (actual "on-site" or net horsepower). This difference is due to a variety of factors including, but not limited to, accessories (air cleaner, exhaust, charging, cooling, carburetor, fuel pump, etc.), application limitations, ambient operating conditions (temperature, humidity, altitude), and engine-to-engine variability. Due to manufacturing and capacity limitations, Briggs & Stratton may substitute an engine of higher rated power for this Series engine.

Briggs & Stratton Power Products Group, LLC

900 N. Parkway

Jefferson, Wisconsin, 53549 U.S.A.

22

(800) 743-4115

BRIGGSandSTRATTON.COM

 

Image 24
Contents Operator’s Manual Where to Find Us GeneratorEngine Date PurchasedTable of Contents Operator Safety Safety RulesSafety alert symbol is used with a signal word Equipment DescriptionEngine exhaust from this product contains Broken bones, fractures, bruises, or sprains could resultWhen Testing for Engine Spark Contact with muffler area can result in serious burnsUnintentional sparking can result in fire or electric shock Assembly Install Wheel KitShipment Contents Unpack GeneratorAdd Engine Oil Add FuelFuel must meet these requirements High AltitudeConnecting to a Building’s Electrical System System GroundGenerator Location Special RequirementsFeatures and Controls Items Not ShownCord Sets and Receptacles Nema L14-20120/240 Volt AC, 20 Amp, Locking Receptacle Volt AC, 20 Amp, Duplex ReceptaclesOperation Starting the EngineConnecting Electrical Loads Stopping the EngineMove fuel valve to Off position Don’t Overload Generator Wattage Reference GuideMaintenance Maintenance ScheduleGenerator Maintenance Engine Maintenance OilService Air Cleaner Service Spark PlugInstall spark plug and tighten firmly Service Spark ArresterCarburetor Adjustment Air Cooling SystemStorage Troubleshooting Emissions Control System Warranty Owner’s Warranty Responsibilities Warranties Maintenance Emission InformationClaims and Coverage Exclusions Limited Warranty Product Specifications Common Service PartsAC Load Current 800Manual del Operario Dónde encontrarnos GeneradorMotor Fecha de compraResolución de problemas Garantías Seguridad de OperarioMontaje Controles y característicasSeguridad de operario Descripción del equipoReglas de seguridad Símbolos de peligro y sus significadosCuando Anada Combustible O Vacíe EL Depósito Cuando Ponga EN Funcionamiento EL EquipoCuando Opere EL Equipo Cuando Transporte O Repare EL EquipoCuando Ajuste O Haga Reparaciones a SU Máquina Generador Cuando Pruebe LA Bujía DEL MotorMontaje Desembalaje del generadorInstale el juego de ruedas Contenido de la cajaAgregar aceite al motor Evite el daño del generadorGran altitud Cuando Anada CombustibleTierra del sistema Conexión al sistema eléctrico de un edificioUbicación del generador Requisitos especialesControles y características Amperios, monofásica de 60 HzJuegos de cordones y enchufes conectores 120/240 Voltios AC, 20 Amperios, Receptáculo de SeguridadTierra Verde Tomas eléctricas dobles de 120 V CA y 20 aOperando Encienda el motorConexión de cargas eléctricas Parada del motorEl motor podría petardear, incendiarse o dañarse Gire la válvula de combustible blanca hasta la posición OffNo sobrecargar el generador CapacidadEjemplo Control de la energíaMantenimiento Plan de mantenimientoMantenimiento del Generador Mantenimiento del Motor Aceite Recomendaciones sobre el aceiteComprobación del Nivel de Aceite Adición de Aceite del MotorServicio del depurador de aire Limpia BServicio del bujía Limpie la Pantalla ApagachispasLimpie e inspeccione el apagachispas de la siguiente manera Sistema de refrigeración de aireAjuste del Carburador Almacenamiento Resolución de problemas Problemo Causa AccionGarantías Garantía del sistema de control de emisionesResponsabilidades de la garantía del propietario Operaciones de mantenimiento que se enumeran en lasInformación sobre emisiones Garantía Limitada Especificaciones del producto Servicio común despideCorriente Carga de C.A