Processor/Cache | |
Processors Supported | Intel® Pentium® III processors with up to |
| 512-KB of integrated L2 cache. |
| For the latest processor support,visit: |
| http://support.intel.com/support/ |
| motherboards/server |
| |
System Memory | |
Memory Capacity | Six DIMM sockets for up to 6 GB of PC133 |
| SDRAM (64 MB to1GB DIMMs supported; |
| memory must be populated in pairs) |
Memory Type | PC/133 registered SDRAM 72-bit ECC, |
| 168-pin gold-plated DIMMs |
DIMM Sizes | 64 MB,128 MB,256 MB, 512 MB, 1 GB |
Memory Voltage | 3.3V only |
Error Detection | Corrects single-bit errors, detects |
| double-bit errors (using ECC memory) |
| |
Integrated On Board | |
Chipset | ServerWorks*Enterprise ServerSet*III HESL |
Ultra160 SCSI Controller Adaptec* AIC7899 Dual Channel—two Ultra160/LVD channels (connect via one internal 68-pin wide connector, and one 68-pin high-density external SCSI connector)
Maximum data transfer: 160 MB/sec on each Ultra160/LVD channel
ATA/100 RAID Controller Promise Technologies*PDC20267 ATA/100 IDE RAID controller provides two channels of ATA/100 IDE that can be configured into either RAID level 0 or RAID level 1
| Maximum data transfer:100 MB/sec |
| on each ATA/100 channel. |
Intel® Server Adapter | Two Intel® PRO/100+ Fast Ethernet |
| Controllers (Intel® 82550PM) |
| Supports 10BASE-T and 100BASE-TX, |
| RJ45 output |
Graphics | ATI* Rage*XLSVGA PCI video controller |
| with 8 MB of video memory |
Super I/O Controller | National* PC97317* |
Input/Output Features | | |
PCI | Triple Peer PCI, up to six PCI slots on |
| risers in a 2U system |
| ● | Bus A: 32-bit/33-MHz |
| ● | Bus B: 64-bit/66 MHz |
| ● | Bus C: 64-bit/66-MHz |
IDE | One EIDE channel for a total of two IDE |
| devices |
USB | Two stacked USB connectors |
Serial ports | External RJ45 serial, Internal COM1 header |
Floppy Controller | 1.44 MB, 2.88 MB, 3-mode support |
Keyboard/Mouse | PS/2, 8240A-compatible |
Server Management Features1
Remote Management Remote access to system status, logs, configuration data, and utilities–without a remote management card
Event filtering and alerting through proactive LAN and mobile devices
System Monitoring | System health indicators and corrective |
and Auto-recovery | actions including: |
| ● | Automated power cycling |
| ● | OS watchdog timer |
| ● | Fault-resilient booting |
Server Troubleshooting Continuous health monitoring, text console redirection, and error logs
Operating Systems Microsoft* Windows* 2000, Microsoft*
SupportedWindows NT*, Red Hat* Linux*, SCO UnixWare*, and Novell* NetWare*
System BIOS | |
BIOS Type | 8 MB Flash EEPROM with AMI* BIOS, |
| Multi-boot BBS (BIOS Boot Specification) |
| 1.4-compliant |
Special Features | Plug and Play, IDE drive auto-configure, |
| SMBIOS 2.3, ECC/Parity support, |
| multilingual support |
Configuration Utilities | System Set-up Utility (SSU) enables |
| easy system setup of BIOS and utilities, |
| Plug and Play |
Jumpers and Front Panel Connectors
Front Panel Connectors | Power LED,power on/off switch, reset |
Jumpers | CMOS clear, password clear, BMC boot |
| write protect, BIOS recovery |
| |
Mechanical | |
Server Board Style | SSI Thin E-Bay |
Server Board Size | 12" x 13" |
|
Server Board Power Requirements |
+5V | 7.06A maximum continuous current |
+5V standby | 1.54A minimum continuous current |
+12V | 5.0A maximum continuous current |
+3.3V | 12.0A maximum continuous current |
-5V | 0 maximum continuous current |
-12V | 0.25A maximum continuous current |
| |
Environment | |
Ambient Temperature2 | Operating (system): 10°C to +35°C |
| Non-operating/storage (system): |
| -40°C to +70°C ambient |
Relative Humidity | Non-operating: 95%, non-condensing |
| @ 30°C |
| |
Product Regulations | |
Safety Compliance: | |
| UL/CUL 950-CSA 950 (UL |
Europe/Russia | Recognition Mark) |
EN60950; CE Mark-EU Directive |
International | 73/23/EEC; GOST-R Mark |
IEC60950 |
EMI Verification—configured in a compatible3 Intel host system
U.S. | Verified to FCC, Class A |
Canada | Verified to ICES-003, Class A |
Europe/Russia | Verified to EN55022 (Class A) and |
| EN55024 (CE Mark—EU Directive |
| 89/336/EEC)/GOST-R Mark |
International/Japan | Verified to CISPR-22/VCCI, Class A |
Australia/New Zealand | Verified to AS/NZS 3548, Class A |
| (C-tick Mark) |
Recommended Configurations and Order Codes
The following table provides several suggested configurations for 1U and 2U systems. Please visit www.intel.com/go/serverbuilder for the most recent product updates. | | |
| | | | | | | | |
| | 1U System with Integrated SCSI | | 1U System with | | 2U System with Integrated SCSI | | 2U System with |
| | | | Integrated ATA/100 RAID | | | | Integrated ATA/100RAID |
Intel® Server Board SCB2 | | SCB2SCSI | | SCB2ATA | | SCB2SCSI | | SCB2ATA |
| | | | | | | | |
Intel® Server Chassis SR1200 (1U rack) | | KCR5 | | KCR5 | | KSN5 | | Reference Chassis only4 |
or SR2200 (2U rack)4 | | | | | | | | |
Chassis Backplane (required) | | BCR1USBPWB | | BCR1UABPWB | | Included with chassis | | — |
| | | | | | | | |
Redundant Power Module (optional) | | N/A | | N/A | | AXX2PSMODL350 | | — |
Sliding Rails (optional) | | AXX1U2URAIL | | AXX1U2URAIL | | AXX1U2URAIL | | — |
| | | | | | | | |
CD-ROM/Floppy Module (optional) | | AXXCDFLOPPY | | AXXCDFLOPPY | | AXXCDFLOPPY | | — |
| | | | | | | | |
Locking Bezel (optional black or beige) | | ACRBEZBLACK or ACRBEZBEIGE | | ACRBEZBLACK or ACRBEZBEIGE | | ASNBEZBLACK or ASNBEZBEIGE | | — |
ICMB Board Assembly (optional) | | AXX2ICMBKIT | | AXX2ICMBKIT | | AXX2ICMBKIT | | AXX2ICMBKIT |
| | | | | | | | |
RJ45 to DB9 Serial Connector Converter | | AXXRJ45DB9 | | AXXRJ45DB9 | | AXXRJ45DB9 | | AXXRJ45DB9 |
| | | | | | | | |
Chassis Spares Kits | | FCRSPRKIT | | FCRSPRKIT | | FSNSPRKIT | | — |
Intel® RAID Controller SRCMR (modular ROMB)6 | | SRCMR | | — | | SRCMR | | — |
Intel® Server RAID Controller SRCU31L (low profile)6 | | — | | SRCU31L | | — | | SRCU31L |
Intel® PRO/1000 XT Server Adapter (low profile)6 | | PWLA8490XTL | | PWLA8490XTL | | PWLA8490XTL | | PWLA8490XTL |
| | | |
1.Full utilization of some server management features is dependent on the use of an Intel® server chassis.
2.Environment ambient temperature is the system intake measurement for an Intel® Server Board SCB2 installed in an Intel® Server Chassis SR1200.
3.Compatible host system denotes the system(s) with which Intel tested the board and found it compliant.
4.See http://support.intel.com for a complete list of Intel and third-party compatible chassis.
5.The order code listed is for a chassis with an AC power supply. See www.intel.com/go/serverbuilder for ordering information with respect to the –48V DC power supply.
6.See http://support.intel.com for a complete list of validated Intel and third-party adapter cards.
For the most current product information on Intel server building blocks, visit: www.intel.com/go/serverbuilder
All products, dates, and figures specified are preliminary based on current expectations, provided for planning purposes only, and are subject to change without notice. Availability in different channels may vary.
Information in this document is provided in connection with Intel® products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel® prod- ucts including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice.
Intel, Intel logo, and Pentium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. | |
*Other names and brands may be claimed as the property of others. | |
Copyright © 2001, Intel Corporation. | Intel Literature Center: 1-800-548-4725 |
0901/SJ/DMW/MD/PP/15K | ORDER NUMBER 283951-001 |