Briggs & Stratton 030209-1 Assembly, Unpacking the Generator, Carton Contents, Install Wheel Kit

Page 6

5500W Portable Generator

ASSEMBLY

Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended oil and fuel.

Engine operator’s manual

Wheel kit

If any parts are missing or damaged, call the generator helpline at 1-800-743-4115.

If you have any problems with the assembly of your generator, please call the generator helpline at

1-800-743-4115. If calling for assistance, please have the model, revision, and serial number from the data tag available. See “Know Your Generator” for data tag location.

Unpacking the Generator

1.Set the carton on a rigid flat surface.

2.Remove everything from carton except generator.

3.Open carton completely by cutting each corner from top to bottom.

4.Leave generator on carton to install wheel kit.

Carton Contents

Check all contents against those listed below:

Main unit

Engine oil

Operator’s manual

Install Wheel Kit

The wheel kit is designed to greatly improve the portability of your generator.

NOTE: Wheel kit is not intended for over-the-road use.

You will need the following tools to install this wheel kit:

1/2" or 13mm socket wrench

1/2" or 13mm open end wrench

Pliers

Safety glasses

Refer to Figure 1 and install the wheel kit as follows:

1.Tip generator so that engine end is up.

2.Slide axle through both mounting brackets.

3.Slide a wheel over the axle.

4.Place a washer on axle and then place an e-ring in axle groove.

5.Install e-ring with pliers, squeezing from top of e-ring to bottom of axle.

Figure 1 — Install Wheel Kit

Capscrew

 

 

Nut

 

 

Handle

 

Wheel

 

 

 

 

Washer

 

Axle

 

Mounting Leg

Capscrew

 

 

E-Ring

 

 

 

Nut

 

 

6

 

Image 6
Contents 030209-1 5500W Table of Contents Safety RulesEquipment Description When Operating Equipment When Adding or Draining FuelWhen Starting Equipment When Transporting or Repairing EquipmentWhen Adjusting or Making Repairs to Your Generator When Testing for Engine SparkKnow Your Generator Install Wheel Kit AssemblyCarton Contents Refer to and install the wheel kit as followsAdd Engine Oil When Adding FuelBefore Starting the Engine Add FuelSystem Ground Using the GeneratorConnecting to a Building’s Electrical System Generator LocationStarting the Engine Connecting Electrical LoadsOperating Generator Do not Overload the GENERATOR. See Don’t Overload Generator120/240 Volt AC, 30 Amp, Locking Receptacle ReceptaclesStopping the Engine Volt AC, 20 Amp, Duplex ReceptaclesCapacity Power ManagementDont Overload Generator ExampleEngine Maintenance SpecificationsGeneral Maintenance Recommendations Generator MaintenanceEngine Storage StorageGenerator Storage Other Storage TipsTroubleshooting Problem Cause CorrectionLimited Warranty Reglas DE Seguridad Tabla DE ContenidosDescripción DEL Equipo AdvertenciaCuando Opere EL Equipo Cuando Añada Combustible O Vacíe EL DepósitoCuando Ponga EN Funcionamiento EL Equipo Cuando Transporte O Repare EL EquipoPrecaución Cuando Ajuste O Haga Reparaciones a SU GeneradorCuando Pruebe LA Bujía DEL Motor Conozca SU Generador Tapa del Depósito del Aceite Llene el motor con aceiteInstale el Juego de Ruedas MontajeDesembalaje del Generador Contenido de la CajaAgregar Aceite al Motor Antes DE Darle Arranque AL MotorAgregue Combustible Cuando Añada CombustibleConexión al Sistema Eléctrico de un Edificio USO DEL GeneradorTierra del Sistema Ubicación del GeneradorConexion De Cargas Electricas Operando EL GeneradorEncienda el Motor No Sobrecargue EL GENERADOR.Vea No Sobrecargue Generador120/240 Voltios AC, 30 Amp, Receptáculo de Seguridad Receptáculos PrecauciónParado Del Motor Volt AC, 20 Amp, Receptáculos DoblesControl de la Energía No Sobrecargue GeneradorCapacidad EjemploMantenimiento del Motor EspecificacionesRecomendaciones Generales DE Mantenimiento Para Limpiar el GeneradorAlmacenando el Generador Diagnositicos DE AveríasAlmacenamiento Almacenando el MotorGarantía Limitada