Lenovo 8332 manual Front operators panel, Connectors, Server board LEDs

Page 15
Connectors

1PS2 mouse port 2System status LED 3MSB (POST LED) 4Bit 1 (POST LED) 5Serial port 6NIC port 1 (1 Gb) 7NIC port 2 (1 Gb) 8PS2 keyboard

9Bit 2 (POST LED) 10LSB (POST LED) 11Video port 12USB port 2 13USB port 3 14USB port 1 15USB port 0

Connectors

The following connectors are located on the server board I/O panel:

vPS2 mouse port

vPS2 keyboard port

vSerial port

vVideo port

vTwo RJ-45 ports - NICs 1 and 2 (1Gb each)

vFour USB ports: 0, 1, 2, and 3

Server board LEDs

Status LEDs: Diagnostic LEDs are located on the server board I/O panel to assist in identifying failed and failing components. See “Server board LEDs” on page 25 for a summary of status LED states.

NIC LEDs: The NIC LEDs at the right and left of each NIC port provide information on NIC status. See “I/O panel NIC LEDs” on page 25 for a summary of NIC LED states.

Front operator's panel

A front operator’s panel, consisting of a USB port, three LEDs and three push-button switches, are located on the front of the enclosure.

Note: The front operator’s panel is an integral part of the enclosure assembly and is not field replaceable.

Figure 8. Front operator’s panel components

 

1USB port

5Power active LED

2Unit fault LED

6ID LED

Chapter 2. Features 7

Image 15
Contents Secure Managed Client Storage Array User Guide Machine TypePage Secure Managed Client - Storage Array User Guide Copyright Lenovo 2005, 2008. All rights reserved First Edition OctoberContents ivUser Guide Introduction Product contents, order options, and accessoriesviUser Guide Chapter 1. Important safety information 2User Guide Chapter 2. Features 4 Boot drive 5 Server board 6 PCI slotsFigure 1. SMC - Storage Array front view Enclosure subsystem Enclosure chassis Server board I/O panel Server board subdivisionConnectors Front operators panelServer board LEDs Rear panel Power supply unitCooling fans Power supply output connectorsFigure 10. Cooling fan Drive carrier module1Green LED 2Amber LED 3Torque screw Drive status indicatorAnti-tamperlocks 4Drive lock indicator opening12User Guide Planning your installation Chapter 3. Getting StartedDrive bay numbering convention Enclosure installation prerequisites Preparation of site and host serverUnpacking the enclosure system Planning and configuring your installation Rack installation prerequisitesFigure 14. Unpacking the SMC - Storage Array Installing the enclosure in a rack Rail kit assemblyEnclosure installation Grounding checks Power cord connection18User Guide Power on Power supply unit LEDChapter 4. Operation switch Front operators panel LEDs and switchesBlue only when activated Table 5. Front operators panel switch functionsActivating an anti-tamperlock Starting the drivesDisk drive LEDs Engaging the drive module anti-tamperlocksTurning off BIOS settingsAlarm sounds and power up Chapter 5. Troubleshooting and problem solvingInitial start-upproblems Faulty cordsLEDs Fault conditionCondition LED stateServer board LEDs Cooling fan LEDsDrive carrier module LEDs Rear panel LEDLED/buzzer Audible alarmsAlarm interpretation DescriptionMeaning Troubleshooting System faultsPower supply unit faults Table 15. Thermal cooling Cooling fan faultsThermal cooling Table 14. Cooling fan faultsDealing with hardware faults Drive carrier module faultsContinuous operation during replacement 32User Guide Attention Lenovo Director of Licensing Chapter 6. NoticesLenovo United States, Inc 1009 Think Place Building One Morrisville, NC USATrademarks Page 1P P/N 45K1342