Chicago Electric 93881 operating instructions INSPECTION, MAINTENANCE, and Cleaning, See Figure G

Page 15

9.Once the Engine is running, simply connect the 120 volt appliances, tools, and equipment into the 120V AC Outlets (4) and/or connect a 12 volt appliance, tool, or equipment into the 12V DC Outlet (8). (See Figure E.)

10.IMPORTANT: If Engine speed or voltage fluctuates with a load below 250 Watts, move the Engine Choke Lever to the “HALF-CHOKE”position.

(See Figure G.)

11.When finished using the Generator, disconnect all electrical loads. Turn the Engine Power Switch (14) to its “OFF” position to stop the Engine. Then, close the Engine Fuel Valve Lever. (See Figures E and F.)

INSPECTION, MAINTENANCE, AND CLEANING

1. WARNING! Always make sure the Power Switch (14) of the Engine is in its “OFF” position prior to performing any service, maintenance, or cleaning of the

Generator or Engine. (See Figure E.)

2.Before each use, inspect the general condition of the Generator and Engine. Check for loose screws, misalignment or binding of moving parts, cracked or broken parts, loose hose connections, and any other condition that may affect the safe operation of the Generator and Engine. If abnormal noise or vibration occurs, have the problem corrected before further use.

Do not use damaged equipment.

3.Generator maintenance: Keep the Generator clean and dry at all times. The Generator should not be operated or stored in locations that include excessive moisture, dust, flammable or corrosive vapors. If these substances are on the Generator, clean with a cloth or soft brush. Do not use a garden hose or anything with liquid to clean the Generator. Liquid may enter the cooling air slots and could damage the interior workings of the Generator.

4.Engine maintenance: Refer to the Engine manufacturer’s “Operation, Maintenance, and Parts” manual (included) for detailed information about starting, running, stopping, and maintaining the Engine.

5.When storing the Generator, make sure to store the unit in a clean, dry, safe location out of reach of children and other unauthorized people.

6. CAUTION! All maintenance, service, or repairs not mentioned in this manual must only be performed by a qualified service technician.

SKU 93881 For technical questions, please call 1-800-444-3353 PAGE 15

Image 15
Contents Generator Your Warranty Is Voided IfWork Area Product SpecificationsGeneral Safety Rules and Precautions Save this ManualPersonal Safety Service Specific Safety Rules and PrecautionsFire and Explosion Precautions Mechanical PrecautionsUse only Engine manufacturer recommended fuel and oil Chemical Precautions Noise PrecautionsElectrical Precautions Figure a MISC. PrecautionsSee Figure B Assembly InstructionsUnpacking To Add Engine OilInstallation To Fill The Fuel TankSee Figure C General Location Grounding The GeneratorSee Figure D See Figure E Product FeaturesOperating Instructions Figure F To Start The Engine/GeneratorVolts x AMP = Watts example 120 volts x 3 AMPs = 360 Watts To Connect Electrical LoadsINSPECTION, MAINTENANCE, and Cleaning See Figure GDo not use damaged equipment Please Read the Following Carefully TroubleshootingDescription Qty Parts List & Assembly Diagram Control Panel13A 12A 11A 10A 8A Parts List & Assembly Diagram Generator AssyParts List & Assembly Diagram BODY/FUEL Tank Assy Generator