Briggs & Stratton 01655-3 manuel dutilisation Troubleshooting, Problem Cause Solution

Page 14

TROUBLESHOOTING

TROUBLESHOOTING

Problem

Cause

Solution

 

1.

Circuit breaker is open.

1.

Reset circuit breaker.

 

2.

Poor connection or defective cord

2.

Check and repair.

Generator is running, but no AC

 

set.

 

 

output is available.

3.

Connected device is bad.

3.

Connect another device that is in

 

 

 

 

good condition.

 

4.

Fault in generator.

4.

Contact authorized service facility.

 

 

 

 

 

Generator runs good but bogs

1.

Short circuit in a connected load.

1.

Disconnect shorted electrical load.

2.

Generator is overloaded.

2.

See "Don't Overload Generator".

down when loads are connected.

3.

Shorted generator circuit.

3.

Contact authorized service facility.

 

 

 

 

 

 

 

1.

Fuel valve is in the "Off" position.

1.

Turn fuel valve to the "On"

Generator will not start; or starts

 

 

 

position.

2.

Vent knob in fuel gauge is closed.

2.

Open vent knob in fuel gauge.

and runs rough.

3.

Low oil level.

3.

Fill crankcase to proper level or

 

 

 

 

 

place generator on level surface.

 

 

 

 

 

Generator shuts down during

1.

Out of fuel.

1.

Fill fuel tank.

2.

Low oil level.

2.

Fill crankcase to proper level or

operation.

 

 

 

place generator on level surface.

 

 

 

 

 

 

 

Generator lacks power.

Load is too high.

See "Don't Overload Generator".

 

 

 

 

 

14

Image 14
Contents 01655-3 Equipment Description Table of ContentsSafety Rules When Operating Equipment When Adding or Draining FuelWhen Starting Equipment When Transporting or Repairing EquipmentWhen Adjusting or Making Repairs to Your Generator When Testing for Engine SparkDouble Pole Circuit Know Your GeneratorRecoil Starter Unpacking the Generator AssemblyCarton Contents Attach Handle to UnitAdd Engine Oil When Adding FuelBefore Starting the Engine Add FuelSystem Ground Using the GeneratorConnecting to a Building’s Electrical System Generator LocationStarting the Engine Connecting Electrical LoadsOperating Generator Do not Overload the GENERATOR. See Don’t Overload GeneratorVolt AC, 20 Amp, Duplex Receptacle ReceptaclesStopping the Engine 120/240 Volt AC, 30 Amp, Locking ReceptacleCapacity Power ManagementDont Overload Generator ExampleEngine Maintenance SpecificationsGeneral Maintenance Recommendations Generator MaintenanceEngine Storage StorageGenerator Storage Other Storage TipsTroubleshooting Problem Cause SolutionLimited Warranty Description DE L Équipement Symboles de Danger et MoyensTable DES Matières Règles DE SécuritéLorsque Léquipement Fonctionne Lors DE Lajout OU DE LA Vidange DU CarburantLors DU Démarrage DE Léquipement Lorsque Vous Transportez OU Réparez LéquipementLorsque Vous Réglez OU Réparez Votre Générateur Lors DE Tests Dallumage DU MoteurPrises de courant double de 120 Volts c.a., 20 Ampères Connaissez Votre GénérateurBouchon/repère de remplissage dhuile Ajoutez de lhuile Fixez la Poignée à lAppareil Principal AssemblageEnlever le générateur de la boite Les Contenus De BoîteAjoutez de lessence Avant LE Démarrage DU MoteurAjoutez de lhuile à moteur Lors DE Lajout DU CarburantUtilisation DE LA GénératriceBranchement des Charges Électriques Utilisation DU GénérateurDémarrage du Moteur Volts c.a., 20 Ampères Prise de Courant Double Prises DE CourantArrêt du Moteur Prise à Verrouillage de 120/240 Volts c.a., 30 AmpèresGestion de la Consommation NE Surchargez PAS GénérateurCapacité ExempleRemisage Recommandations Générales D’ENTRETIENSpécifications Autres Idées de Remisage DépannageRemisage du Moteur Période DE Garantie Garantie Limitée

01655-3 specifications

The Briggs & Stratton 01655-3 is an advanced portable generator renowned for its reliability and high-performance output. With its robust engineering, this generator is designed to meet the power needs of both residential and commercial applications, making it a versatile choice for users seeking a dependable source of electricity.

One of the main features of the Briggs & Stratton 01655-3 is its impressive power output. It typically offers a starting wattage of around 7,500 and a running wattage of about 6,000, which enables it to handle multiple appliances simultaneously, from refrigerators and air conditioners to power tools and lighting. This capability is particularly beneficial during power outages or when users require additional power for outdoor events.

The generator is powered by a reliable Briggs & Stratton engine, which is known for its durability and longevity. The engine is equipped with advanced technologies such as a low-oil shutdown feature, which automatically turns off the engine when oil levels are too low, preventing potential engine damage. Additionally, the generator is engineered for fuel efficiency, allowing users to run it for extended periods without frequent refueling.

Another standout characteristic of the Briggs & Stratton 01655-3 is its portability. The generator comes with sturdy wheels and a comfortable handle, making it easy to transport from one location to another. This feature is particularly useful for contractors or homeowners who require temporary power solutions in different areas.

The generator is also designed with user-friendly controls, featuring a power panel that provides clear access to multiple outlets, including standard 120V household outlets and a 120/240V twist-lock outlet for heavier equipment. This versatility allows users to connect various devices and tools with ease.

Safety is another priority with the Briggs & Stratton 01655-3. The generator is designed with robust protective features, including circuit breakers, which help prevent overloads and ensure the safety of connected devices. Additionally, it operates quietly, reducing noise pollution in residential settings.

With its combination of power, efficiency, and portability, the Briggs & Stratton 01655-3 is an excellent choice for those seeking a reliable generator. Whether for emergency backup power, recreational use, or construction projects, this generator stands out as a trustworthy solution to meet diverse power needs.