SPECIFICATIONS

Starting Wattage . . . . . . . . . . . . . . . . . . . . . . .4,800 watts Wattage . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3,500 watts AC Load Current:

At 120 Volts . . . . . . . . . . . . . . . . . . . . . . . . .29.2 Amps At 240 Volts . . . . . . . . . . . . . . . . . . . . . . . . .14.6 Amps Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–phase Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . .60 Hertz Fuel Tank Capacity . . . . . . . . . . . . . . . . . . . . 4 U.S. gallons Shipping Weight . . . . . . . . . . . . . . . . . . . . . . . . . . 127 lbs.

GENERAL MAINTENANCE RECOMMENDATIONS

The Owner/Operator is responsible for making sure that all periodic maintenance tasks are completed on a timely basis; that all discrepancies are corrected; and that the unit is kept clean and properly stored. NEVER operate a

damaged or defective generator.

NOTE: Should you have questions about replacing components on your BSPP generator, please call 1-800-743-4115for assistance.

Engine Maintenance

See engine owner’s manual for instructions.

CAUTION

Avoid prolonged or repeated skin contact with used motor oil.

Used motor oil has been shown to cause skin cancer in certain laboratory animals.

Thoroughly wash exposed areas with soap and water.

KEEP OUT OF REACH OF CHILDREN. DON'T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL TO COLLECTION CENTERS.

Generator Maintenance

Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves or any other foreign material.

NOTE: DO NOT use a garden hose to clean generator. Water can enter engine fuel system and cause problems. In addition, if water enters generator through cooling air slots, some of the water will be retained in voids and cracks of the rotor and stator winding insulation.Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.

WARNING

Unintentional sparking can result in fire or electric shock.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR

Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK

Use approved spark plug tester.

DO NOT check for spark with spark plug removed.

Generator Cleaning

• Use a damp cloth to wipe exterior surfaces clean.

CAUTION

Improper treatment of generator can damage it and shorten its life.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

Use a soft bristle brush to loosen caked on dirt or oil.

Use a vacuum cleaner to pick up loose dirt and debris.

Use low pressure air (not to exceed 25 psi) to blow away dirt. Inspect cooling air slots and opening on generator.These openings must be kept clean and unobstructed.

13

Image 13
Contents 030208 3500W Safety Rules Table of ContentsEquipment Description When Starting Equipment When Adding or Draining FuelWhen Operating Equipment When Transporting or Repairing EquipmentWhen Testing for Engine Spark When Adjusting or Making Repairs to Your GeneratorKnow Your Generator Install Wheel KIT AssemblyCarton Contents Remove Generator From CartonInstall fuel cap and wipe up any spilled fuel When Adding FuelBefore Starting Engine Add Engine OilConnecting to a Building’s Electrical System Using the GeneratorSystem Ground Generator LocationOperating Generator Connecting Electrical LoadsStarting the Engine Do not Overload the GENERATOR. See Don’t Overload GeneratorCold Weather Operation ReceptaclesStopping the Engine 120/240 Volt AC, 20 Amp, Locking ReceptaclePermanent Cold Weather Shelter Remove shelter when temperatures are above 40F 4CDont Overload Generator Power ManagementCapacity ExampleGeneral Maintenance Recommendations SpecificationsEngine Maintenance Generator MaintenanceGenerator Storage StorageEngine Storage Other Storage Tips Problem Cause Correction Troubleshooting3500W Portable Generator Year Consumer Use Years Years orDescripción DEL Equipo Conserve Estas Instrucciones Tabla DE ContenidosReglas DE Seguridad AdvertenciaCuando Ponga EN Funcionamiento EL Equipo Cuando Añada Combustible O Vacíe EL DepósitoCuando Opere EL Equipo Cuando Transporte O Repare EL EquipoCuando Ajuste O Haga Reparaciones a SU Generador PrecauciónCuando Pruebe LA Bujía DEL Motor Tapa del Depósito del Aceite Llene el motor con aceite Conozca SU GeneradorTomacorriente Dobles de 120 Voltios AC, 20 Amp Tomacorriente con Dispositivo de Seguridad deInstale el Juego de Ruedas MontajePara Retirar El Generador De La Caja Contenido de la CajaAgregar Aceite al Motor Antes DE Darle Arranque AL MotorAgregue Combustible Coloque la generador sobre una superficie niveladaTierra del Sistema USO DEL GeneradorUbicación del Generador Conexión al Sistema Eléctrico de un EdificioEncienda el Motor Operando EL GeneradorConexion De Cargas Electricas No Sobrecargue EL GENERADOR.Vea No Sobrecargue GeneradorOperación Durante UN Clima Frío Receptáculos PrecauciónParado Del Motor Voltios AC, 20 Amperios, Receptáculos DoblesFigura 15 Refugio Frío Permanente del Tiempo Capacidad No Sobrecargue GeneradorControl de la Energía EjemploRecomendaciones Generales DE Mantenimiento EspecificacionesMantenimiento del Motor Mantenimiento del GeneradorAlmacenando el Generador AlmacenamientoAlmacenando el Motor Otras Sugerencias Para el AlmacenandoDiagnositicos DE Averías Problemo Accion CausaGarantía Limitada