STORAGE

The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than

30 days, use the following guidelines to prepare it for storage.

Generator Storage

Clean the generator as outlined in “Generator Cleaning”.

Check that cooling air slots and openings on generator are open and unobstructed.

WARNING

Storage covers can be flammable.

DO NOT place a storage cover over a hot generator.

Let equipment cool for a sufficient time before placing the cover on the equipment.

Engine Storage

See engine operator’s manual for instructions.

Other Storage Tips

Always store unit with fuel shut off valve in the “Off” position (Figure 6, earlier).

To prevent gum from forming in fuel system or on essential carburetor parts, empty entire contents of both supplied fuel stabilizer containers into fuel tank and fill with fresh fuel. Run the unit for several minutes to circulate the additive through the carburetor.The unit and fuel can then be stored for up to 6 months. Additional fuel stabilizer can be purchased locally.

DANGER

Contents are harmful or fatal if swallowed. Avoid contact to eyes, skin or clothing. DO NOT take internally. Avoid breathing the mist or vapor. Overexposure to eyes or skin can cause irritation. Keep stabilizer out of the reach of children.

Fuel stabilizer is a hazardous chemical.**

If SWALLOWED, call physician immediately.

In case of emergency, contact a physician immediately and call 1-800-424-9300 for material safety information.

**Fuel stabilizer contains: 2,6-di-tret-butylphenol (128-39-2) and aliphatic petroleum distillate (64742-47-8).

Fuel tank may swell in storage if vent is closed.When storing generator with fuel in the tank, make sure the vent knob is turned fully counter-clockwise.

Store unit in clean and dry area.

13

Image 13
Contents 01655-3 Safety Rules Table of ContentsEquipment Description When Starting Equipment When Adding or Draining FuelWhen Operating Equipment When Transporting or Repairing EquipmentWhen Testing for Engine Spark When Adjusting or Making Repairs to Your GeneratorRecoil Starter Know Your GeneratorDouble Pole Circuit Carton Contents AssemblyUnpacking the Generator Attach Handle to UnitBefore Starting the Engine When Adding FuelAdd Engine Oil Add FuelConnecting to a Building’s Electrical System Using the GeneratorSystem Ground Generator LocationOperating Generator Connecting Electrical LoadsStarting the Engine Do not Overload the GENERATOR. See Don’t Overload GeneratorStopping the Engine ReceptaclesVolt AC, 20 Amp, Duplex Receptacle 120/240 Volt AC, 30 Amp, Locking ReceptacleDont Overload Generator Power ManagementCapacity ExampleGeneral Maintenance Recommendations SpecificationsEngine Maintenance Generator MaintenanceGenerator Storage StorageEngine Storage Other Storage TipsProblem Cause Solution TroubleshootingLimited Warranty Table DES Matières Symboles de Danger et MoyensDescription DE L Équipement Règles DE SécuritéLors DU Démarrage DE Léquipement Lors DE Lajout OU DE LA Vidange DU CarburantLorsque Léquipement Fonctionne Lorsque Vous Transportez OU Réparez LéquipementLors DE Tests Dallumage DU Moteur Lorsque Vous Réglez OU Réparez Votre GénérateurBouchon/repère de remplissage dhuile Ajoutez de lhuile Connaissez Votre GénérateurPrises de courant double de 120 Volts c.a., 20 Ampères Enlever le générateur de la boite AssemblageFixez la Poignée à lAppareil Principal Les Contenus De BoîteAjoutez de lhuile à moteur Avant LE Démarrage DU MoteurAjoutez de lessence Lors DE Lajout DU CarburantGénératrice Utilisation DE LADémarrage du Moteur Utilisation DU GénérateurBranchement des Charges Électriques Arrêt du Moteur Prises DE CourantVolts c.a., 20 Ampères Prise de Courant Double Prise à Verrouillage de 120/240 Volts c.a., 30 AmpèresCapacité NE Surchargez PAS GénérateurGestion de la Consommation ExempleSpécifications Recommandations Générales D’ENTRETIENRemisage Remisage du Moteur DépannageAutres Idées de Remisage Garantie Limitée Période DE Garantie

01655-3 specifications

The Briggs & Stratton 01655-3 is an advanced portable generator renowned for its reliability and high-performance output. With its robust engineering, this generator is designed to meet the power needs of both residential and commercial applications, making it a versatile choice for users seeking a dependable source of electricity.

One of the main features of the Briggs & Stratton 01655-3 is its impressive power output. It typically offers a starting wattage of around 7,500 and a running wattage of about 6,000, which enables it to handle multiple appliances simultaneously, from refrigerators and air conditioners to power tools and lighting. This capability is particularly beneficial during power outages or when users require additional power for outdoor events.

The generator is powered by a reliable Briggs & Stratton engine, which is known for its durability and longevity. The engine is equipped with advanced technologies such as a low-oil shutdown feature, which automatically turns off the engine when oil levels are too low, preventing potential engine damage. Additionally, the generator is engineered for fuel efficiency, allowing users to run it for extended periods without frequent refueling.

Another standout characteristic of the Briggs & Stratton 01655-3 is its portability. The generator comes with sturdy wheels and a comfortable handle, making it easy to transport from one location to another. This feature is particularly useful for contractors or homeowners who require temporary power solutions in different areas.

The generator is also designed with user-friendly controls, featuring a power panel that provides clear access to multiple outlets, including standard 120V household outlets and a 120/240V twist-lock outlet for heavier equipment. This versatility allows users to connect various devices and tools with ease.

Safety is another priority with the Briggs & Stratton 01655-3. The generator is designed with robust protective features, including circuit breakers, which help prevent overloads and ensure the safety of connected devices. Additionally, it operates quietly, reducing noise pollution in residential settings.

With its combination of power, efficiency, and portability, the Briggs & Stratton 01655-3 is an excellent choice for those seeking a reliable generator. Whether for emergency backup power, recreational use, or construction projects, this generator stands out as a trustworthy solution to meet diverse power needs.