Baldor MN2410 manual Appendix a Premier K Series, Figure A-1 K3000 Operator Panel

Page 23

Appendix A

Premier K Series

Information in this Appendix applies to the following Baldor Generators:

K3000, K5000, K5000E, K6500, K6500E

Caution: The brass connecting tab on some 120VAC duplex receptacles have been removed. Each receptacle is powered by a separate generator winding. When replacing a receptacle, inspect the brass tab that normally links both receptacles. If it is removed, be sure to remove the brass tab from the replacement receptacle before it is installed. Failure to remove the tab will cause a direct short to the generator windings and cause possible generator damage.

Operator Panel Configuration

Figure A-1 K3000 Operator Panel

120 VOLTS

 

 

DC

 

 

OUTPUT

120 VOLTS

 

 

AC VOLTMETER

DC POWER

CIRCUIT BREAKERS

ON

OFF

 

NEMA 5-15R GFCI Receptacle.

This ground fault circuit interrupter duplex receptacle is rated at 125VAC, 15 Amps. NEMA L5-30R Receptacle. Twist-lock style receptacle rated for 125VAC, 30 Amps.

DC Output.

12VDC output terminals for 12V loads.

AC Voltmeter.

This voltmeter displays the voltage level being produced by the generator set.

DC Power

Turns On/Off DC power at the DC Output terminals.

Hour Meter.

Displays the total run time hours of the generator set.

Circuit Breakers.

Provide overload protection for the generator set.

Figure A-2 K5000/K5000E/K6500/K6500E Operator Panel

NEMA 5-15R GFCI Receptacle.

This ground fault circuit interrupter duplex receptacle is rated at 125VAC, 15 Amps.

120 VOLTS 120/240 VOLTS

DC

OUTPUT

120 VOLTS

AC VOLTMETER

AUTO IDLER

CIRCUIT BREAKERS

NEMA L5-30R Receptacle. Twist-lock style receptacle rated for 125VAC, 30 Amps. NEMA L14-30R Receptacle. Twist-lock style receptacle rated for 125/250VAC, 30 Am

DC Output.

12VDC output terminals for 12V loads.

AC Voltmeter.

This voltmeter displays the voltage level being produced by the generator set.

Auto Idler Switch.

ON - Auto idler is active, engine RPM will reduce when load is removed. OFF - Engine runs at fixed speed (set by governor).

DC ON - Auto Idler is Off and DC output terminals have power for 12V loads.

ONDC

OFF

Hour Meter.

Displays the total run time hours of the generator set.

Circuit Breakers.

Provide overload protection for the generator set.

MN2410

Premier K Series A-1

Image 23
Contents Premier POW’R Products Generator California Proposition 65 Warning Table of Contents Appendix E Appendix CAppendix D Read This Manual Thoroughly Section Product Safety InformationOperation Precaution Statements Used In This ManualProperty Operation Warning Statements Burn Installation Maintenance Product Safety Information MN2410 Section General Information Limited WarrantyOwner’s Responsibilities Premier Generators Storage Section Receiving & InstallationPhysical Location Frame Ground Connection Receptacle ConnectionsEngine Oil Use of Electric Motor Loads Battery ConnectionsSeries K Recommended Engine Oil and Battery TypeAC Voltmeter Section OperationOperator Control Panel Elapsed TimeRecoil Start Start-Up Procedure Electric StartStopping Procedure Engine Section Troubleshooting and MaintenanceGeneral Service Problems and SolutionsTroubleshooting Guide Figure A-1 K3000 Operator Panel Appendix a Premier K SeriesTable A-1 Generator Set Parts List Replacement PartsControl Box Operator Panel Figure A-5 K3000 Wiring Diagram Figure A-6 K5000 Wiring Diagram Figure A-7 K5000E Wiring Diagram Figure A-8 K6500 Wiring Diagram Figure A-9 K6500E Wiring Diagram R30, R45, R45E, R60, R60E Appendix B Premier R SeriesFigure B-3 Alternator Assembly Bearing included with rotor Figure B-5 R30 Wiring Diagram Figure B-6 R45/45E Wiring Diagram Figure B-7 R60 Wiring Diagram Figure B-8 R60E Wiring Diagram Premier R Series MN2410 Figure C-1 OHV30 Operator Panel Appendix C Premier OHV SeriesTable C-1 Generator Set Parts List Figure C-4 Alternator AssemblyOHV30 Figure C-6 OHV30 Wiring Diagram Figure C-7 OHV40 / OHV50 / OHV60 Wiring Diagram Figure C-8 OHV60E Wiring Diagram Figure C-9 OHV 85E Wiring Diagram Premier OHV Series MN2410 Figure D-1 OHV100E Operator Panel Appendix D Premier OHV100E SeriesFigure D-2 Alternator Assembly Table D-1 Generator Set Parts List Figure D-4 OHV100E Wiring Diagram Figure D-5 OHV100E Generator Output Wiring Diagram Figure D-6 OHV100E DC Wiring Diagram Figure E-1 OHV110E Operator Panel Appendix E Premier OHV110E SeriesFigure E-2 Alternator Assembly Table E-1 Generator Set Parts List Figure E-4 OHV110E Wiring Diagram Figure E-5 OHV100E Generator Output Wiring Diagram Figure E-6 OHV110E DC Wiring Diagram Baldor District Offices Baldor Generators