SECTION 2

GENERAL INFORMATION

Rl Measurement

The Rl part of the LTL2000S(Q) Retroreflectometer measures the Rl (coefficient of retro re- flected luminance) parameter. The Rl parameter represents the brightness of the road mark- ings seen by drivers of motor vehicles by headlight illumination.

The illumination angle is 1.24° and the observation angle is 2.29°simulating a drivers view- ing distance of 30 metres at an eye height of 1.2 metres. The observation area is app. 45 mm. x 200 mm.

The optical specification complies with EN1436. The spectral sensitivity is eye matched us- ing SMART optical filter designed and produced by DELTA. The functional layout of the LTL2000S(Q) Rl optical system is shown in figure 3 below.

A very efficient electronic stray light compensation eliminates false signals from daylight.

102

101

104

103

106105

101 Light source

102 Receiver and spectral matching filter

103 Illumination aperture stop

104 Observation aperture stop

105 Illumination beam

106 Observation beam

107 Collimating lens

108Mirror

109Beam splitter

110Road marking surface

111Illumination field

112Observation field

107

108

109

110

112

111

 

 

Figure 3: LTL2000S(Q) RL optical system layout

DELTA

LTL2000S(Q) Retroreflectometer

11

Image 15
Contents LTL2000S / SQ Retroreflectometer Disclaimer Index Specification LTL2000S IntroductionLTL2000SQ features Measuring Getting started ButtonsWet night measurement considerations HomeScroll Keys Rl Calibration Calibration LTL2000SDisplay shows Step Calibration LTL2000SQ Calibrate Qd Calibration Rl Calibration How to place the calibration normalsRemember LTL2000SQ RL optical system layout Rl MeasurementDelta A road marking 500 400 300 200 100 Up to 5 mm profile height Up to 20 cm profile gap Qd Measurement 516 517 512 Factory calibration Instrument functionDelta Keyboard Layout Keyboard functionsKey Label Key Function Measurement id Clear log dataMenu system Qd ModeRl Mode Mean CalculationQd Signal VBat Qd Qd Stray LPrint Log Disable IdDefault Settings Off TimerBattery General careProtection window Rl calibration unit Ceramics FusesLamp Calibration unitRl calibration unit Light trap Light trapPrinter How to replacing the printer paperRS-232C specification LTL DTE Data protocol Command format Following commands have been defined Command setTEST2 Command Parameter Response Appendix B Result Printout Rl Calibration PrintoutQd Calibration Printout Log Printout Qd Calibration data Qd measurement data Status PrintoutGeneral Characteristics Qd General Characteristics RlElectrical Characteristics