Chicago Electric 92455 manual Specific Product Warnings and Precautions

Page 6

SPECIFIC PRODUCT WARNINGS AND PRECAUTIONS

HEART PACEMAKER PRECAUTION

1.WARNING! People with pacemakers should consult their physician(s) be- fore using this product. Electromagnetic fields in close proximity to a heart pace- maker could cause interference to or failure of the pacemaker.

INSTALLATION PRECAUTIONS

1.Ensure installation meets all applicable safety, and local and national electrical codes. Have installation performed by a qualified, licensed electrician and building contractor.

2.All electrical work, including the earth-ground connection, should be completed by a licensed electrician.

3.Any separate fuel storage Generator supply facility must be built or installed in full compliance with all relevant local, state, and federal regulations.

4.If the generator is installed indoors, exhaust fumes must be piped out of the building using leak-free, heat-resistant piping. Use the Generator only in well ventilated outdoor areas. Carbon monoxide fumes are a color- less, odorless gas that, if inhaled, can cause serious injury or death. Pipes and silencer should not use any flammable materials, nor should they be installed near the same. Generator exhaust fumes must be within legal limits.

5.If the generator is installed outdoors, it must be weatherproofed and should be soundproofed. It should not be run outdoors without protection to the Generator and wiring conduit.

6.Never lift the Generator using the engine or alternator lifting lugs. Connect lifting equipment to the Frame of the Generator.

7.Before lifting the Generator, ensure the lift rigging and supporting structure are in good condition, and are rated to lift such a load.

8.Keep all personnel away from the suspended generator while relocating.

9.The supporting floor/ground surface should be level, and strong enough to safely hold the weight of the Generator. If the floor/ground surface is not level, strong cross members should be placed under the full length of the Generator Frame at its low side.

SKU 92455

For technical questions, please call 1-800-444-3353.

Page

Image 6
Contents For technical questions and replacement parts, please call Generator SETProduct Specifications Save this ManualSKU For technical questions, please call Unpacking General Safety RulesElectrical Safety Work AreaPersonal Safety Service Generator USE and CareSpecific Product Warnings and Precautions Heart Pacemaker Precaution Installation PrecautionsFire and Explosion Precautions Mechanical Precautions Chemical PrecautionsNoise Precautions Electrical PrecautionsInstallation General LocationGrounding the Generator Assembly Diagrams on pages 19Generator Support and Mounting Operating InstructionsFigure B Figure D REV 03/06 SKU For technical questions, please callFigure F See Figure GPowering 120 Volt AC Tools And Equipment See Figure H, nextINSPECTION, CLEANING, and Maintenance See Figure HEngine Maintenance Schedule Do not use damaged equipmentParts List Please Read the Following CarefullyAssembly Diagram Parts List 73A 72A 71A 77A 76A 70A 69A 75A 74A Wiring Diagram Year Warranty Owner’s Warranty ResponsibilitiesLength of Coverage O C h a r g e R e p a i r o r ReplacementService and Maintenance O n s e q u e n t i a l D a m a g e s Coverage

92455 specifications

The Chicago Electric 92455 is a premier power tool designed for both the novice DIY enthusiast and the seasoned professional. This versatile tool integrates a variety of features that enhance its functionality, making it a valuable addition to any workshop.

One of the standout characteristics of the Chicago Electric 92455 is its robust 8-inch wet tile saw capability. With its powerful 1.5 horsepower motor, it can handle tough materials with ease, providing efficient and precise cuts. This saw is particularly useful for cutting ceramic, porcelain, and glass tiles, thanks to its sharp and durable diamond blade. The adjustable cutting head allows users to perform both 45-degree and straight cuts, adding to its versatility when working on different projects.

The Chicago Electric 92455 incorporates advanced water cooling technology, which ensures that the tile saw remains at optimal temperatures during operation. This helps eliminate the risk of overheating and extends the lifespan of the blade, allowing for clean and accurate cuts without the risk of cracking or damaging the tile. The integrated water reservoir feeds water directly onto the blade, reducing dust and debris, which not only keeps the work area cleaner but also enhances visibility for users.

Another noteworthy feature is the built-in measuring guide and adjustable table. The guide helps users achieve precise measurements for repetitive cuts, while the adjustable table provides added stability and support for larger tiles. This combination ensures that even large-format tiles can be cut efficiently and quickly.

Safety is also a priority with the Chicago Electric 92455. The saw includes features such as a blade guard for protection and a secure locking switch to prevent accidental activation. These safety measures are essential when working with heavy-duty power tools, making it easier for users to focus on their projects.

In summary, the Chicago Electric 92455 stands out in the realm of tile saws for its powerful motor, water cooling technology, and robust safety features. Its versatility, coupled with ease of use, makes it an excellent choice for anyone tackling tile cutting projects, whether at home or in a professional setting. With this tool, users can expect reliable performance and high-quality results that will elevate their craftsmanship to new heights.