Chicago Electric 98452 Installation, General Locations, SKU For technical questions, please call

Page 11

8.Keep all electrical equipment clean and dry. Replace any wiring where the in- sulation is cracked, cut, abraded, or otherwise degraded. Replace terminals that are worn, discolored, or corroded. Keep terminals clean and tight.

9.Insulate all connections and disconnected wires.

10.Guard against electric shock. Prevent body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerator enclosures.

11.Use only Class BC or Class ABC fire extinguishers on electrical fires.

INSTALLATION

1.NOTE: Prior to powering tools and equipment, make sure the Generator’s rated voltage, wattage, and amperage capacity (120V - 20 Amp’s) is adequate to supply all electrical loads that the unit will power. If powering exceeds the Generator’s capacity, it may be necessary to group one or more of the tools and/or equipment for connection to a separate Generator.

2.Electrical and other permits may be required for the installation of emergency or portable power systems. Investigate the local building and electrical codes before installing this unit. Installation must be completed by licensed contractors.

3.WARNING: The Generator weighs 103.6 pounds. Use care and the proper lifting or hoisting equipment when moving it to the installation location. Always connect hoist lines to the Frame (41B) of the Generator.

GENERAL LOCATIONS

1.It is recommended to locate the Generator (outdoors only) where cooling air is readily available.

2.Install the Generator so that the air inlets and outlets are not blocked by obstruc- tions such as bushes, trees, or snow drifts. Locating it in the path of heavy winds or snowdrifts may require the placement of a barrier for protection. The air inlet, in normal weather conditions, should face the prevailing wind direction.

3.Install the Generator on a concrete slab or other area where rain drainage or flood waters can not reach it.

4.Generator placement should allow four feet of access to all sides for mainte- nance.

5.Place the Generator as close as possible to the electrical tools and equipment be- ing powered to reduce the length of extension cords.

6.If the Generator is located indoors the Engine exhaust must be ventilated to the outdoors using leakproof, heat resistant, flexible, metal, flex tubing.

SKU 98452

For technical questions, please call 1-800-444-3353.

Page 11

Image 11
Contents Portable Generator For technical questions or replacement parts, please callFor technical questions, please call SpecificationsSave this Manual Work Area General Safety RulesElectrical Safety UnpackingGenerator USE and Care Personal SafetyService For technical questions, please call Heart Pacemaker Precaution Installation Precautions Specific Safety Rules and PrecautionsUse only Engine manufacturer recommended fuel and oil Fire and Explosion PrecautionsKeep the Generator and surrounding areas clean at all times Chemical Precautions Mechanical PrecautionsElectrical Precautions Noise PrecautionSKU For technical questions, please call InstallationInsulate all connections and disconnected wires General LocationsSee Figure B This Unit can Power the Following ItemsGenerator Support and Mounting Grounding the GeneratorSee Figure B, next Operating InstructionsREV 09h See Figure E To Start The EngineSee Figure G To its OFF position. See Figure D Powering 120 Volt AC Tools and EquipmentSee Figure H INSPECTION, MAINTENANCE, and Cleaning Part Description Qty Parts ListPlease Read the Following Carefully Assembly Diagram Parts List Assembly Diagram Owner’s Warranty Responsibilities Limited 1 year warrantyConsequential Damages Coverage No Charge Repair or ReplacementService and Maintenance Length of Coverage

98452 specifications

The Chicago Electric 98452 is a powerful and versatile tool designed for both professional and hobbyist woodworkers. This band saw stands out due to its robust build and a combination of innovative features that enhance usability and performance. With a 9-inch throat depth and a 12-inch cutting height, it offers significant capacity for a range of cutting applications, allowing users to tackle intricate curves and thick materials with ease.

One of the key characteristics of the Chicago Electric 98452 is its strong 2.5-amp motor, which provides ample power to cut through different types of wood with precision. This motor supports variable speeds, enabling users to adjust the cutting speed according to the material's density. This flexibility is crucial for achieving accurate cuts, especially when working with softer woods or harder composites.

The saw features a lightweight and portable design, making it convenient for users who may need to move their equipment around a workshop or transport it to job sites. The solid steel frame ensures stability during operations, minimizing vibrations that can lead to inaccurate cuts. The base is sturdy and provides added safety, ensuring that the unit remains secure during use.

The Chicago Electric 98452 is equipped with a built-in work light that illuminates the cutting area, improving visibility for detailed work. Additionally, its adjustable blade guides assist in maintaining blade alignment, which is essential for achieving clean, precise cuts consistently.

Another significant advantage of the Chicago Electric 98452 is its ease of blade changes. The saw is designed with tool-free blade tension adjustment, allowing users to swap out blades quickly and without hassle. This feature saves time and ensures that users can keep the right blade engaged for their specific project needs.

Safety features are also a priority in the design of the Chicago Electric 98452. It includes a safety switch to prevent accidental start-ups and a blade guard that protects users from potential hazards.

Overall, the Chicago Electric 98452 band saw is an excellent choice for those seeking a reliable, powerful, and user-friendly tool. Its combination of impressive features, effective technologies, and thoughtful characteristics makes it a valuable addition to any woodworking arsenal, suitable for both novice and experienced woodworkers alike.