BEFORE STARTING THE ENGINE

Add Engine Oil

Place generator on a level surface.

Refer to engine operator’s manual and follow oil recommendations and instructions.

CAUTION

Any attempt to crank or start the engine before it has been properly filled with the recommended oil will result in equipment failure.

Refer to engine operator’s manual for oil fill information.

Damage to equipment resulting from failure to follow this instruction will void warranty.

NOTE: Check oil often during engine break–in. Refer to engine owner’s manual for recommendations.

NOTE: The alternator assembly rotates on a prelubricated and sealed ball bearing that requires no additional lubrication for the life of the bearing.

Add Fuel

Fuel must meet these requirements:

Clean, fresh, unleaded gasoline.

A minimum of 87 octane/87 AKI (91 RON). High altitude use, see below.

Gasoline with up to 10% ethanol (gasohol) or up to 15% MTBE (methyl tertiary butyl ether) is acceptable.

CAUTION

Avoid generator damage.

Failure to follow Operator’s Manual for fuel reccomendations voids warranty.

DO NOT use unapproved gasoline such as E85.

DO NOT mix oil in fuel.

DO NOT modify engine to run on alternate fuels.

To protect the fuel system from gum formation, mix in a fuel stabilizer when adding fuel. See Storage. All fuel is not the same. If you experience starting or performance problems after using fuel, switch to a different fuel provider or change brands. This engine is certified to operate on gasoline. The emission control system for this engine is EM (Engine Modifications).

WARNING

Fuel and its vapors are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

WHEN ADDING FUEL

Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

Fill fuel tank outdoors.

DO NOT overfill tank. Allow space for fuel expansion.

If fuel spills, wait until it evaporates before starting engine.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

DO NOT light a cigarette or smoke.

1.Clean area around fuel fill cap, remove cap.

2.Slowly add regular unleaded fuel to fuel tank. Be careful not to overfill. Allow about 1.5" of tank space for fuel expansion (Figure 3).

Figure 3 - Fuel Expansion

AirSpace

Tank

Fuel

1.5”

 

3.Install fuel cap and let any spilled fuel evaporate before starting engine.

High Altitude

At higher altitudes (over 5,000 feet), 85 octane/85 AKI (89 RON) gasoline is recommended. High-altitude use may require a carburetor jet kit to improve performance and decrease fuel consumption. See an Authorized Briggs & Stratton Dealer for more information.

9

Image 9
Contents Call Generator Helpline Llame Línea Directa del Generador Operator’s Manual Manual del OperarioTable of Contents Safety RulesEquipment Description When Starting Equipment When Adding or Draining FuelWhen Operating Equipment When Transporting or Repairing EquipmentPage When Testing for Engine Spark When Adjusting or Making Repairs to Your GeneratorKnow Your Generator Carton Contents AssemblyCheck Battery / Attach Negative Battery Wire Remove Generator From CartonRefer to and install the wheel kit as follows Install Wheel KitAdd Engine Oil Before Starting the EngineAdd Fuel Fuel must meet these requirementsConnecting to a Building’s Electrical System Using the GeneratorSystem Ground Generator LocationConnecting Electrical Loads Operating GeneratorStarting the Engine Receptacles Battery ChargerStopping the Engine Volt AC, 20 Amp, Duplex ReceptacleDont Overload Generator Power ManagementCapacity ExampleGeneral Maintenance Recommendations SpecificationsGenerator Storage StorageEngine Storage Other Storage TipsProblem Cause Correction TroubleshootingLimited Warranty Warranty PeriodDescripción DEL Equipo Tabla DE ContenidosReglas DE Seguridad AdvertenciaCuando Ponga EN Funcionamiento EL Equipo Cuando Añada Combustible O Vacíe EL DepósitoCuando Opere EL Equipo Cuando Transporte O Repare EL EquipoPrecaución Cuando Ajuste O Haga Reparaciones a SU GeneradorCuando Pruebe LA Bujía DEL Motor Conozca SU Generador Arranque Eléctrico MontajePara Retirar el Generador de la Caja Contenido De La CajaLas anillas en e pueden provocar lesiones oculares Instale el Juego de RuedasMotor Antes DE Darle Arranque ALAgregar Aceite al Motor Agregue CombustibleTierra del Sistema USO DEL GeneradorUbicación del Generador Conexión al Sistema Eléctrico de un EdificioEncienda el Motor Operando EL GeneradorConexion De Cargas Electricas No Sobrecargue EL GENERADOR. Vea No Sobrecargue GeneradorCargador DE Batería Receptáculos PrecauciónParado Del Motor Volt AC, 20 Amp, Receptáculo DoblesCapacidad No Sobrecargue GeneradorControl de la Energía EjemploMantenimiento del Motor EspecificacionesMantenimiento del Generador Mantenimiento de la BateríaAlmacenando el Generador AlmacenamientoAlmacenando el Motor Otras Sugerencias Para el AlmacenandoDiagnositicos DE Averías Problemo Accion CausaGarantía Limitada Período DE Garantía

030242 specifications

The Briggs & Stratton 030242 is a powerful and reliable portable generator that caters to a wide range of power needs. Renowned for its performance and durability, this generator is an ideal choice for homeowners seeking backup power solutions during outages, as well as for outdoor enthusiasts who require dependable energy sources for camping or recreational activities.

One of the standout features of the Briggs & Stratton 030242 is its impressive power output. It boasts a starting wattage of 3,000 watts and a running wattage of 2,500 watts, making it capable of supporting essential household appliances like refrigerators, lights, and sump pumps. This makes it particularly useful during power outages or in emergency situations. The generator is powered by a reliable 206cc OHV engine, designed for easy starting and efficient fuel consumption, allowing users to maximize their usage time before refueling is necessary.

The 030242 integrates advanced technology, including a low-oil shutdown feature that protects the engine from damage by automatically turning off the generator when oil levels are low. This assures users that they can operate the generator without the constant worry of monitoring oil levels. The generator is also equipped with a built-in surge protector, which helps safeguard connected devices from power spikes, ensuring they remain safe and functional.

Portability is another key characteristic of the Briggs & Stratton 030242. It features a lightweight design and includes convenient fold-down handles, allowing for easy mobility. With sturdy wheels, it can be effortlessly transported to various locations, whether it’s in the backyard or out in the field.

The generator features multiple outlets, including two 120V household outlets and one 12V DC outlet for charging batteries, expanding its versatility in powering various tools and devices. Additionally, the noise level is kept to a minimum, producing only 59 dB at 25% load, which is quieter than many traditional generators, making it more pleasant for users and their neighbors.

In summary, the Briggs & Stratton 030242 is a versatile and efficient generator that combines power, portability, and advanced safety features, making it an excellent investment for anyone in need of reliable energy solutions.