Intel AXXRSBBU6 manual Battery Backup Unit Specifications, Battery Life and Data Retention Time

Page 14

Battery Backup Unit Specifications

 

Table 1. Battery Backup Unit Specifications

 

 

Battery Technology

LiON (Lithium ION) 1 cell

 

10–45°C ambient temperature

Battery Operating Environment

20% to 80% humidity non-condensing

 

 

Depends on storage time,:< 30 days: 0–50 °C

Battery Storage Temperature

30–90 days: 0–40 °C ‘; > 90 days: 0–30 °C

 

 

 

Fast Charge Current

500mAH using charge circuitry card

 

 

Battery Voltage

Nominal OCV: 3.7 V

 

 

Mechanical

2.611 inches x 2.122 inches

 

 

Battery Capacity

700 mAH

 

 

Memory Technology

DDR2 SDRAM (1.8 V)

 

Typical: ~3 hours to charge from 1.8V OCV to 3.7V OCV

Battery Charge Time

Completely depleted: 8 hours

 

 

 

Battery Shelf Life

1 year

 

 

Battery Operational Life

Intel provides a 1 year warranty on the AXXRSBBU6.

 

 

Supported Cache Memory

128 - 512 Mbytes

 

 

Memory

DDR2 SDRAM 667 MHz (1.8V), max 40-bit bus width

 

 

MTBF (Electrical Components)

2,490,772 hours at 40° C

 

Temp monitoring via I2C interface. Supports v1.1 “Smart Battery

Smart Battery Monitoring

System Manager”

 

 

Ability to detect the presence of an external auxiliary power source.

 

Auxiliary Power

Circuitry automatically chooses aux power, defers discharge until aux

 

power is removed or exhausted. Auxpower increases the DRT ratings

 

 

Battery Life and Data Retention Time

The Intel utilities display a counter showing the number of times a BBU has been recharged. When you replace a BBU, you should run the utility program and reset this counter to zero for the new BBU. Intel recommends that you replace the battery pack on the BBU once a year or after 500 recharging cycles, whichever comes first. The warranty on the battery pack is for one year.

The data retention time is 72 hours (low power) if using the RAM shown below. This rating is approximate and can vary based on battery load, ambient temperature, and number of discharge cycles associated with the battery.

256 Mb using (3) 64Mx16 DDR2

128 Mb using (3) 32Mx16 DDR2

10

Image 14
Contents AXXRSBBU6 Disclaimer Contents List of Figures List of TablesAbout the Intel RAID Smart Battery Important Safety Instructions Installing the AXXRSBBU6 Top and Bottom View of the AXXRSBBU6Important Pre-installation Considerations Step-by-step AXXRSBBU6 InstallationBattery alignment on the add-in Intel RAID Controllers Reinserting an add-in RAID Controller Monitoring Battery Backup Monitoring BBUs with the RAID Bios Configuration UtilityUsing Intel RAID Web Console BBU information in RWC2Replacing Battery Backup Units Disposing of Battery Backup UnitsBattery Backup Unit Specifications Battery Life and Data Retention Time