Battery Backup Unit Specifications
| Table 1. Battery Backup Unit Specifications | |
|
| |
Battery Technology | LiON (Lithium ION) 1 cell | |
| ||
Battery Operating Environment | ||
20% to 80% humidity | ||
| ||
| Depends on storage time,:< 30 days: | |
Battery Storage Temperature | ||
| ||
|
| |
Fast Charge Current | 500mAH using charge circuitry card | |
|
| |
Battery Voltage | Nominal OCV: 3.7 V | |
|
| |
Mechanical | 2.611 inches x 2.122 inches | |
|
| |
Battery Capacity | 700 mAH | |
|
| |
Memory Technology | DDR2 SDRAM (1.8 V) | |
| Typical: ~3 hours to charge from 1.8V OCV to 3.7V OCV | |
Battery Charge Time | ||
Completely depleted: 8 hours | ||
| ||
|
| |
Battery Shelf Life | 1 year | |
|
| |
Battery Operational Life | Intel provides a 1 year warranty on the AXXRSBBU6. | |
|
| |
Supported Cache Memory | 128 - 512 Mbytes | |
|
| |
Memory | DDR2 SDRAM 667 MHz (1.8V), max | |
|
| |
MTBF (Electrical Components) | 2,490,772 hours at 40° C | |
| Temp monitoring via I2C interface. Supports v1.1 “Smart Battery | |
Smart Battery Monitoring | ||
System Manager” | ||
| ||
| Ability to detect the presence of an external auxiliary power source. | |
| ||
Auxiliary Power | Circuitry automatically chooses aux power, defers discharge until aux | |
| power is removed or exhausted. Auxpower increases the DRT ratings | |
|
|
Battery Life and Data Retention Time
The Intel utilities display a counter showing the number of times a BBU has been recharged. When you replace a BBU, you should run the utility program and reset this counter to zero for the new BBU. Intel recommends that you replace the battery pack on the BBU once a year or after 500 recharging cycles, whichever comes first. The warranty on the battery pack is for one year.
The data retention time is 72 hours (low power) if using the RAM shown below. This rating is approximate and can vary based on battery load, ambient temperature, and number of discharge cycles associated with the battery.
•256 Mb using (3) 64Mx16 DDR2
•128 Mb using (3) 32Mx16 DDR2
10