Briggs & Stratton 01655-3 manuel dutilisation When Adjusting or Making Repairs to Your Generator

Page 4

SAFETY RULES

WARNING

Generator produces powerful voltage.

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.

Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.

DO NOT touch bare wires or receptacles.

DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

DO NOT operate generator in the rain or wet weather.

DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

DO NOT allow unqualified persons or children to operate or service generator.

WARNING

Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C).

Severe burns can occur on contact.

Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire.

DO NOT touch hot surfaces and avoid hot exhaust gases.

Allow equipment to cool before touching.

Keep at least 5 ft. (152 cm) clearance on all sides of generator including overhead.

Code of Federal Regulation (CFR) Title 36 Parks, Forests, and Public Property require equipment powered by an internal combustion engine to have a spark arrester, maintained in effective working order, complying to USDA Forest service standard 5100-1C or later revision. In the State of California a spark arrester is required under section 4442 of the California Public resources code. Other states may have similar laws.

WARNING

Unintentional sparking can result in fire or electric shock.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR

Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK

Use approved spark plug tester.

DO NOT check for spark with spark plug removed.

WARNING

Rapid retraction of starter cord (kickback) will pull hand and arm toward engine faster than you can let go.

Broken bones, fractures, bruises or sprains could result.

When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.

NEVER start or stop engine with electrical devices plugged in and turned on.

CAUTION

Excessively high operating speeds increase risk of injury and damage to generator.

Excessively low speeds impose a heavy load.

DO NOT tamper with governed speed. Generator supplies correct rated frequency and voltage when running at governed speed.

DO NOT modify generator in any way.

CAUTION

Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.

See “Don’t Overload Generator”.

Start generator and let engine stabilize before connecting electrical loads.

Connect electrical loads in OFF position, then turn ON for operation.

Turn electrical loads OFF and disconnect from generator before stopping generator.

CAUTION

Improper treatment of generator can damage it and shorten its life.

Use generator only for intended uses.

If you have questions about intended use, ask dealer or call 1-800-743-4115.

Operate generator only on level surfaces.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

If connected devices overheat, turn them off and disconnect them from generator.

Shut off generator if:

-electrical output is lost;

-equipment sparks, smokes, or emits flames; -unit vibrates excessively.

4

Image 4
Contents 01655-3 Safety Rules Table of ContentsEquipment Description When Adding or Draining Fuel When Starting EquipmentWhen Operating Equipment When Transporting or Repairing EquipmentWhen Adjusting or Making Repairs to Your Generator When Testing for Engine SparkRecoil Starter Know Your GeneratorDouble Pole Circuit Assembly Carton ContentsUnpacking the Generator Attach Handle to UnitWhen Adding Fuel Before Starting the EngineAdd Engine Oil Add FuelUsing the Generator Connecting to a Building’s Electrical SystemSystem Ground Generator LocationConnecting Electrical Loads Operating GeneratorStarting the Engine Do not Overload the GENERATOR. See Don’t Overload GeneratorReceptacles Stopping the EngineVolt AC, 20 Amp, Duplex Receptacle 120/240 Volt AC, 30 Amp, Locking ReceptaclePower Management Dont Overload GeneratorCapacity ExampleSpecifications General Maintenance RecommendationsEngine Maintenance Generator MaintenanceStorage Generator StorageEngine Storage Other Storage TipsTroubleshooting Problem Cause SolutionLimited Warranty Symboles de Danger et Moyens Table DES MatièresDescription DE L Équipement Règles DE SécuritéLors DE Lajout OU DE LA Vidange DU Carburant Lors DU Démarrage DE LéquipementLorsque Léquipement Fonctionne Lorsque Vous Transportez OU Réparez LéquipementLorsque Vous Réglez OU Réparez Votre Générateur Lors DE Tests Dallumage DU MoteurBouchon/repère de remplissage dhuile Ajoutez de lhuile Connaissez Votre GénérateurPrises de courant double de 120 Volts c.a., 20 Ampères Assemblage Enlever le générateur de la boiteFixez la Poignée à lAppareil Principal Les Contenus De BoîteAvant LE Démarrage DU Moteur Ajoutez de lhuile à moteurAjoutez de lessence Lors DE Lajout DU CarburantUtilisation DE LA GénératriceDémarrage du Moteur Utilisation DU GénérateurBranchement des Charges Électriques Prises DE Courant Arrêt du MoteurVolts c.a., 20 Ampères Prise de Courant Double Prise à Verrouillage de 120/240 Volts c.a., 30 AmpèresNE Surchargez PAS Générateur CapacitéGestion de la Consommation ExempleSpécifications Recommandations Générales D’ENTRETIENRemisage Remisage du Moteur DépannageAutres Idées de Remisage Période DE Garantie Garantie Limitée

01655-3 specifications

The Briggs & Stratton 01655-3 is an advanced portable generator renowned for its reliability and high-performance output. With its robust engineering, this generator is designed to meet the power needs of both residential and commercial applications, making it a versatile choice for users seeking a dependable source of electricity.

One of the main features of the Briggs & Stratton 01655-3 is its impressive power output. It typically offers a starting wattage of around 7,500 and a running wattage of about 6,000, which enables it to handle multiple appliances simultaneously, from refrigerators and air conditioners to power tools and lighting. This capability is particularly beneficial during power outages or when users require additional power for outdoor events.

The generator is powered by a reliable Briggs & Stratton engine, which is known for its durability and longevity. The engine is equipped with advanced technologies such as a low-oil shutdown feature, which automatically turns off the engine when oil levels are too low, preventing potential engine damage. Additionally, the generator is engineered for fuel efficiency, allowing users to run it for extended periods without frequent refueling.

Another standout characteristic of the Briggs & Stratton 01655-3 is its portability. The generator comes with sturdy wheels and a comfortable handle, making it easy to transport from one location to another. This feature is particularly useful for contractors or homeowners who require temporary power solutions in different areas.

The generator is also designed with user-friendly controls, featuring a power panel that provides clear access to multiple outlets, including standard 120V household outlets and a 120/240V twist-lock outlet for heavier equipment. This versatility allows users to connect various devices and tools with ease.

Safety is another priority with the Briggs & Stratton 01655-3. The generator is designed with robust protective features, including circuit breakers, which help prevent overloads and ensure the safety of connected devices. Additionally, it operates quietly, reducing noise pollution in residential settings.

With its combination of power, efficiency, and portability, the Briggs & Stratton 01655-3 is an excellent choice for those seeking a reliable generator. Whether for emergency backup power, recreational use, or construction projects, this generator stands out as a trustworthy solution to meet diverse power needs.