Briggs & Stratton 030242 manual When Adjusting or Making Repairs to Your Generator

Page 5

6200W Portable Generator

WARNING

Unintentional sparking can result in fire or electric shock.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR

Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK

Use approved spark plug tester.

DO NOT check for spark with spark plug removed.

CAUTION

Excessively high operating speeds increase risk of injury and damage to generator.

Excessively low speeds impose a heavy load.

DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed speed.

DO NOT modify generator in any way.

CAUTION

Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

See “Don’t Overload Generator”.

Start generator and let engine stabilize before connecting electrical loads.

Connect electrical loads in OFF position, then turn ON for operation.

Turn electrical loads OFF and disconnect from generator before stopping generator.

CAUTION

Improper treatment of generator can damage it and shorten its life.

Use generator only for intended uses.

If you have questions about intended use, ask dealer or call 1-800-743-4115.

Operate generator only on level surfaces.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

If connected devices overheat, turn them off and disconnect them from generator.

Shut off generator if:

-electrical output is lost;

-equipment sparks, smokes, or emits flames; -unit vibrates excessively.

5

Image 5
Contents Call Generator Helpline Llame Línea Directa del Generador Operator’s Manual Manual del Operario Equipment Description Table of Contents Safety Rules When Starting Equipment When Adding or Draining FuelWhen Operating Equipment When Transporting or Repairing EquipmentPage When Testing for Engine Spark When Adjusting or Making Repairs to Your GeneratorKnow Your Generator Carton Contents AssemblyCheck Battery / Attach Negative Battery Wire Remove Generator From CartonRefer to and install the wheel kit as follows Install Wheel KitAdd Engine Oil Before Starting the EngineAdd Fuel Fuel must meet these requirementsConnecting to a Building’s Electrical System Using the GeneratorSystem Ground Generator LocationStarting the Engine Connecting Electrical LoadsOperating Generator Receptacles Battery ChargerStopping the Engine Volt AC, 20 Amp, Duplex ReceptacleDont Overload Generator Power ManagementCapacity ExampleGeneral Maintenance Recommendations SpecificationsGenerator Storage StorageEngine Storage Other Storage TipsProblem Cause Correction TroubleshootingLimited Warranty Warranty PeriodDescripción DEL Equipo Tabla DE ContenidosReglas DE Seguridad AdvertenciaCuando Ponga EN Funcionamiento EL Equipo Cuando Añada Combustible O Vacíe EL DepósitoCuando Opere EL Equipo Cuando Transporte O Repare EL EquipoCuando Pruebe LA Bujía DEL Motor PrecauciónCuando Ajuste O Haga Reparaciones a SU Generador Conozca SU Generador Arranque Eléctrico MontajePara Retirar el Generador de la Caja Contenido De La CajaLas anillas en e pueden provocar lesiones oculares Instale el Juego de RuedasMotor Antes DE Darle Arranque ALAgregar Aceite al Motor Agregue CombustibleTierra del Sistema USO DEL GeneradorUbicación del Generador Conexión al Sistema Eléctrico de un EdificioEncienda el Motor Operando EL GeneradorConexion De Cargas Electricas No Sobrecargue EL GENERADOR. Vea No Sobrecargue GeneradorCargador DE Batería Receptáculos PrecauciónParado Del Motor Volt AC, 20 Amp, Receptáculo DoblesCapacidad No Sobrecargue GeneradorControl de la Energía EjemploMantenimiento del Motor EspecificacionesMantenimiento del Generador Mantenimiento de la BateríaAlmacenando el Generador AlmacenamientoAlmacenando el Motor Otras Sugerencias Para el AlmacenandoDiagnositicos DE Averías Problemo Accion CausaGarantía Limitada Período DE Garantía