a)Start the generator and adjust the spear valve to obtain 220-240 volts, 0 amps at the panel. [Do not turn the circuit breaker on].

b)Adjust the potentiometer on the circuit board very slowly to the left. When you detect a small decrease in voltage, stop. Turn on the circuit breaker and increase water to increase power to the unit. Increase power until a load of 2kW is indicated (P =VI).

c)If adjusting the potentiometer does not correct the problem, then contact PowerPal. The problem is probably with the potentiometer.

TECHNICAL SPECIFICATIONS

 

 

MHG-T2

1

Rated power output

2000W

2

Maximum allowable load

2200W

3

Intended voltage

220V~

4

Frequency at rated power output

50 Hz

5

Frequency at runaway speed

70 Hz

6

Runaway speed

1500rpm

7

Height

600mm

8

Weight

90kg

9

Turbine runner type

Turgo

10

Runner diameter

270mm

11

Number of buckets

20

12

Number of nozzles

1

13

Generator

3- phase

14

Generator insulation

Class B

15

Protection grade

IP54

16

Load controller circuit breaker

20A

17

Upper generator bearing size

6206-2Z

 

Lower generator bearing size

SKF 7206B

 

Turbine bearing size

SKF 1207

18

Seal size

38x58x10mm

19

Recommended cable

4mm2

20

Operating temperature

5 to 50 ° C

21

Operating humidity

0 to 90%

Notes:

1,2. Rated power output is the manufacturer’s specified output for the given head and flow conditions. A higher output is possible if the head is greater or the flow is faster than recommended. If the maximum allowable load is exceeded then permanent damage to the stator may occur.

3.Is approximately 220V when the ELC is used.

5,6. Runaway speed is the speed of the rotor if no load is applied. This speed is reduced under load.

18.We recommend SKF brand or similar high quality bearings.

Also, the diagrams and much useful information on pages 7 and 16 are taken from Micro-hydropower Sourcebook – A Practical Guide to Design and Implementation in Developing Countries. NRECA, 1986.

PowerPalT2 Turgo 15

Image 15
Contents Models MHG-T2 Safety First Read this FirstOperating Cautions System Diagram Powerpal ComponentsForebay, or water Measuring Gross Head Selecting a SiteSite Preparation Measuring FlowPowerPal T2 Turgo System Installation Mechanical AspectsElectrical Aspects ABC Hydro turbineOperation Greasing the Bearings Care and MaintenanceChanging the Bearings and Seal Troubleshooting Power output has been falling recently MHG-T2 Technical SpecificationsAppendix a Forebay Design Output watts Powerpal T2 Turgo Models