Briggs & Stratton 030209-1 Using the Generator, System Ground, Generator Location

Page 8

5500W Portable Generator

USING THE GENERATOR

System Ground

The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles.The system ground is connected to the AC neutral wire (the neutral is bonded to the generator frame).

Special Requirements

There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction.

In some areas, generators are required to be registered with local utility companies.

Generator Location

Generator Clearance

WARNING

Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire.

Keep at least 5 ft. (152 cm) clearance on all sides of generator including overhead.

Place generator in a well ventilated area, which will allow for removal of deadly exhaust gas. DO NOT place generator where exhaust gas could accumulate and enter inside or be drawn into a potentially occupied building. Ensure exhaust gas is kept away from any windows, doors, ventilation intakes or other openings that can allow exhaust gas to collect in a confined area (Figure 3). Prevailing winds and air currents should be taken into consideration when positioning generator.

If the generator is used at a construction site, there may be additional regulations which must be observed.

Connecting to a Building’s Electrical System

Connections for standby power to a building’s electrical system must be made by a qualified electrician.The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes.

WARNING

Generator produces powerful voltage.

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.

Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.

DO NOT touch bare wires or receptacles.

DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

DO NOT operate generator in the rain.

DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

DO NOT allow unqualified persons or children to operate or service generator.

WARNING

Running generator gives off carbon monoxide, an odorless, colorless, poison gas.

Breathing carbon monoxide can cause nausea, fainting or death.

Operate generator ONLY outdoors.

Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings.

DO NOT operate generator inside any building or enclosure (even if doors or windows are open), including the generator compartment of a recreational vehicle (RV).

Figure 3 — Generator Clearance

Typical Generator Shown

Exhaust Port

8

Image 8
Contents 030209-1 5500W Equipment Description Table of ContentsSafety Rules When Adding or Draining Fuel When Starting EquipmentWhen Operating Equipment When Transporting or Repairing EquipmentWhen Adjusting or Making Repairs to Your Generator When Testing for Engine SparkKnow Your Generator Assembly Carton ContentsInstall Wheel Kit Refer to and install the wheel kit as followsWhen Adding Fuel Before Starting the EngineAdd Engine Oil Add FuelUsing the Generator Connecting to a Building’s Electrical SystemSystem Ground Generator LocationConnecting Electrical Loads Operating GeneratorStarting the Engine Do not Overload the GENERATOR. See Don’t Overload GeneratorReceptacles Stopping the Engine120/240 Volt AC, 30 Amp, Locking Receptacle Volt AC, 20 Amp, Duplex ReceptaclesPower Management Dont Overload GeneratorCapacity ExampleSpecifications General Maintenance RecommendationsEngine Maintenance Generator MaintenanceStorage Generator StorageEngine Storage Other Storage TipsTroubleshooting Problem Cause CorrectionLimited Warranty Tabla DE Contenidos Descripción DEL EquipoReglas DE Seguridad AdvertenciaCuando Añada Combustible O Vacíe EL Depósito Cuando Ponga EN Funcionamiento EL EquipoCuando Opere EL Equipo Cuando Transporte O Repare EL EquipoCuando Pruebe LA Bujía DEL Motor PrecauciónCuando Ajuste O Haga Reparaciones a SU Generador Conozca SU Generador Tapa del Depósito del Aceite Llene el motor con aceiteMontaje Desembalaje del GeneradorInstale el Juego de Ruedas Contenido de la CajaAntes DE Darle Arranque AL Motor Agregue CombustibleAgregar Aceite al Motor Cuando Añada CombustibleUSO DEL Generador Tierra del SistemaConexión al Sistema Eléctrico de un Edificio Ubicación del GeneradorOperando EL Generador Encienda el MotorConexion De Cargas Electricas No Sobrecargue EL GENERADOR.Vea No Sobrecargue GeneradorReceptáculos Precaución Parado Del Motor120/240 Voltios AC, 30 Amp, Receptáculo de Seguridad Volt AC, 20 Amp, Receptáculos DoblesNo Sobrecargue Generador CapacidadControl de la Energía EjemploEspecificaciones Recomendaciones Generales DE MantenimientoMantenimiento del Motor Para Limpiar el GeneradorDiagnositicos DE Averías AlmacenamientoAlmacenando el Generador Almacenando el MotorGarantía Limitada