Intel AXXRSBBU6 manual Reinserting an add-in RAID Controller

Page 10

Caution: Center the screwdriver carefully to avoid stripping the screwhead. Do not over-tighten the screws. The maximum recommended torque is 2.25 inch pounds.

C. Place the Intel® RAID Controller back into the server

1.Align the RAID controller with the PCI Express* slot.

2.Press down gently, but firmly, to ensure that the RAID controller is properly seated in the slot. The bottom edge of the RAID controller must be flush with the slot.

Caution: Never apply pressure to the AXXRSBBU6 when you insert the RAID controller. Instead, press down only on the top edge of the RAID controller.

Figure 4. Reinserting an add-in RAID Controller

3.Attach the cables, as needed, to the connectors on the Intel® RAID controller.

For the Intel® Server Platform S7000FC4UR only: Install the processor air baffle.

4.Replace the computer cover and reattach the power cord(s).

.

6

Image 10
Contents AXXRSBBU6 Disclaimer Contents List of Figures List of TablesAbout the Intel RAID Smart Battery Important Safety Instructions Installing the AXXRSBBU6 Top and Bottom View of the AXXRSBBU6Important Pre-installation Considerations Step-by-step AXXRSBBU6 InstallationBattery alignment on the add-in Intel RAID Controllers Reinserting an add-in RAID Controller Monitoring Battery Backup Monitoring BBUs with the RAID Bios Configuration UtilityUsing Intel RAID Web Console BBU information in RWC2Replacing Battery Backup Units Disposing of Battery Backup UnitsBattery Backup Unit Specifications Battery Life and Data Retention Time