Chicago Electric 92456 operating instructions Generator USE and Care, Service

Page 5

GENERATOR USE AND CARE

1.Make sure the Power Switch is in its “OFF” position and disconnect the spark plug wire before making any adjustments, changing accessories, or storing the generator. Such preventive safety measures reduce the risk of starting the generator accidentally.

2.Store idle generators out of reach of children and other untrained persons. Generators are dangerous in the hands of untrained users.

3.Maintain generators with care. Do not use a damaged generator. Tag damaged generators “Do not use” until repaired.

4.Check for misalignment or binding of moving parts, breakage of parts, and any other condition that may affect the generator’s operation. If damaged, have the generator serviced before using. Many accidents are caused by poorly maintained generators.

5.Use only accessories that are recommended by the manufacturer for your model. Accessories that may be suitable for one generator may become hazard- ous when used on another generator.

SERVICE

1.Maintain labels and nameplates on the Generator and Engine. These carry important information. If unreadable or missing, contact Harbor Freight Tools for a replacement.

2.Generator service must be performed only by qualified repair personnel. Service or maintenance performed by unqualified personnel could result in a risk of injury.

3.When servicing a generator, use only identical replacement parts. Follow instructions in the “Inspection, Maintenance, And Cleaning” section of this manual. Use of unauthorized parts or failure to follow maintenance instructions may create a risk of electric shock or injury.

SKU 92456

For technical questions, please call 1-800-444-3353.

Page

Image 5
Contents Generator SET For technical questions and replacement parts, please callSKU For technical questions, please call Product SpecificationsSave this Manual Unpacking Electrical SafetyWork Area Read and Understand ALL InstructionsPersonal Safety Generator USE and Care ServiceHeart Pacemaker Precaution Installation Precautions Specific Product Warnings and PrecautionsFire and Explosion Precautions Chemical Precautions Mechanical PrecautionsRequired Minimum Extension Cord Gauge 120 Volt Noise PrecautionsElectrical Precautions General Location InstallationGenerator Support and Mounting Assembly Diagrams on pages 19Grounding the Generator Operating InstructionsFigure B To Start The Engine See Figure G Figure FSee Figure H, next Powering 120 Volt AC Tools And EquipmentSee Figure H INSPECTION, CLEANING, and MaintenanceDetails Engine Maintenance SchedulePlease Read the Following Carefully Parts ListAssembly Diagram Parts List 73A 72A 71A 77A 76A 70A 69A 75A 74A Wiring Diagram Owner’s Warranty Responsibilities Year WarrantyService and Maintenance O C h a r g e R e p a i r o r ReplacementLength of Coverage O n s e q u e n t i a l D a m a g e s Coverage

92456 specifications

The Chicago Electric 92456 is a versatile and powerful tool designed for a variety of woodworking projects, particularly known for its efficiency and user-friendly features. This compact router model is ideal for both professionals and hobbyists, providing an excellent balance of performance and affordability.

One of the standout features of the Chicago Electric 92456 is its robust 2.5 HP motor, which delivers ample power for demanding tasks. This motor supports variable speed settings, allowing users to adjust the RPM from 8,000 to 25,000. The ability to fine-tune the speed is essential for different applications, ensuring a clean and precise finish regardless of the material being routed.

The design of the Chicago Electric 92456 emphasizes ease of use and versatility. It comes with a soft-start feature that reduces the initial torque when the router is powered on, minimizing the chances of the tool jumping or causing uneven cuts. Additionally, the ergonomic handle design provides a comfortable grip, which helps to reduce fatigue during extended use, making it ideal for both amateurs and seasoned woodworkers.

This router is equipped with a dual LED work light, illuminating the work area to improve visibility and precision. This feature is particularly useful for detailed tasks or when working in environments with low lighting. The integrated dust collection port also plays a vital role in maintaining a clear workspace, enhancing both safety and cleanliness.

The Chicago Electric 92456 supports both 1/4-inch and 1/2-inch collets, enabling users to adapt the tool for various bits and applications. It also includes depth adjustment features for increased accuracy, ensuring that every cut meets the desired specifications.

In terms of construction, the router boasts a sturdy base that provides stability and balance during operation. This robust build is designed to withstand the rigors of frequent use, making it a reliable addition to any workshop.

Overall, the Chicago Electric 92456 is a well-rounded router that combines power, precision, and user-friendly features. Its adaptability and design make it an excellent choice for anyone looking to enhance their woodworking capabilities, whether for small home projects or larger professional endeavors.