Siemens 420 S Example First User/Telephone, Example Second User/Telephone, Type, Username, Secret

Page 6

Configuration of Asterisk

SIP Registration

Example First User/Telephone:

[10]

type=friend

context=myphones

username=10

secret=123456

host=dynamic

Example Second User/Telephone:

[11]

type=friend

context=myphones

username=11

secret=123456

host=dynamic

Explanations:

type

Three types are available: peer, user and friend. For telephones (i.e. user agents) you have to enter friend.

context

The section in extensions.conf that is valid for the particular user, has to be labelled with the value used here; in the example: [myphones].

username

This parameter is only necessary if the user name contacted by Asterisk in case of an in- coming call is different from the registered user name or if the user is not registered. The user is registered under the name or the number heading the section.

secret

This is the password the user needs to register at the SIP server. If you do not want the save the password in plain text, you can use md5secret instead of secret and use the MD5 hash of a string consisting of the user name, realm and password for the value. In this case, the following steps have to be completed:

6

30. June 2006

optiPoint 410/420 - Using with Asterisk, Configuration Guide

Image 6
Contents HiPath OptiPoint 410 S / 420 S Using with Asterisk Overview 2 System Requirements Configuration of Asterisk Music on Hold MOH 9 Reference List 10 Sample ConfigurationSystem Requirements Configuration of AsteriskOverview OverviewSyntax Sample configurationSIP Registration ExampleAllow BindportBindaddr QualifyType Example First User/TelephoneExample Second User/Telephone UsernameDial Plan SyntaxExplanations for lines 1 and 2 in the example Web Interface Basic Configuration of optiPoint TelephonesBasic Configuration of optiPoint Telephones DialSIP/10,5,rBasic Configuration of optiPoint Telephones General Information Network IP and routingQuality of Service Lan Port settingSIP environment Network IP Address and Routing Dhcp Terminal hostnameQuality of Service SIP Environment SIP Port New SIP password / Confirm SIP passwordPhone number SIP server typeMulti Line Voicemail numberVoicemail Settings in voicemail.confVoicemail ExplanationUser1@mail.com U10@myphones / b10@myphonesVoiceMailMain Settings in the file sip.confExten = 99,1,VoiceMailMain Notifymimetype=text/plainSetting up the Message Key on the optiPoint Telephone Call Pickup Group DefinitionExecution of Call Pickup Pickup10&11 Music on Hold MOH Music on Hold MOHSdpLineNumiteratorinit&iterator Space If !strcasecmpa, sendonly sendonly=1 Continue Reference List Sample Configuration Sample ConfigurationSip.conf Exten = 99,1,VoiceMailMain Exten = *8.,1,Pickup10&11 Extensions.confMyphones Exten = 10,1,DialSIP/10,5,r Voicemail.conf
Related manuals
Manual 10 pages 27.79 Kb

410 S, 420 S specifications

Siemens has long been a frontrunner in providing innovative industrial automation solutions, and the Siemens 410 S and 420 S models are exemplary products in their lineup. These advanced automation systems are designed to offer enhanced operational efficiency, flexibility, and reliability for various industrial applications.

The Siemens 410 S is primarily aimed at applications that require compact design coupled with powerful performance. It features a modular architecture, which allows for easy upgrades and customization according to specific needs. The control system is designed with integrated safety features, ensuring that operations are not only efficient but also secure. With support for various communication protocols, including PROFINET and PROFIBUS, the 410 S ensures seamless integration into existing systems, enabling smooth data exchange and interoperability.

On the other hand, the Siemens 420 S targets more complex automation requirements, featuring enhanced processing capabilities and expanded input/output options. This model offers advanced diagnostic features, allowing for real-time monitoring and troubleshooting, which significantly reduces downtime. Furthermore, the 420 S supports high-speed processing and extensive data handling, making it suitable for demanding applications such as robotics and high-speed assembly lines.

Both models are equipped with Siemens’ cutting-edge technology, including the TIA Portal (Totally Integrated Automation) software, which streamlines configuration, programming, and diagnostics. The intuitive user interface simplifies the automation process, enabling engineers to implement systems more rapidly and efficiently. Moreover, they are designed with energy efficiency in mind, contributing to sustainable operations by minimizing energy consumption.

Another noteworthy characteristic of the Siemens 410 S and 420 S is their robustness and durability. Constructed with high-quality materials, these models are built to withstand the rigors of industrial environments, ensuring that they can operate effectively in a range of conditions.

In summary, the Siemens 410 S and 420 S models represent the pinnacle of modern automation technology. With their modular designs, integrated safety features, advanced diagnostic capabilities, and compatibility with TIA Portal, they are well-equipped to meet the evolving demands of today’s industries. Whether for compact operations or complex processes, both models deliver the performance and reliability that businesses require in an ever-competitive market.