Siemens 410 S, 420 S manual Space If !strcasecmpa, sendonly sendonly=1 Continue

Page 25

Music on Hold (MOH)

Execution of Call Pickup

This is the modified source code:

sdpLineNum_iterator_init(&iterator);

while ((a = get_sdp_iterate(&iterator, req, "a"))[0] != '\0') { char* mimeSubtype = ast_strdupa(a); /* ensures we have enough

space */

if (!strcasecmp(a, "sendonly")) { sendonly=1;

continue;

}

/* condition added by VGarroy to test MOH */ if (!strcasecmp(a, "inactive")) {

sendonly=1;

continue;

}

if (!strcasecmp(a, "sendrecv")) { sendonly=0;

}

if (sscanf(a, "rtpmap: %u %[^/]/", &codec, mimeSubtype) != 2) continue;

if (debug)

ast_verbose("Found description format %s\n", mimeSubtype);

/* Note: should really look at the 'freq' and '#chans' params

too */

ast_rtp_set_rtpmap_type(p->rtp, codec, "audio", mimeSubtype);

if (p->vrtp) ast_rtp_set_rtpmap_type(p->vrtp, codec, "video",

mimeSubtype);

}

To compile the changes into the system, complete the following steps:

1.Go to the folder containing the source files (default: /usr/src/asterisk/).

2.Execute the commands make and make install.

30. June 2006

25

optiPoint 410/420 - Using with Asterisk, Configuration Guide

Image 25
Contents HiPath OptiPoint 410 S / 420 S Using with Asterisk Music on Hold MOH 9 Reference List 10 Sample Configuration Overview 2 System Requirements Configuration of AsteriskOverview Configuration of AsteriskSystem Requirements OverviewSIP Registration Sample configurationSyntax ExampleBindaddr BindportAllow QualifyExample Second User/Telephone Example First User/TelephoneType UsernameSyntax Dial PlanExplanations for lines 1 and 2 in the example Basic Configuration of optiPoint Telephones Basic Configuration of optiPoint TelephonesWeb Interface DialSIP/10,5,rBasic Configuration of optiPoint Telephones Network IP and routing General InformationLan Port setting Quality of ServiceSIP environment Network IP Address and Routing Terminal hostname DhcpQuality of Service SIP Environment Phone number New SIP password / Confirm SIP passwordSIP Port SIP server typeVoicemail number Multi LineVoicemail Settings in voicemail.confVoicemail ExplanationU10@myphones / b10@myphones User1@mail.comExten = 99,1,VoiceMailMain Settings in the file sip.confVoiceMailMain Notifymimetype=text/plainSetting up the Message Key on the optiPoint Telephone Group Definition Call PickupExecution of Call Pickup Pickup10&11 Music on Hold MOH Music on Hold MOHSdpLineNumiteratorinit&iterator Space If !strcasecmpa, sendonly sendonly=1 Continue Reference List Sample Configuration Sample ConfigurationSip.conf Myphones Exten = 10,1,DialSIP/10,5,r Extensions.confExten = 99,1,VoiceMailMain Exten = *8.,1,Pickup10&11 Voicemail.conf
Related manuals
Manual 10 pages 27.79 Kb

410 S, 420 S specifications

Siemens has long been a frontrunner in providing innovative industrial automation solutions, and the Siemens 410 S and 420 S models are exemplary products in their lineup. These advanced automation systems are designed to offer enhanced operational efficiency, flexibility, and reliability for various industrial applications.

The Siemens 410 S is primarily aimed at applications that require compact design coupled with powerful performance. It features a modular architecture, which allows for easy upgrades and customization according to specific needs. The control system is designed with integrated safety features, ensuring that operations are not only efficient but also secure. With support for various communication protocols, including PROFINET and PROFIBUS, the 410 S ensures seamless integration into existing systems, enabling smooth data exchange and interoperability.

On the other hand, the Siemens 420 S targets more complex automation requirements, featuring enhanced processing capabilities and expanded input/output options. This model offers advanced diagnostic features, allowing for real-time monitoring and troubleshooting, which significantly reduces downtime. Furthermore, the 420 S supports high-speed processing and extensive data handling, making it suitable for demanding applications such as robotics and high-speed assembly lines.

Both models are equipped with Siemens’ cutting-edge technology, including the TIA Portal (Totally Integrated Automation) software, which streamlines configuration, programming, and diagnostics. The intuitive user interface simplifies the automation process, enabling engineers to implement systems more rapidly and efficiently. Moreover, they are designed with energy efficiency in mind, contributing to sustainable operations by minimizing energy consumption.

Another noteworthy characteristic of the Siemens 410 S and 420 S is their robustness and durability. Constructed with high-quality materials, these models are built to withstand the rigors of industrial environments, ensuring that they can operate effectively in a range of conditions.

In summary, the Siemens 410 S and 420 S models represent the pinnacle of modern automation technology. With their modular designs, integrated safety features, advanced diagnostic capabilities, and compatibility with TIA Portal, they are well-equipped to meet the evolving demands of today’s industries. Whether for compact operations or complex processes, both models deliver the performance and reliability that businesses require in an ever-competitive market.