Watchdog Timer Registers
Address of register (2E) | Attribute |
|
|
|
|
Read/Write | Value (2F) and |
|
| description |
|
|
|
|
87 (hex) | Write this address to I/O | |
|
| address port 2E (hex) twice |
|
| to unlock theW83627HF |
|
|
|
07 (hex) | write | Write 08 (hex) to select reg- |
|
| ister of watchdog timer. |
|
|
|
30 (hex) | write | Write 01 (hex) to enable the |
|
| function of the watchdog |
|
| timer. Disabled is set as |
|
| default. |
|
|
|
F5 (hex) | write | Set seconds or minutes as |
|
| units for the timer. |
|
|
|
Write 0 to bit 3: set sec- |
|
|
ond as counting unit. |
|
|
[default] |
|
|
|
|
|
Write 1 to bit 3: set |
|
|
minute as counting unit |
|
|
|
|
|
F6 (hex) | write | 0: stop timer [default] |
|
| 01~FF (hex): The amount |
|
| of the count, in seconds or |
|
| minutes, depends on the |
|
| value set in register F5 |
|
| (hex). This number decides |
|
| how long the watchdog |
|
| timer waits for strobe |
|
| before generating an inter- |
|
| rupt or reset signal. Writing |
|
| a new value to this register |
|
| can reset the timer to count |
|
| with the new value. |
|
|
|
| 70 |