Briggs & Stratton 30220 When Adding or Draining Fuel, When Starting Equipment

Page 3

SAFETY RULES

7000W Portable Generator

PowerBOSS™

 

 

 

Using a generator indoors WILL KILL YOU IN MINUTES.

Exhaust contains carbon monoxide, a poison gas you cannot see or smell.

NEVER use in the home ONLY use outdoors and

or in partly enclosed far from open windows, areas such as garages. doors, and vents.

WARNING

Running generator gives off carbon monoxide, an odorless, colorless, poison gas.

Breathing carbon monoxide can cause nausea, fainting or death.

Operate generator ONLY outdoors.

Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings.

DO NOT operate generator inside any building or enclosure (even if doors or windows are open), including the generator compartment of a recreational vehicle (RV).

WARNING

Generator produces powerful voltage.

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.

Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.

DO NOT touch bare wires or receptacles.

DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

DO NOT operate generator in the rain or wet weather.

DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

DO NOT allow unqualified persons or children to operate or service generator.

WARNING

Fuel and its vapors are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

WHEN ADDING OR DRAINING FUEL

Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

Fill or drain fuel tank outdoors.

DO NOT overfill tank. Allow space for fuel expansion.

Wait for spilled fuel to evaporate before starting engine.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

DO NOT light a cigarette or smoke.

WHEN STARTING EQUIPMENT

Ensure spark plug, muffler, fuel cap and air cleaner are in place.

DO NOT crank engine with spark plug removed.

WHEN OPERATING EQUIPMENT

DO NOT tip engine or equipment at angle which causes fuel to spill.

This generator is not for use in mobile equipment or marine applications.

WHEN TRANSPORTING OR REPAIRING EQUIPMENT

Transport/repair with fuel tank EMPTY or with fuel shutoff valve OFF.

Disconnect spark plug wire.

WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK

Store away from furnaces, stoves, water heaters, clothes dryers or other appliances that have pilot light or other ignition source because they can ignite fuel vapors.

WARNING

This generator does not meet U. S. Coast Guard Regulation 33CFR-183 and should not be used on marine applications.

Failure to use the appropriate U. S. Coast Guard approved generator could result in death or serious injury and/or property damage.

3

3

Image 3
Contents Model / Modelo 030220 7000W Table of Contents Safety RulesEquipment Description When Transporting or Repairing Equipment When Adding or Draining FuelWhen Starting Equipment When Operating EquipmentWhen Testing for Engine Spark When Adjusting or Making Repairs to Your GeneratorFuel Tank Capacity of seven 7 U.S. gallons Know Your GeneratorUnpacking the Generator AssemblyInstall Wheel Kit Refer to and install the wheel kit as followsAdd Fuel When Adding FuelBefore Starting the Engine Add Engine OilGenerator Location Using the GeneratorConnecting to a Building’s Electrical System System GroundDo not Overload the GENERATOR. See Don’t Overload Generator Connecting Electrical LoadsOperating Generator Starting the Engine120/240 Volt AC, 30 Amp, Locking Receptacle ReceptaclesCold Weather Operation Stopping the EngineCreating a Permanent Shelter Creating a Temporary ShelterExample Power ManagementDON’T Overload Generator CapacityEngine Maintenance SpecificationsGeneral Maintenance Recommendations Generator CleaningOther Storage Tips StorageGenerator Storage Engine StorageProblem Cause Correction TroubleshootingPowerBOSS Limited Warranty Advertencia Tabla DE ContenidosDescripción DEL Equipo Reglas DE SeguridadCuando Transporte O Repare EL Equipo Cuando Añada Combustible O Vacíe EL DepósitoCuando Ponga EN Funcionamiento EL Equipo Cuando Opere EL EquipoPrecaución Cuando Ajuste O Haga Reparaciones a SU GeneradorCuando Pruebe LA Bujía DEL Motor Tapa del Depósito del Aceite Llene el motor con aceite aquí Conozca SU GeneradorInstale el Juego de Ruedas Como Sigue Figura MontajeDesembalaje del Generador Instale el Juego de RuedasCuando Añada Combustible Antes DE Darle Arranque AL MotorAgregar Aceite al Motor Agregue CombustibleConexión al Sistema Eléctrico de un Edificio USO DEL GeneradorTierra del Sistema Ubicación del GeneradorNo Sobrecargue GENERADOR. Vea No Sobrecargue Generador Operando EL GeneradorEncienda el Motor Conexion De Cargas ElectricasVolt AC, 20 Amperios, Receptáculos Dobles Receptáculos PrecauciónOperación Durante UN Clima Frío Parado Del MotorCreación de una Estructura de Protección Permanente Creación de una Estructura de Protección ProvisionalEjemplo No Sobrecargue GeneradorCapacidad Control de la EnergíaMantenimiento del Generador EspecificacionesRecomendaciones Generales DE Mantenimiento Mantenimiento del MotorOtras Sugerencias Para el Almacenando AlmacenamientoAlmacenando el Generador Almacenando el MotorDiagnositicos DE Averías Uso comercial Uso del consumidor

30220 specifications

The Briggs & Stratton 30220 is a powerful and versatile portable generator that has gained popularity among both residential and commercial users. Engineered for reliable performance, this generator is equipped with a range of features and technologies that make it an ideal choice for emergency backup power, recreational activities, and job site use.

One of the standout features of the Briggs & Stratton 30220 is its robust engine. Powered by a 306cc OHV (overhead valve) engine, it delivers a maximum output of 7,000 watts and a running wattage of 5,500 watts. This combination provides ample power for essential household appliances during power outages, as well as tools and equipment for construction or outdoor projects.

The 30220 model incorporates a durable steel frame, ensuring long-lasting durability and stability. Its design includes a user-friendly control panel for easy access to multiple power outlets, including four 120V household outlets and a 120V/240V twist-lock outlet. This versatility allows users to power everything from small appliances to larger equipment effortlessly.

One notable technological advancement in the Briggs & Stratton 30220 is the inclusion of EZ Start technology. This innovative feature simplifies the starting process, allowing users to start the generator smoothly with less effort. Additionally, the generator is equipped with a low-oil shutdown system that automatically turns off the engine to prevent damage, enhancing both safety and reliability.

Another key characteristic of the Briggs & Stratton 30220 is its fuel efficiency. The generator runs on gasoline, and with a 4-gallon fuel tank, it can provide up to 10 hours of continuous operation at a 50% load. This extended runtime makes it suitable for prolonged usage, such as during severe weather events.

Additionally, the generator is designed with mobility in mind. It features heavy-duty wheels and a fold-down handle for easy transportation, making it convenient to move wherever power is needed.

Overall, the Briggs & Stratton 30220 combines robust power, advanced technology, and user-friendly features, making it an exceptional choice for those in need of dependable and efficient portable power solutions. Whether for home use or outdoor adventures, this generator is built to deliver reliability and performance when it matters most.